DC Generator MCQs — Set 8
10 practice questions on voltage regulation and the characteristics of DC generators.
Q1. A DC generator has a no-load voltage of 240 V and a full-load voltage of 220 V. What is its percentage voltage regulation?
- (a) 4.5%
- (b) 9.1%
- (c) 20%
- (d) 8.3%
Answer: (b) 9.1% — regulation = (Vnl − Vfl) ÷ Vfl × 100 = (240 − 220) ÷ 220 × 100 = 20 ÷ 220 × 100 = 9.09% ≈ 9.1%.
Q2. A DC generator has a no-load voltage of 230 V and a full-load voltage of 220 V. What is its percentage voltage regulation?
- (a) 10%
- (b) 4.5%
- (c) 9.1%
- (d) 2.2%
Answer: (b) 4.5% — regulation = (230 − 220) ÷ 220 × 100 = 10 ÷ 220 × 100 = 4.55% ≈ 4.5%.
Q3. A DC generator has a no-load voltage of 220 V and a full-load voltage of 200 V. What is its percentage voltage regulation?
- (a) 5%
- (b) 9.1%
- (c) 10%
- (d) 20%
Answer: (c) 10% — regulation = (220 − 200) ÷ 200 × 100 = 20 ÷ 200 × 100 = 10%.
Q4. The open-circuit characteristic (OCC) of a DC generator is a graph of:
- (a) Terminal voltage against load current
- (b) Generated EMF against field current at constant speed
- (c) Efficiency against output power
- (d) Speed against load current
Answer: (b) Generated EMF against field current at constant speed — also called the magnetisation curve, it shows how EMF rises with field current until saturation.
Q5. The external characteristic of a DC generator is a graph of:
- (a) Generated EMF against field current
- (b) Terminal voltage against load current
- (c) Speed against field current
- (d) Power against efficiency
Answer: (b) Terminal voltage against load current — it shows how the terminal voltage behaves as the machine is loaded.
Q6. A shunt generator’s external characteristic droops (voltage falls) with increasing load mainly because of:
- (a) Increasing field current
- (b) Armature resistance drop and armature reaction
- (c) Rising prime mover speed
- (d) Decreasing brush resistance
Answer: (b) Armature resistance drop and armature reaction — both grow with load current and pull the terminal voltage down.
Q7. What is the critical field resistance of a self-excited DC generator?
- (a) The resistance at which efficiency is maximum
- (b) The maximum field-circuit resistance at which the generator can still build up voltage
- (c) The resistance of the armature winding
- (d) The resistance of the load at full load
Answer: (b) The maximum field-circuit resistance at which the generator can still build up voltage — above this resistance the field line misses the OCC and no build-up occurs.
Q8. What is the percentage voltage regulation of an ideal DC generator?
- (a) 100%
- (b) 50%
- (c) 0%
- (d) 10%
Answer: (c) 0% — an ideal generator holds exactly the same terminal voltage at no load and full load.
Q9. Which test is used to determine the voltage regulation of a DC generator?
- (a) A load test, measuring terminal voltage at no load and at full load
- (b) A short-circuit test only
- (c) An insulation resistance test
- (d) A no-load test only
Answer: (a) A load test, measuring terminal voltage at no load and at full load — regulation is calculated from those two voltages.
Q10. In the open-circuit characteristic, the curve flattens at high field currents because:
- (a) The armature resistance increases
- (b) The magnetic iron saturates
- (c) The speed falls
- (d) The commutator sparks
Answer: (b) The magnetic iron saturates — once saturated, extra field current produces very little extra flux, so EMF rises only slowly.
Also read: Separately Excited DC Motor | All MCQ Topics