Q1. How does a capacitor-run (PSC) motor differ from a capacitor-start motor?

  • (a) The PSC motor has no centrifugal switch and its capacitor stays in circuit while running
  • (b) The PSC motor has no capacitor at all
  • (c) The PSC motor has two centrifugal switches
  • (d) The PSC motor cannot run on AC supply

Answer: (a) The PSC motor has no centrifugal switch and its capacitor stays in circuit while running — the run capacitor is an oil-filled type rated for continuous duty.

Q2. Which of these is a classic application of a permanent split capacitor (PSC) motor?

  • (a) A ceiling fan
  • (b) A large air compressor
  • (c) A rolling-mill drive
  • (d) An electric locomotive

Answer: (a) A ceiling fan — PSC motors are quiet, smooth-running and reliable, which suits fans, blowers and small pumps.

Q3. What type of capacitor is used as the run capacitor in a PSC motor?

  • (a) An electrolytic capacitor rated for short duty only
  • (b) An oil-filled (paper or film) capacitor rated for continuous duty
  • (c) A ceramic disc capacitor
  • (d) A variable air capacitor

Answer: (b) An oil-filled (paper or film) capacitor rated for continuous duty — unlike a starting capacitor, it must survive being energised the whole time the motor runs.

Q4. Compared with a capacitor-start motor, the starting torque of a PSC motor is usually what?

  • (a) Higher
  • (b) Lower
  • (c) Exactly the same
  • (d) Infinite

Answer: (b) Lower — the small run capacitor gives only a modest phase split at start, so a PSC motor suits loads that need little starting torque, such as fans.

Q5. What effect does the run capacitor have on a PSC motor while it is running?

  • (a) It improves the power factor and makes running smoother and quieter
  • (b) It doubles the supply voltage
  • (c) It stops the rotor from turning
  • (d) It increases the slip to 50%

Answer: (a) It improves the power factor and makes running smoother and quieter — the capacitor keeps the auxiliary winding active, giving a more balanced two-phase-like field.

Q6. A 2-pole PSC fan motor runs at 2,850 rpm on a 50 Hz supply. What is its percentage slip?

  • (a) 2%
  • (b) 5%
  • (c) 10%
  • (d) 15%

Answer: (b) 5% — synchronous speed is 3,000 rpm, so slip = (3,000 − 2,850) ÷ 3,000 × 100 = 5%.

Q7. If the run capacitor of a ceiling-fan PSC motor fails open, what symptom is most likely?

  • (a) The fan runs at double speed
  • (b) The fan hums, starts slowly or needs a push, and runs slower than normal
  • (c) The fan trips the RCCB instantly
  • (d) The fan reverses every minute

Answer: (b) The fan hums, starts slowly or needs a push, and runs slower than normal — with no capacitor the auxiliary winding gives almost no phase split, so starting torque nearly vanishes.

Q8. In a PSC motor, which winding stays connected to the supply for the whole time the motor runs?

  • (a) Only the main winding
  • (b) Both the main winding and the auxiliary winding (through the capacitor)
  • (c) Only the auxiliary winding
  • (d) Neither — both are switched off after starting

Answer: (b) Both the main winding and the auxiliary winding (through the capacitor) — that is why it is called a permanent split capacitor motor.

Q9. How is the speed of a ceiling-fan PSC motor usually controlled?

  • (a) By changing the number of poles with a switch
  • (b) By a series regulator (resistance or electronic) that reduces the voltage to the motor
  • (c) By changing the supply frequency to 100 Hz
  • (d) By swapping the capacitor for a larger one each time

Answer: (b) By a series regulator (resistance or electronic) that reduces the voltage to the motor — lowering the voltage reduces the torque and the fan settles at a lower speed.

Q10. What supply frequency corresponds to a 6-pole motor with a synchronous speed of 1,000 rpm?

  • (a) 25 Hz
  • (b) 50 Hz
  • (c) 60 Hz
  • (d) 100 Hz

Answer: (b) 50 Hz — f = P × Ns ÷ 120 = 6 × 1,000 ÷ 120 = 50 Hz.