10 practice questions on wiring systems — batten, casing and capping, cleat and conduit wiring: types, spacing rules and installation — with answers and explanations.
Q1. Cleats are usually fixed 30 cm apart, but the spacing must never exceed:
- (a) 30 cm
- (b) 60 cm
- (c) 90 cm
- (d) 120 cm
Answer: (b) 60 cm — 30 cm is the usual spacing and 60 cm is the maximum allowed; wider spacing is not up to standard.
Q2. Batten wiring uses which type of cable?
- (a) PVC conduit cable
- (b) CTS (Cab Tyre Sheathed) cable
- (c) Armoured cable
- (d) Mineral-insulated cable
Answer: (b) CTS (Cab Tyre Sheathed) cable — the sheathed cables are clipped onto wooden or PVC battens fixed on the wall.
Q3. In casing and capping wiring, what is the capping?
- (a) The grooved base channel
- (b) The flat cover screwed over the casing
- (c) The wire itself
- (d) The conduit fitting
Answer: (b) The flat cover screwed over the casing — the casing is the grooved base fixed to the wall, the capping is the cover.
Q4. Under the NEC, when 3 or more conductors are in a conduit, the wires must not fill more than what percentage of the conduit’s inside area?
- (a) 20%
- (b) 40%
- (c) 53%
- (d) 70%
Answer: (b) 40% — the 40% fill rule leaves room for heat to escape and for wires to be pulled without damage.
Q5. Using the 40% fill rule, how many 1.5 mm² wires fit in a 20 mm PVC conduit?
- (a) 6
- (b) 9
- (c) 13
- (d) 20
Answer: (c) 13 — the usable area is 96.2 mm² and one wire takes 7.07 mm², so 96.2 ÷ 7.07 = 13.6, i.e. 13 wires maximum.
Q6. Which wiring system is the cheapest and is used for temporary installations?
- (a) Conduit wiring
- (b) Cleat wiring
- (c) Casing and capping wiring
- (d) Concealed conduit wiring
Answer: (b) Cleat wiring — it is the cheapest system and is used for temporary wiring, not permanent modern home wiring.
Q7. How far apart should saddles be fixed on a straight surface-conduit run?
- (a) Every 2 m
- (b) Every 600 mm to 1 m
- (c) Every 100 mm
- (d) Every 3 m
Answer: (b) Every 600 mm to 1 m — closer spacing stops the conduit sagging; put a saddle near every bend and junction box.
Q8. Casing and capping wiring is used only for:
- (a) Outdoor exposed runs
- (b) Damp places
- (c) Dry indoor wiring
- (d) Underground runs
Answer: (c) Dry indoor wiring — it is not used in damp places or outdoor exposed runs.
Q9. Batten wiring is which type of wiring?
- (a) Concealed wiring
- (b) Surface wiring
- (c) Underground wiring
- (d) Overhead wiring
Answer: (b) Surface wiring — the cables run on the surface of the wall, fixed on battens.
Q10. Which conduit is the best choice for home wiring?
- (a) Metal conduit
- (b) PVC conduit
- (c) Flexible steel conduit
- (d) Lead-sheathed conduit
Answer: (b) PVC conduit — it is cheap, lightweight, corrosion-proof and easy to install; metal conduit is for factories and fire-risk areas.
Also read: Batten Wiring | Cleat Wiring System | Surface Conduit Wiring | All MCQ Topics