EV Charging MCQs — Set 2
10 practice questions on Level 1, Level 2 and DC fast charging — voltages, power levels and charging speeds.
Q1. What supply does Level 1 EV charging normally use?
- (a) 400 V three-phase
- (b) 120 V from a standard household outlet
- (c) 480 V DC
- (d) 230 V three-phase
Answer: (b) 120 V from a standard household outlet — Level 1 uses an ordinary domestic socket and is the slowest form of charging.
Q2. A Level 1 charger draws 12 A from a 120 V supply. What power does it deliver?
- (a) 1.44 kW
- (b) 2.40 kW
- (c) 3.60 kW
- (d) 0.72 kW
Answer: (a) 1.44 kW — P = V × I = 120 V × 12 A = 1,440 W = 1.44 kW.
Q3. A Level 2 charger supplies 240 V at 30 A. What is its power output?
- (a) 3.6 kW
- (b) 7.2 kW
- (c) 11 kW
- (d) 9.6 kW
Answer: (b) 7.2 kW — P = V × I = 240 V × 30 A = 7,200 W = 7.2 kW.
Q4. What is the key difference between DC fast charging and Level 1/Level 2 charging?
- (a) DC fast charging uses a smaller cable
- (b) DC fast charging bypasses the onboard charger and feeds DC directly to the battery
- (c) DC fast charging only works at home
- (d) DC fast charging charges the 12 V battery only
Answer: (b) DC fast charging bypasses the onboard charger and feeds DC directly to the battery — the large offboard charger does the AC-to-DC conversion, so much higher power is possible.
Q5. Which charging level adds the most driving range per hour?
- (a) Level 1
- (b) Level 2
- (c) DC fast charging
- (d) All levels add the same range per hour
Answer: (c) DC fast charging — at 50–350 kW it delivers far more energy per hour than Level 1 (about 1.4 kW) or Level 2 (about 7–22 kW).
Q6. A 60 kWh battery is charged on a 7.2 kW Level 2 charger. How long does a full charge take?
- (a) 5.5 hours
- (b) 8.3 hours
- (c) 10.2 hours
- (d) 6.9 hours
Answer: (b) 8.3 hours — time = 60 kWh ÷ 7.2 kW = 8.33 hours, about 8.3 hours.
Q7. A Level 1 charger delivers 1.44 kW for 10 hours overnight. How much energy is added?
- (a) 7.2 kWh
- (b) 10.0 kWh
- (c) 14.4 kWh
- (d) 21.6 kWh
Answer: (c) 14.4 kWh — energy = 1.44 kW × 10 h = 14.4 kWh.
Q8. Which charging level is normally installed as a dedicated wall box at home?
- (a) Level 1 only
- (b) Level 2
- (c) DC fast charging only
- (d) None — home charging is not possible
Answer: (b) Level 2 — a home wall box is a Level 2 AC charger on its own dedicated circuit, typically 7–22 kW.
Q9. What is the typical power range of a DC fast charger?
- (a) 1–2 kW
- (b) 3–7 kW
- (c) 50–350 kW
- (d) 500–1000 kW
Answer: (c) 50–350 kW — DC fast chargers commonly deliver 50 kW, 150 kW or up to 350 kW, far above Level 2 AC charging.
Q10. A Level 2 charger supplies 240 V at 40 A. What is its power output?
- (a) 7.2 kW
- (b) 9.6 kW
- (c) 11 kW
- (d) 6.0 kW
Answer: (b) 9.6 kW — P = V × I = 240 V × 40 A = 9,600 W = 9.6 kW.