Lift MCQs — Set 3

10 practice questions on lift motors and VVVF drives — induction motors, gearless machines and smooth control — with answers and explanations.

Q1. Which type of motor is most commonly used to drive a traction lift?

  • (a) Single-phase shaded-pole motor
  • (b) Three-phase induction motor
  • (c) Universal series motor
  • (d) Stepper motor

Answer: (b) Three-phase induction motor — rugged, reliable and able to deliver the high starting torque a lift needs.

Q2. What is the synchronous speed of a 4-pole motor running on a 50 Hz supply?

  • (a) 750 rpm
  • (b) 1,000 rpm
  • (c) 1,500 rpm
  • (d) 3,000 rpm

Answer: (c) 1,500 rpm — Ns = 120 × f ÷ P = 120 × 50 ÷ 4 = 1,500 rpm.

Q3. What does a VVVF (variable voltage variable frequency) drive do for a lift?

  • (a) It switches the motor between two fixed speeds only
  • (b) It varies the voltage and frequency fed to the motor for smooth acceleration, deceleration and accurate levelling
  • (c) It converts the lift to battery power
  • (d) It opens and closes the lift doors

Answer: (b) It varies the voltage and frequency fed to the motor for smooth acceleration, deceleration and accurate levelling — the car starts and stops gently instead of jerking.

Q4. What type of motor is used in a modern gearless traction machine?

  • (a) Shaded-pole motor
  • (b) Permanent magnet synchronous motor (PMSM)
  • (c) DC shunt motor
  • (d) Single-phase capacitor motor

Answer: (b) Permanent magnet synchronous motor (PMSM) — compact and efficient, it drives the sheave directly without a gearbox.

Q5. A lift motor is rated at 10 HP. What is its power in kilowatts?

  • (a) 0.75 kW
  • (b) 3.7 kW
  • (c) 7.5 kW
  • (d) 10.0 kW

Answer: (c) 7.5 kW — 1 HP = 746 W, so 10 × 746 = 7,460 W ≈ 7.5 kW.

Q6. A lift moves a total mass of 800 kg upward at 1.5 m/s. What is the ideal lifting power?

  • (a) 5.9 kW
  • (b) 7.8 kW
  • (c) 11.8 kW
  • (d) 17.7 kW

Answer: (c) 11.8 kW — P = m × g × v = 800 × 9.81 × 1.5 = 11,772 W ≈ 11.8 kW.

Q7. What is the main drawback of the older two-speed AC (ACVV) lift drive compared with VVVF?

  • (a) It uses too little power
  • (b) It gives a jerky stop and less accurate floor levelling
  • (c) It cannot run on three-phase supply
  • (d) It needs a counterweight

Answer: (b) It gives a jerky stop and less accurate floor levelling — the motor switches abruptly between high and low speed instead of ramping smoothly.

Q8. What is the job of the encoder fitted on a lift motor?

  • (a) To open the landing doors
  • (b) To give the drive speed and position feedback so it can control the car precisely
  • (c) To weigh the passengers in the car
  • (d) To earth the motor frame

Answer: (b) To give the drive speed and position feedback so it can control the car precisely — the controller uses it for speed regulation and floor levelling.

Q9. What does a regenerative lift drive do when the car brakes?

  • (a) It wastes the braking energy as heat in resistors
  • (b) It feeds the braking energy back into the building’s electrical supply
  • (c) It charges the door operator battery only
  • (d) It stops the counterweight from moving

Answer: (b) It feeds the braking energy back into the building’s electrical supply — the motor acts as a generator during braking and returns energy instead of wasting it.

Q10. Why does a lift motor need high starting torque?

  • (a) Because the car must start smoothly from standstill even under full load
  • (b) Because the doors open at the same time
  • (c) Because the counterweight is removed at start
  • (d) Because the lift runs on single-phase supply

Answer: (a) Because the car must start smoothly from standstill even under full load — the motor must overcome the unbalanced load and static friction at zero speed.

Also read: Separately Excited DC Motor | All MCQ Topics