Relay MCQs — Set 8
10 practice questions on solid-state relays — optocoupler isolation, zero-crossing switching, heatsinks and where SSRs beat mechanical relays.
Q1. What is a solid-state relay (SSR)?
- (a) A relay with very heavy steel contacts
- (b) An electronic switching device with no moving parts that switches a load using semiconductors
- (c) A relay filled with solid oil
- (d) A relay that only works when frozen
Answer: (b) An electronic switching device with no moving parts that switches a load using semiconductors — a triac or transistor does the switching instead of contacts.
Q2. What provides the electrical isolation between the control side and the load side in an SSR?
- (a) A bimetallic strip
- (b) An optocoupler (opto-isolator)
- (c) A fuse
- (d) A cooling fan
Answer: (b) An optocoupler (opto-isolator) — an LED and a light-sensitive device transfer the signal with light, so there is no electrical connection between the two sides.
Q3. What is the main advantage of a solid-state relay over an electromagnetic relay?
- (a) It is always cheaper
- (b) It switches much faster, has no contacts to wear out or arc, and works silently
- (c) It can switch higher voltages than any contactor
- (d) It needs no control signal at all
Answer: (b) It switches much faster, has no contacts to wear out or arc, and works silently — there is nothing mechanical to bounce, wear or make noise.
Q4. What is a disadvantage of a solid-state relay compared with a mechanical relay?
- (a) It switches too fast to use
- (b) It has a voltage drop across its output, produces heat, and leaks a small current even when off
- (c) It cannot be mounted on a panel
- (d) It only works on DC
Answer: (b) It has a voltage drop across its output, produces heat, and leaks a small current even when off — the semiconductor is never a perfect open or closed switch.
Q5. What is zero-crossing switching in a solid-state relay?
- (a) Switching the load only when the AC voltage passes through zero
- (b) Switching the load at the peak of the AC voltage
- (c) Switching both the live and neutral at different times
- (d) Switching the relay off at random
Answer: (a) Switching the load only when the AC voltage passes through zero — this reduces inrush current, electrical noise and interference.
Q6. Which type of load is a solid-state relay best suited to switch?
- (a) A motor that starts once a year
- (b) A resistive heater that is switched on and off frequently
- (c) A load that must be fully isolated with zero leakage when off
- (d) A load larger than the SSR rating
Answer: (b) A resistive heater that is switched on and off frequently — SSRs handle many switching cycles without contact wear, and heaters suit zero-crossing switching.
Q7. Why does a solid-state relay usually need a heatsink?
- (a) To keep the optocoupler cool in winter
- (b) To carry away the heat produced by the voltage drop across the output semiconductor when load current flows
- (c) To increase the switching speed
- (d) To protect the relay from lightning
Answer: (b) To carry away the heat produced by the voltage drop across the output semiconductor when load current flows — power loss is voltage drop × load current.
Q8. An SSR has an output voltage drop of 1.5 V while carrying 10 A. How much power does it dissipate as heat?
- (a) 1.5 W
- (b) 6.7 W
- (c) 15 W
- (d) 150 W
Answer: (c) 15 W — power = voltage × current = 1.5 × 10 = 15 W, which is why a heatsink is needed.
Q9. Can an AC-output solid-state relay (triac type) switch a DC load?
- (a) Yes, it works the same on DC
- (b) No, a triac cannot turn off on DC because the current never crosses zero
- (c) Yes, but only below 5 V
- (d) No, because DC damages the optocoupler
Answer: (b) No, a triac cannot turn off on DC because the current never crosses zero — a DC load needs an SSR with a DC output device such as a MOSFET or transistor.
Q10. How does the switching speed of a solid-state relay compare with that of an electromagnetic relay?
- (a) The SSR is much faster, switching in under a millisecond, while a mechanical relay takes several milliseconds
- (b) The SSR is much slower
- (c) Both switch at exactly the same speed
- (d) The SSR takes about one second to switch
Answer: (a) The SSR is much faster, switching in under a millisecond, while a mechanical relay takes several milliseconds — the SSR has no armature to move.
Also read: Breaker Watts Calculator | All MCQ Topics