Synchronous Motor MCQs — Set 8

10 practice questions on synchronous motor torque — load angle, pull-out torque and torque calculations with worked answers.

Q1. What is the load angle (torque angle) of a synchronous motor?

  • (a) The angle between the stator and rotor magnetic fields
  • (b) The angle of the rotor shaft
  • (c) The phase angle between voltage and current
  • (d) The angle between two stator phases

Answer: (a) The angle between the stator and rotor magnetic fields — the rotor field lags behind the stator field by this angle, which grows with load.

Q2. As the mechanical load on a synchronous motor increases, what happens to the load angle?

  • (a) It decreases
  • (b) It stays the same
  • (c) It increases
  • (d) It becomes zero

Answer: (c) It increases — the rotor falls further behind the stator field as it delivers more torque, while the speed stays synchronous.

Q3. What is the pull-out torque of a synchronous motor?

  • (a) The torque at no load
  • (b) The starting torque
  • (c) The maximum torque the motor can develop before losing synchronism
  • (d) The torque at unity power factor

Answer: (c) The maximum torque the motor can develop before losing synchronism — beyond this torque the rotor falls out of step.

Q4. For a cylindrical-rotor synchronous motor, pull-out torque occurs at approximately what load angle?

  • (a) 0 degrees
  • (b) 45 degrees
  • (c) 90 degrees electrical
  • (d) 180 degrees electrical

Answer: (c) 90 degrees electrical — power developed is proportional to sin δ, which is maximum at δ = 90°.

Q5. The power developed by a synchronous motor is proportional to what function of the load angle δ?

  • (a) cos δ
  • (b) sin δ
  • (c) tan δ
  • (d) δ squared

Answer: (b) sin δ — the torque-angle curve follows a sine wave, rising to a maximum at 90° and falling after that.

Q6. At no load, what is the load angle of a synchronous motor?

  • (a) 90 degrees
  • (b) Nearly zero
  • (c) 180 degrees
  • (d) 45 degrees

Answer: (b) Nearly zero — with no load to drive, the rotor field sits almost in line with the stator field; only friction and windage need a tiny angle.

Q7. If the load on a synchronous motor is increased beyond its pull-out torque, what happens?

  • (a) The motor speeds up
  • (b) The motor keeps running at synchronous speed
  • (c) The motor loses synchronism and falls out of step
  • (d) The motor reverses

Answer: (c) The motor loses synchronism and falls out of step — the rotor can no longer follow the stator field and the motor stalls or runs erratically.

Q8. A synchronous motor delivers 100 kW at 1,500 rpm. What is its shaft torque approximately?

  • (a) 318 N·m
  • (b) 477 N·m
  • (c) 637 N·m
  • (d) 955 N·m

Answer: (c) 637 N·m — ω = 2π × 1,500 ÷ 60 = 157.1 rad/s, so T = P ÷ ω = 100,000 ÷ 157.1 = 637 N·m.

Q9. A synchronous motor delivers 50 kW at 1,000 rpm. What is its shaft torque approximately?

  • (a) 318 N·m
  • (b) 477 N·m
  • (c) 637 N·m
  • (d) 159 N·m

Answer: (b) 477 N·m — ω = 2π × 1,000 ÷ 60 = 104.7 rad/s, so T = P ÷ ω = 50,000 ÷ 104.7 = 477 N·m.

Q10. Which of these increases the pull-out torque of a synchronous motor?

  • (a) Reducing the excitation
  • (b) Increasing the excitation
  • (c) Reducing the supply voltage
  • (d) Increasing the load angle beyond 90 degrees

Answer: (b) Increasing the excitation — a stronger rotor field raises the maximum torque the motor can develop before pull-out.