PLC Basics MCQs — Set 6
10 practice questions on PLC counters — CTU, CTD and up/down counters, presets and resets — with answers and explanations.
Q1. What does a CTU (count up) counter do?
- (a) It counts down from the preset to zero
- (b) It adds 1 to its accumulated value on each false-to-true pulse, and sets its done bit when the count reaches the preset
- (c) It delays the output by the preset time
- (d) It measures the scan time
Answer: (b) It adds 1 to its accumulated value on each false-to-true pulse, and sets its done bit when the count reaches the preset.
Q2. A CTU counter has a preset of 5. A sensor sends 5 pulses. What happens?
- (a) Nothing changes
- (b) The done bit turns on after the 5th pulse
- (c) The counter resets to zero
- (d) The output turns off
Answer: (b) The done bit turns on after the 5th pulse — accumulated value 5 equals the preset, so the DN bit is set.
Q3. A CTU counter has a preset of 10 and is counting bottles on a conveyor. After how many bottles does the done bit turn on?
- (a) 5 bottles
- (b) 9 bottles
- (c) 10 bottles
- (d) 11 bottles
Answer: (c) 10 bottles — the done bit sets when the accumulated count reaches the preset of 10.
Q4. What does a CTD (count down) counter do?
- (a) It counts up from zero to the preset
- (b) It starts at the preset value, subtracts 1 on each pulse, and sets its done bit when the count reaches zero
- (c) It delays the output by the preset time
- (d) It resets the timer
Answer: (b) It starts at the preset value, subtracts 1 on each pulse, and sets its done bit when the count reaches zero.
Q5. A CTD counter has a preset of 8. How many pulses are needed for its done bit to turn on?
- (a) 4 pulses
- (b) 7 pulses
- (c) 8 pulses
- (d) 16 pulses
Answer: (c) 8 pulses — the counter counts down from 8 to 0 in 8 pulses, and the done bit sets at zero.
Q6. How is a CTU counter reset to zero?
- (a) By turning the PLC off
- (b) By a RES (reset) instruction, or a reset input, which clears the accumulated value to zero
- (c) By pressing the start button
- (d) It resets itself after every pulse
Answer: (b) By a RES (reset) instruction, or a reset input, which clears the accumulated value to zero — the done bit also turns off when the counter is reset.
Q7. A packing machine must put 12 bottles in each case. Which counter setup does the job?
- (a) TON with a 12 s preset
- (b) CTU with a preset of 12, reset after each full case
- (c) TOF with a 12 s preset
- (d) CTD with a preset of 1
Answer: (b) CTU with a preset of 12, reset after each full case — the done bit signals a full case of 12 bottles, then the counter resets for the next case.
Q8. A CTU counter has a preset of 24 and counts parts into a box. After 24 parts, what should the program do?
- (a) Nothing — the counter keeps counting forever
- (b) Use the done bit to move the full box away and reset the counter for the next box
- (c) Switch the PLC off
- (d) Change the preset to 48
Answer: (b) Use the done bit to move the full box away and reset the counter for the next box — the done bit at 24 parts triggers the box-change sequence.
Q9. When does a counter register a count?
- (a) While its input stays ON continuously
- (b) Only on the false-to-true (rising edge) transition of its input
- (c) Once per scan, regardless of the input
- (d) Only when its reset input is ON
Answer: (b) Only on the false-to-true (rising edge) transition of its input — a steady ON input counts once, not continuously.
Q10. What is a CTUD (up/down) counter used for?
- (a) Delaying an output by the preset time
- (b) Counting in both directions, for example tracking the position of a moving carriage from an encoder
- (c) Measuring the temperature of a motor
- (d) Switching the PLC between run and program mode
Answer: (b) Counting in both directions, for example tracking the position of a moving carriage from an encoder — one input counts up, the other counts down, giving a net position.