Welding MCQs — Set 9
10 practice questions on welding earthing, electric shock protection, damp conditions and fire safety.
Q1. Where is the earth (return) clamp connected in arc welding?
- (a) To the electrode holder
- (b) To the workpiece or the welding table
- (c) To the shielding gas cylinder
- (d) To the welder’s helmet
Answer: (b) To the workpiece or the welding table — the clamp completes the welding circuit, giving the current a return path from the workpiece back to the machine.
Q2. Why must the workpiece be earthed in welding?
- (a) To make the arc brighter
- (b) To provide the return path for the welding current and reduce the shock risk
- (c) To hold the workpiece still
- (d) To supply the shielding gas
Answer: (b) To provide the return path for the welding current and reduce the shock risk — without a proper return path the arc is unstable, and fault current has no safe route to earth.
Q3. What happens if the earth clamp makes a poor connection to the workpiece?
- (a) The arc becomes unstable and the clamp can overheat
- (b) The welding current doubles
- (c) The shielding gas flow increases
- (d) Nothing — a loose clamp makes no difference
Answer: (a) The arc becomes unstable and the clamp can overheat — a loose or rusty clamp has high resistance, so the arc sputters and the clamp itself can get hot enough to burn.
Q4. Why must welding never be done in rain or on a wet surface?
- (a) The rain cools the weld too fast
- (b) Wet conditions greatly increase the risk of electric shock
- (c) The electrode will not melt in rain
- (d) The helmet fogs up
Answer: (b) Wet conditions greatly increase the risk of electric shock — water lowers the body’s resistance and provides a path for current, so welding in damp conditions can be fatal.
Q5. Which RCCB (residual current device) rating is used for protection against electric shock?
- (a) 500 mA
- (b) 100 mA
- (c) 30 mA
- (d) 10 A
Answer: (c) 30 mA — a 30 mA RCCB trips fast enough on a small leakage current to protect a person from a serious shock.
Q6. What reduces the shock risk when welding must be done in damp conditions?
- (a) Wearing wet gloves
- (b) Dry insulating gloves, dry clothing and standing on an insulated mat
- (c) Removing the earth clamp
- (d) Increasing the welding current
Answer: (b) Dry insulating gloves, dry clothing and standing on an insulated mat — dry insulation breaks the path for leakage current through the body, which is the main danger in damp work.
Q7. Why is the metal body of a welding machine earthed?
- (a) To make the machine heavier
- (b) So a fault inside the machine sends current safely to earth instead of through the welder
- (c) To increase the welding current
- (d) To reduce the open-circuit voltage
Answer: (b) So a fault inside the machine sends current safely to earth instead of through the welder — if a live wire touches the case, the earth path trips the protection instead of leaving the case live.
Q8. What must be checked on welding cables before starting work?
- (a) That they are the correct colour
- (b) That the insulation is not damaged and no bare conductor is exposed
- (c) That they are as long as possible
- (d) That they are coiled tightly
Answer: (b) That the insulation is not damaged and no bare conductor is exposed — damaged cables can shock the welder, short out, or start a fire, so they must be repaired or replaced before use.
Q9. A 20 A, 120 V circuit should not be loaded beyond 80% of its rating. What is the maximum safe load?
- (a) 1,200 W
- (b) 1,920 W
- (c) 2,400 W
- (d) 2,000 W
Answer: (b) 1,920 W — the full rating is 20 × 120 = 2,400 W, and 80% of that is 0.80 × 2,400 = 1,920 W.
Q10. What must be done before welding near flammable material?
- (a) Nothing — sparks cannot start a fire
- (b) Remove the flammable material or shield it, and keep a fire watch with an extinguisher nearby
- (c) Wet the electrode
- (d) Weld as fast as possible
Answer: (b) Remove the flammable material or shield it, and keep a fire watch with an extinguisher nearby — welding sparks and hot slag can smoulder for hours, so the area must be cleared and watched after welding stops.
Also read: AFCI Breaker Keeps Tripping | All MCQ Topics