Q1. A lamp does not light, but the same lamp works in another socket. What is the fault?

  • (a) The lamp is blown
  • (b) The first socket or its circuit is faulty — the lamp itself is proven good
  • (c) The breaker for the whole house is off
  • (d) The lamp is the wrong wattage

Answer: (b) The first socket or its circuit is faulty — the lamp itself is proven good — swapping a known-good lamp into the dead socket, or the suspect lamp into a good socket, isolates lamp from circuit.

Q2. All the lights in a house dim briefly when a large appliance starts. What is the most likely cause?

  • (a) The lamps are faulty
  • (b) Voltage drop from the heavy starting current — normal to a degree, but excessive dimming suggests a weak supply or loose main connection
  • (c) The breaker is too large
  • (d) The lamps are too bright

Answer: (b) Voltage drop from the heavy starting current — normal to a degree, but excessive dimming suggests a weak supply or loose main connection — a motor’s starting inrush briefly pulls the voltage down across the whole installation.

Q3. One lamp flickers while all the other lamps on the same circuit are steady. What should you check first?

  • (a) The main supply
  • (b) That lamp’s holder, its connections, and the lamp itself — the fault is local to that one fitting
  • (c) The meter
  • (d) The breaker rating

Answer: (b) That lamp’s holder, its connections, and the lamp itself — the fault is local to that one fitting — a fault affecting only one lamp cannot be in the shared supply.

Q4. An LED lamp flickers when used with an old dimmer switch. What is the most likely cause?

  • (a) The LED is blown
  • (b) The dimmer is not LED-compatible — old leading-edge dimmers do not work correctly with LED drivers
  • (c) The supply voltage is too high
  • (d) The circuit is overloaded

Answer: (b) The dimmer is not LED-compatible — old leading-edge dimmers do not work correctly with LED drivers — the fix is an LED-rated dimmer or a non-dimmable circuit.

Q5. A ceiling fan runs slowly and hums, even on its highest speed setting. What is the most likely cause?

  • (a) The fan is new
  • (b) The fan’s run capacitor has weakened, or the bearings are stiff — both reduce speed and cause humming
  • (c) The supply voltage is too high
  • (d) The fan blades are too clean

Answer: (b) The fan’s run capacitor has weakened, or the bearings are stiff — both reduce speed and cause humming — a weak capacitor cuts the running torque, and stiff bearings add drag.

Q6. A lamp glows dimly even when its switch is OFF. What is the most likely cause?

  • (a) The lamp is too powerful
  • (b) A small leakage current — for example a switch wired in the neutral, an illuminated switch, or induced voltage in a long cable run
  • (c) The breaker is tripped
  • (d) The lamp is blown

Answer: (b) A small leakage current — for example a switch wired in the neutral, an illuminated switch, or induced voltage in a long cable run — LEDs need very little current to glow, so even a tiny leakage shows.

Q7. A fan does not run at all, but you measure 230 V at the fan’s terminals. What is the fault?

  • (a) The supply to the house has failed
  • (b) The fault is inside the fan — its motor, capacitor, speed control or internal wiring
  • (c) The breaker is off
  • (d) The wall switch is faulty

Answer: (b) The fault is inside the fan — its motor, capacitor, speed control or internal wiring — 230 V reaching the terminals proves the supply and switch; the break is in the fan itself.

Q8. A new bulb blows within a day of being fitted, and the previous bulb also failed early. What should you check?

  • (a) The bulb brand only
  • (b) Overvoltage at the fitting, a loose holder causing arcing, or vibration — repeated early failure means a circuit fault, not bad luck
  • (c) The colour of the lampshade
  • (d) The time of day

Answer: (b) Overvoltage at the fitting, a loose holder causing arcing, or vibration — repeated early failure means a circuit fault, not bad luck — measure the voltage at the holder and check the contacts.

Q9. A fluorescent tube flickers at its ends and never fully lights. What is the most likely faulty part?

  • (a) The wall switch
  • (b) The starter or the tube itself — a worn starter cannot strike the tube, and a blackened tube is at end of life
  • (c) The main breaker
  • (d) The meter

Answer: (b) The starter or the tube itself — a worn starter cannot strike the tube, and a blackened tube is at end of life — replace the starter first, then the tube if the flicker continues.

Q10. A fan runs normally on high speed but not on low speeds. What does this indicate?

  • (a) The fan motor is burnt out
  • (b) The speed regulator or its connections are faulty — the motor itself works when given full voltage
  • (c) The supply has failed
  • (d) The capacitor is shorted

Answer: (b) The speed regulator or its connections are faulty — the motor itself works when given full voltage — a motor fault would affect all speeds, so the fault is in the speed control path.