Charge Controller MCQs — Set 4
10 practice questions on sizing a charge controller — the Isc × 1.25 rule, series and parallel arrays, and watt limits. Work each one out before checking the answer.
Q1. A solar array has a total short-circuit current (Isc) of 16 A. What size charge controller should be used?
- (a) 16 A
- (b) 20 A
- (c) 30 A
- (d) 60 A
Answer: (c) 30 A — controller current = Isc × 1.25 = 16 × 1.25 = 20 A, so the next standard size up is a 30 A controller.
Q2. A solar array has a total short-circuit current (Isc) of 8 A. What size charge controller should be used?
- (a) 8 A
- (b) 10 A
- (c) 20 A
- (d) 5 A
Answer: (c) 20 A — controller current = Isc × 1.25 = 8 × 1.25 = 10 A, so the next standard size up is a 20 A controller.
Q3. Two solar panels, each with Isc = 9 A, are wired in parallel. What controller size is needed?
- (a) 10 A
- (b) 20 A
- (c) 30 A
- (d) 40 A
Answer: (c) 30 A — in parallel the currents add: total Isc = 9 + 9 = 18 A; 18 × 1.25 = 22.5 A, so the next standard size up is a 30 A controller.
Q4. Three solar panels, each with Isc = 9 A, are wired in series. What controller size is needed?
- (a) 20 A
- (b) 30 A
- (c) 40 A
- (d) 60 A
Answer: (a) 20 A — in series the current stays the same: total Isc = 9 A; 9 × 1.25 = 11.25 A, so a 20 A controller is enough (series adds voltage, not current).
Q5. What is the maximum solar array wattage a 30 A charge controller can handle on a 12 V system?
- (a) 720 W
- (b) 360 W
- (c) 240 W
- (d) 1,440 W
Answer: (b) 360 W — P = V × I = 12 × 30 = 360 W.
Q6. The same 30 A charge controller is used on a 24 V system instead of 12 V. What is its maximum array wattage now?
- (a) 360 W
- (b) 720 W
- (c) 180 W
- (d) 30 W
Answer: (b) 720 W — P = V × I = 24 × 30 = 720 W; doubling the system voltage doubles the watts a given current rating can handle.
Q7. Why must the array’s open-circuit voltage (Voc) never exceed the controller’s maximum PV input voltage?
- (a) The battery would charge too slowly
- (b) Excess voltage can damage or destroy the controller
- (c) The panels would produce no current
- (d) The load terminals would switch off
Answer: (b) Excess voltage can damage or destroy the controller — the Voc limit is a hard rating, and cold weather raises Voc further, so it must be checked with a safety margin.
Q8. A solar array has a total short-circuit current (Isc) of 12 A. What size charge controller should be used?
- (a) 12 A
- (b) 15 A
- (c) 20 A
- (d) 40 A
Answer: (c) 20 A — controller current = Isc × 1.25 = 12 × 1.25 = 15 A, so the next standard size up is a 20 A controller.
Q9. A solar array has a total short-circuit current (Isc) of 20 A. What size charge controller should be used?
- (a) 20 A
- (b) 25 A
- (c) 30 A
- (d) 50 A
Answer: (c) 30 A — controller current = Isc × 1.25 = 20 × 1.25 = 25 A, so the next standard size up is a 30 A controller.
Q10. A solar array rated well above the controller’s wattage limit is connected to it. What normally happens?
- (a) The controller harvests all the extra power
- (b) The controller limits (clips) its output and the extra power is wasted
- (c) The battery voltage doubles
- (d) The panels shut down completely
Answer: (b) The controller limits (clips) its output and the extra power is wasted — an oversized array on a small controller wastes money and can overheat the controller.
Also read: Cable Sizing MCQs | All MCQ Topics