Q1. In a separately excited DC generator, the field winding is supplied from:
- (a) The generator’s own armature
- (b) An external DC source
- (c) The load terminals only
- (d) A battery connected in series with the load
Answer: (b) An external DC source — the field is independent of the armature, so flux can be controlled separately.
Q2. What makes voltage build-up possible in a self-excited DC generator?
- (a) A permanent magnet rotor
- (b) Residual magnetism in the field poles
- (c) An external battery
- (d) The commutator
Answer: (b) Residual magnetism in the field poles — the small residual flux induces a small EMF, which drives field current that strengthens the flux until voltage builds up.
Q3. A shunt field winding has a resistance of 46 Ω and is connected across a 230 V supply. What is the shunt field current?
- (a) 2 A
- (b) 5 A
- (c) 10 A
- (d) 0.2 A
Answer: (b) 5 A — Ish = V ÷ Rsh = 230 ÷ 46 = 5 A.
Q4. A self-excited shunt generator fails to build up voltage. Which of these is a likely cause?
- (a) The load is too small
- (b) There is no residual magnetism left in the poles
- (c) The speed is too high
- (d) The field resistance is too low
Answer: (b) There is no residual magnetism left in the poles — without residual flux there is no initial EMF to start the build-up process.
Q5. In a series DC generator, the field winding is connected:
- (a) Across the armature
- (b) In series with the armature
- (c) Across the load only
- (d) To an external DC source
Answer: (b) In series with the armature — the field carries the full load current, so its flux varies with load.
Q6. A compound DC generator has how many field windings?
- (a) One shunt winding only
- (b) One series winding only
- (c) Both a shunt winding and a series winding
- (d) No field winding at all
Answer: (c) Both a shunt winding and a series winding — the combination gives the steady voltage of a shunt machine with the load-boost of a series machine.
Q7. During voltage build-up in a self-excited generator, what happens after the residual flux induces a small EMF?
- (a) The EMF falls to zero
- (b) A small field current flows, increasing the flux, which increases the EMF further
- (c) The commutator reverses the field connections
- (d) The armature current stops flowing
Answer: (b) A small field current flows, increasing the flux, which increases the EMF further — this cumulative process continues until saturation limits the voltage.
Q8. What is the main advantage of a separately excited DC generator over a self-excited one?
- (a) It needs no prime mover
- (b) Its field flux can be controlled independently of load and armature voltage
- (c) It has no commutator
- (d) It produces AC output
Answer: (b) Its field flux can be controlled independently of load and armature voltage — useful for precise voltage control and testing.
Q9. What is the critical speed of a self-excited DC generator?
- (a) The maximum safe running speed
- (b) The speed below which the generator fails to build up voltage
- (c) The speed at which efficiency is highest
- (d) The synchronous speed of the prime mover
Answer: (b) The speed below which the generator fails to build up voltage — at low speed the induced EMF cannot drive enough field current to sustain build-up.
Q10. The shunt field winding of a DC generator is made of:
- (a) A few turns of thick wire
- (b) Many turns of thin wire
- (c) A single turn of copper bar
- (d) Laminated iron strips
Answer: (b) Many turns of thin wire — it carries only a small current but must produce enough ampere-turns, so it has high resistance and many turns.