Synchronous Motor MCQs — Set 8
10 practice questions on synchronous motor torque — load angle, pull-out torque and torque calculations with worked answers.
Q1. What is the load angle (torque angle) of a synchronous motor?
- (a) The angle between the stator and rotor magnetic fields
- (b) The angle of the rotor shaft
- (c) The phase angle between voltage and current
- (d) The angle between two stator phases
Answer: (a) The angle between the stator and rotor magnetic fields — the rotor field lags behind the stator field by this angle, which grows with load.
Q2. As the mechanical load on a synchronous motor increases, what happens to the load angle?
- (a) It decreases
- (b) It stays the same
- (c) It increases
- (d) It becomes zero
Answer: (c) It increases — the rotor falls further behind the stator field as it delivers more torque, while the speed stays synchronous.
Q3. What is the pull-out torque of a synchronous motor?
- (a) The torque at no load
- (b) The starting torque
- (c) The maximum torque the motor can develop before losing synchronism
- (d) The torque at unity power factor
Answer: (c) The maximum torque the motor can develop before losing synchronism — beyond this torque the rotor falls out of step.
Q4. For a cylindrical-rotor synchronous motor, pull-out torque occurs at approximately what load angle?
- (a) 0 degrees
- (b) 45 degrees
- (c) 90 degrees electrical
- (d) 180 degrees electrical
Answer: (c) 90 degrees electrical — power developed is proportional to sin δ, which is maximum at δ = 90°.
Q5. The power developed by a synchronous motor is proportional to what function of the load angle δ?
- (a) cos δ
- (b) sin δ
- (c) tan δ
- (d) δ squared
Answer: (b) sin δ — the torque-angle curve follows a sine wave, rising to a maximum at 90° and falling after that.
Q6. At no load, what is the load angle of a synchronous motor?
- (a) 90 degrees
- (b) Nearly zero
- (c) 180 degrees
- (d) 45 degrees
Answer: (b) Nearly zero — with no load to drive, the rotor field sits almost in line with the stator field; only friction and windage need a tiny angle.
Q7. If the load on a synchronous motor is increased beyond its pull-out torque, what happens?
- (a) The motor speeds up
- (b) The motor keeps running at synchronous speed
- (c) The motor loses synchronism and falls out of step
- (d) The motor reverses
Answer: (c) The motor loses synchronism and falls out of step — the rotor can no longer follow the stator field and the motor stalls or runs erratically.
Q8. A synchronous motor delivers 100 kW at 1,500 rpm. What is its shaft torque approximately?
- (a) 318 N·m
- (b) 477 N·m
- (c) 637 N·m
- (d) 955 N·m
Answer: (c) 637 N·m — ω = 2π × 1,500 ÷ 60 = 157.1 rad/s, so T = P ÷ ω = 100,000 ÷ 157.1 = 637 N·m.
Q9. A synchronous motor delivers 50 kW at 1,000 rpm. What is its shaft torque approximately?
- (a) 318 N·m
- (b) 477 N·m
- (c) 637 N·m
- (d) 159 N·m
Answer: (b) 477 N·m — ω = 2π × 1,000 ÷ 60 = 104.7 rad/s, so T = P ÷ ω = 50,000 ÷ 104.7 = 477 N·m.
Q10. Which of these increases the pull-out torque of a synchronous motor?
- (a) Reducing the excitation
- (b) Increasing the excitation
- (c) Reducing the supply voltage
- (d) Increasing the load angle beyond 90 degrees
Answer: (b) Increasing the excitation — a stronger rotor field raises the maximum torque the motor can develop before pull-out.
Also read: Separately Excited DC Motor | All MCQ Topics