Compressor MCQs — Set 3
10 practice questions on air receiver tanks and compressed-air treatment, with answers and explanations.
Q1. What is the main purpose of an air receiver tank?
- (a) To cool the motor
- (b) To store compressed air, smooth out pulsations and meet short peak demands
- (c) To filter oil out of the air
- (d) To increase the compressor speed
Answer: (b) To store compressed air, smooth out pulsations and meet short peak demands — the tank acts as a buffer between the pump and the tools.
Q2. A 100-litre receiver is charged to 8 bar. Approximately how much free air does it hold?
- (a) 100 litres
- (b) 400 litres
- (c) 800 litres
- (d) 8,000 litres
Answer: (c) 800 litres — free air ≈ tank volume × pressure = 100 × 8 = 800 litres.
Q3. A 200-litre receiver is charged to 7 bar. Approximately how much free air does it hold?
- (a) 700 litres
- (b) 1,400 litres
- (c) 2,800 litres
- (d) 200 litres
Answer: (b) 1,400 litres — free air ≈ tank volume × pressure = 200 × 7 = 1,400 litres.
Q4. Why should a receiver tank be drained of condensate every day?
- (a) To save electricity
- (b) Because collected water causes rust and corrosion inside the tank
- (c) To increase the cut-out pressure
- (d) To lubricate the pump
Answer: (b) Because collected water causes rust and corrosion inside the tank — water condenses out of compressed air as it cools in the receiver.
Q5. What does an aftercooler do in a compressed-air system?
- (a) It heats the air before use
- (b) It cools the hot discharge air so moisture condenses out before the air reaches the receiver
- (c) It raises the air pressure
- (d) It adds oil to the air
Answer: (b) It cools the hot discharge air so moisture condenses out before the air reaches the receiver — hot air from the pump holds water vapour that must be removed.
Q6. What is the job of an air dryer?
- (a) To remove moisture from compressed air so tools and pipework stay dry
- (b) To heat the receiver tank
- (c) To increase CFM
- (d) To drain oil from the pump
Answer: (a) To remove moisture from compressed air so tools and pipework stay dry — wet air rusts tools and ruins paint finishes.
Q7. In a filter–regulator–lubricator (FRL) unit, what is the correct order of the air flow?
- (a) Lubricator, filter, regulator
- (b) Regulator, lubricator, filter
- (c) Filter, regulator, lubricator
- (d) Filter, lubricator, regulator
Answer: (c) Filter, regulator, lubricator — air is first cleaned, then set to the working pressure, then oiled for the tool.
Q8. Why is a non-return (check) valve fitted between the pump and the receiver?
- (a) To stop receiver air flowing back into the pump when the compressor stops
- (b) To drain water from the receiver
- (c) To cool the discharge air
- (d) To filter the intake air
Answer: (a) To stop receiver air flowing back into the pump when the compressor stops — without it, stored air would escape back through the pump.
Q9. Where is the safety (relief) valve fitted, and how is it set?
- (a) On the receiver, set above the maximum working pressure
- (b) On the motor, set to the full-load current
- (c) On the intake filter, set to atmospheric pressure
- (d) On the drain valve, set to zero
Answer: (a) On the receiver, set above the maximum working pressure — it opens to vent air if the pressure ever rises dangerously high.
Q10. What happens if a receiver is never drained?
- (a) Nothing — water never collects in a receiver
- (b) Water builds up, reduces the air storage, rusts the tank and reaches the tools
- (c) The pressure rises above the safety valve setting
- (d) The motor runs faster
Answer: (b) Water builds up, reduces the air storage, rusts the tank and reaches the tools — regular draining is the simplest receiver maintenance.
Also read: Power Loss Formula | All MCQ Topics