Relay MCQs — Set 8

10 practice questions on solid-state relays — optocoupler isolation, zero-crossing switching, heatsinks and where SSRs beat mechanical relays.

Q1. What is a solid-state relay (SSR)?

  • (a) A relay with very heavy steel contacts
  • (b) An electronic switching device with no moving parts that switches a load using semiconductors
  • (c) A relay filled with solid oil
  • (d) A relay that only works when frozen

Answer: (b) An electronic switching device with no moving parts that switches a load using semiconductors — a triac or transistor does the switching instead of contacts.

Q2. What provides the electrical isolation between the control side and the load side in an SSR?

  • (a) A bimetallic strip
  • (b) An optocoupler (opto-isolator)
  • (c) A fuse
  • (d) A cooling fan

Answer: (b) An optocoupler (opto-isolator) — an LED and a light-sensitive device transfer the signal with light, so there is no electrical connection between the two sides.

Q3. What is the main advantage of a solid-state relay over an electromagnetic relay?

  • (a) It is always cheaper
  • (b) It switches much faster, has no contacts to wear out or arc, and works silently
  • (c) It can switch higher voltages than any contactor
  • (d) It needs no control signal at all

Answer: (b) It switches much faster, has no contacts to wear out or arc, and works silently — there is nothing mechanical to bounce, wear or make noise.

Q4. What is a disadvantage of a solid-state relay compared with a mechanical relay?

  • (a) It switches too fast to use
  • (b) It has a voltage drop across its output, produces heat, and leaks a small current even when off
  • (c) It cannot be mounted on a panel
  • (d) It only works on DC

Answer: (b) It has a voltage drop across its output, produces heat, and leaks a small current even when off — the semiconductor is never a perfect open or closed switch.

Q5. What is zero-crossing switching in a solid-state relay?

  • (a) Switching the load only when the AC voltage passes through zero
  • (b) Switching the load at the peak of the AC voltage
  • (c) Switching both the live and neutral at different times
  • (d) Switching the relay off at random

Answer: (a) Switching the load only when the AC voltage passes through zero — this reduces inrush current, electrical noise and interference.

Q6. Which type of load is a solid-state relay best suited to switch?

  • (a) A motor that starts once a year
  • (b) A resistive heater that is switched on and off frequently
  • (c) A load that must be fully isolated with zero leakage when off
  • (d) A load larger than the SSR rating

Answer: (b) A resistive heater that is switched on and off frequently — SSRs handle many switching cycles without contact wear, and heaters suit zero-crossing switching.

Q7. Why does a solid-state relay usually need a heatsink?

  • (a) To keep the optocoupler cool in winter
  • (b) To carry away the heat produced by the voltage drop across the output semiconductor when load current flows
  • (c) To increase the switching speed
  • (d) To protect the relay from lightning

Answer: (b) To carry away the heat produced by the voltage drop across the output semiconductor when load current flows — power loss is voltage drop × load current.

Q8. An SSR has an output voltage drop of 1.5 V while carrying 10 A. How much power does it dissipate as heat?

  • (a) 1.5 W
  • (b) 6.7 W
  • (c) 15 W
  • (d) 150 W

Answer: (c) 15 W — power = voltage × current = 1.5 × 10 = 15 W, which is why a heatsink is needed.

Q9. Can an AC-output solid-state relay (triac type) switch a DC load?

  • (a) Yes, it works the same on DC
  • (b) No, a triac cannot turn off on DC because the current never crosses zero
  • (c) Yes, but only below 5 V
  • (d) No, because DC damages the optocoupler

Answer: (b) No, a triac cannot turn off on DC because the current never crosses zero — a DC load needs an SSR with a DC output device such as a MOSFET or transistor.

Q10. How does the switching speed of a solid-state relay compare with that of an electromagnetic relay?

  • (a) The SSR is much faster, switching in under a millisecond, while a mechanical relay takes several milliseconds
  • (b) The SSR is much slower
  • (c) Both switch at exactly the same speed
  • (d) The SSR takes about one second to switch

Answer: (a) The SSR is much faster, switching in under a millisecond, while a mechanical relay takes several milliseconds — the SSR has no armature to move.

Also read: Breaker Watts Calculator | All MCQ Topics