PLC Basics MCQs — Set 3

10 practice questions on ladder logic basics — rungs, power rails, NO and NC contacts, coils and AND/OR combinations — with answers and explanations.

Q1. In a ladder diagram, what are the two vertical lines on the left and right?

  • (a) The program counter
  • (b) The power rails, representing the supply voltage
  • (c) The input and output modules
  • (d) The timer and counter

Answer: (b) The power rails, representing the supply voltage — current flows from the left rail, through the rung, to the right rail when the rung is true.

Q2. What does one horizontal rung in a ladder diagram represent?

  • (a) One complete control operation or logic circuit
  • (b) The whole PLC program
  • (c) One power supply unit
  • (d) One sensor only

Answer: (a) One complete control operation or logic circuit — each rung has input conditions on the left and usually one output coil on the right.

Q3. A normally open (NO) contact, also called XIC, in a ladder rung does what?

  • (a) It stays closed all the time
  • (b) It closes (conducts) only when its input is ON or true
  • (c) It closes only when its input is OFF
  • (d) It switches the power supply off

Answer: (b) It closes (conducts) only when its input is ON or true — “examine if closed” means the rung passes power only while the input is energised.

Q4. A normally closed (NC) contact, also called XIO, in a ladder rung does what?

  • (a) It conducts when its input is OFF, and opens when the input turns ON
  • (b) It conducts only when its input is ON
  • (c) It never conducts
  • (d) It short-circuits the power rails

Answer: (a) It conducts when its input is OFF, and opens when the input turns ON — “examine if open” is true while the input is not energised.

Q5. What does an output coil (OTE) at the end of a rung do?

  • (a) It reads a sensor
  • (b) It energises the output when the rung is true, and de-energises it when the rung is false
  • (c) It counts pulses
  • (d) It delays the program by 10 seconds

Answer: (b) It energises the output when the rung is true, and de-energises it when the rung is false — the coil mirrors the logic result of its rung.

Q6. A rung has one NO contact in series with a lamp coil. When does the lamp turn on?

  • (a) When the input is OFF
  • (b) Only when the input is ON
  • (c) Always, regardless of the input
  • (d) Only when the PLC is in program mode

Answer: (b) Only when the input is ON — the NO contact must close for power to reach the coil.

Q7. Two NO contacts wired in parallel on a rung give which logic?

  • (a) AND logic — both inputs must be ON
  • (b) OR logic — either input ON energises the output
  • (c) NOT logic
  • (d) XOR logic only

Answer: (b) OR logic — either input ON energises the output — either closed contact provides a path from the left rail to the coil.

Q8. Two NO contacts wired in series on a rung give which logic?

  • (a) OR logic — either input ON is enough
  • (b) AND logic — both inputs must be ON for the output to energise
  • (c) NOT logic
  • (d) NAND logic

Answer: (b) AND logic — both inputs must be ON for the output to energise — both contacts must close to complete the path.

Q9. Why is an NC contact often used for a stop pushbutton in a ladder rung?

  • (a) So the motor runs faster
  • (b) So that pressing the button opens the contact and breaks the rung, stopping the motor — and a broken wire also stops it safely
  • (c) So the button uses less power
  • (d) So the PLC scans faster

Answer: (b) So that pressing the button opens the contact and breaks the rung, stopping the motor — and a broken wire also stops it safely — a stop circuit should fail safe.

Q10. Ladder logic was modelled on which older technology?

  • (a) Relay schematic diagrams used in hard-wired control panels
  • (b) Printed circuit board layouts
  • (c) Hydraulic circuit diagrams
  • (d) Pneumatic flow charts

Answer: (a) Relay schematic diagrams used in hard-wired control panels — ladder logic copies relay symbols so electricians can read PLC programs easily.

Also read: Logic Gates Explained | Control and Protection MCQs | All MCQ Topics