Single-Phase Motor MCQs — Set 3
10 practice questions on capacitor-run (permanent split capacitor) motors — how they run, why they are quiet and where they are used — with answers and explanations.
Q1. How does a capacitor-run (PSC) motor differ from a capacitor-start motor?
- (a) The PSC motor has no centrifugal switch and its capacitor stays in circuit while running
- (b) The PSC motor has no capacitor at all
- (c) The PSC motor has two centrifugal switches
- (d) The PSC motor cannot run on AC supply
Answer: (a) The PSC motor has no centrifugal switch and its capacitor stays in circuit while running — the run capacitor is an oil-filled type rated for continuous duty.
Q2. Which of these is a classic application of a permanent split capacitor (PSC) motor?
- (a) A ceiling fan
- (b) A large air compressor
- (c) A rolling-mill drive
- (d) An electric locomotive
Answer: (a) A ceiling fan — PSC motors are quiet, smooth-running and reliable, which suits fans, blowers and small pumps.
Q3. What type of capacitor is used as the run capacitor in a PSC motor?
- (a) An electrolytic capacitor rated for short duty only
- (b) An oil-filled (paper or film) capacitor rated for continuous duty
- (c) A ceramic disc capacitor
- (d) A variable air capacitor
Answer: (b) An oil-filled (paper or film) capacitor rated for continuous duty — unlike a starting capacitor, it must survive being energised the whole time the motor runs.
Q4. Compared with a capacitor-start motor, the starting torque of a PSC motor is usually what?
- (a) Higher
- (b) Lower
- (c) Exactly the same
- (d) Infinite
Answer: (b) Lower — the small run capacitor gives only a modest phase split at start, so a PSC motor suits loads that need little starting torque, such as fans.
Q5. What effect does the run capacitor have on a PSC motor while it is running?
- (a) It improves the power factor and makes running smoother and quieter
- (b) It doubles the supply voltage
- (c) It stops the rotor from turning
- (d) It increases the slip to 50%
Answer: (a) It improves the power factor and makes running smoother and quieter — the capacitor keeps the auxiliary winding active, giving a more balanced two-phase-like field.
Q6. A 2-pole PSC fan motor runs at 2,850 rpm on a 50 Hz supply. What is its percentage slip?
- (a) 2%
- (b) 5%
- (c) 10%
- (d) 15%
Answer: (b) 5% — synchronous speed is 3,000 rpm, so slip = (3,000 − 2,850) ÷ 3,000 × 100 = 5%.
Q7. If the run capacitor of a ceiling-fan PSC motor fails open, what symptom is most likely?
- (a) The fan runs at double speed
- (b) The fan hums, starts slowly or needs a push, and runs slower than normal
- (c) The fan trips the RCCB instantly
- (d) The fan reverses every minute
Answer: (b) The fan hums, starts slowly or needs a push, and runs slower than normal — with no capacitor the auxiliary winding gives almost no phase split, so starting torque nearly vanishes.
Q8. In a PSC motor, which winding stays connected to the supply for the whole time the motor runs?
- (a) Only the main winding
- (b) Both the main winding and the auxiliary winding (through the capacitor)
- (c) Only the auxiliary winding
- (d) Neither — both are switched off after starting
Answer: (b) Both the main winding and the auxiliary winding (through the capacitor) — that is why it is called a permanent split capacitor motor.
Q9. How is the speed of a ceiling-fan PSC motor usually controlled?
- (a) By changing the number of poles with a switch
- (b) By a series regulator (resistance or electronic) that reduces the voltage to the motor
- (c) By changing the supply frequency to 100 Hz
- (d) By swapping the capacitor for a larger one each time
Answer: (b) By a series regulator (resistance or electronic) that reduces the voltage to the motor — lowering the voltage reduces the torque and the fan settles at a lower speed.
Q10. What supply frequency corresponds to a 6-pole motor with a synchronous speed of 1,000 rpm?
- (a) 25 Hz
- (b) 50 Hz
- (c) 60 Hz
- (d) 100 Hz
Answer: (b) 50 Hz — f = P × Ns ÷ 120 = 6 × 1,000 ÷ 120 = 50 Hz.
Also read: Tower Fans Guide | All MCQ Topics