Fuse Size Calculator

Pick the right fuse for a load. A fuse must be bigger than the normal running current — but small enough to blow before the wire overheats. Motors need extra headroom for their starting surge.



Worked Examples

Example 1 — 8 A resistive load: fuse = 8 × 1.25 = 10 A. Use a 10 A fast-blow fuse.

Example 2 — 12 A motor: motors draw a big starting surge, so fuse = 12 × 1.5 = 18 A. Round up to a 20 A slow-blow (time-delay) fuse — a fast-blow fuse would pop every time the motor starts.

Example 3 — 15 A resistive load: fuse = 15 × 1.25 = 18.75 A. Round up to a 20 A fast-blow fuse.

Frequently Asked Questions

1. What is the fuse size formula?
Fuse amps = load current × 1.25 for resistive and electronic loads. For motors and other loads with a starting surge, use × 1.5 and a slow-blow fuse. Always round up to the next standard fuse size.

2. What is the difference between fast-blow and slow-blow fuses?
A fast-blow fuse opens the moment current exceeds its rating — right for heaters, lights and electronics. A slow-blow (time-delay) fuse tolerates a short surge of a few seconds — right for motors, compressors and switch-mode power supplies.

3. Can I use a bigger fuse to stop it blowing?
No. The fuse protects the wire and the equipment — a bigger fuse lets a fault cook the wire until it melts or catches fire. If a fuse keeps blowing, find the overload or the fault instead.

4. Why does my fuse keep blowing?
Usually an overload (too much load), a short circuit, a motor that cannot start (seized or low voltage), or the wrong fuse type — a fast-blow fuse on a motor will pop on every start.

5. Fuse vs circuit breaker — which is better?
A fuse is cheaper and faster on a heavy short circuit, but it must be replaced after it blows. A breaker can be reset, but costs more. Fuses are still common in electronics, cars and appliances; breakers protect house wiring.