Electrical Troubleshooting MCQs — Set 10

10 practice questions on when to escalate a fault, safe working limits and recording what you found, with answers explained.

Q1. You find a burnt smell and scorch marks inside a distribution board. What is the correct action?

  • (a) Switch it back on and see if it works
  • (b) Isolate the board, do not re-energise it, and escalate to a qualified electrician — heat damage is a fire risk
  • (c) Spray it with water
  • (d) Fit a larger breaker

Answer: (b) Isolate the board, do not re-energise it, and escalate to a qualified electrician — heat damage is a fire risk — scorching means a connection has already overheated, and the cause must be found before power returns.

Q2. When should a fault be escalated to a qualified electrician rather than fixed by the homeowner?

  • (a) When a lamp needs replacing
  • (b) When the work involves the distribution board, the meter, or any fault you cannot positively identify and prove safe
  • (c) When the fault is in a plug
  • (d) Never — every fault can be fixed by anyone

Answer: (b) When the work involves the distribution board, the meter, or any fault you cannot positively identify and prove safe — live parts, unknown faults and protective devices are beyond safe DIY work.

Q3. Why should you never work on a circuit that you have only switched off at the wall switch?

  • (a) The switch might be decorative
  • (b) The switch may be wired in the neutral, leaving the circuit live even when off — isolate at the breaker or fuse and prove dead
  • (c) The breaker will trip
  • (d) The lamp will still glow

Answer: (b) The switch may be wired in the neutral, leaving the circuit live even when off — isolate at the breaker or fuse and prove dead — only isolation at the protective device plus a dead test makes the circuit safe to touch.

Q4. A fault keeps returning after three repairs by different people. What is the best next step?

  • (a) Repair it the same way a fourth time
  • (b) Stop repeating the same fix — record the full history, re-diagnose from the start, and escalate for a second opinion
  • (c) Fit a bigger fuse so it stops failing
  • (d) Ignore it

Answer: (b) Stop repeating the same fix — record the full history, re-diagnose from the start, and escalate for a second opinion — a recurring fault means the real cause has never been found; the history is the clue.

Q5. What should a fault record include after a repair is finished?

  • (a) Only the date
  • (b) The symptoms, the tests done and their readings, the fault found, the repair made, and the final test results
  • (c) The customer’s phone number only
  • (d) Nothing — records are a waste of time

Answer: (b) The symptoms, the tests done and their readings, the fault found, the repair made, and the final test results — a complete record proves the repair and makes the next fault on that circuit far quicker to find.

Q6. You are troubleshooting and discover aluminium wiring joined directly to copper wiring with no approved connector. What do you do?

  • (a) Leave it — it works fine
  • (b) Flag it as a serious fault and escalate — dissimilar metals corrode at the joint, causing heat and fire risk
  • (c) Tape over the joint
  • (d) Paint the joint

Answer: (b) Flag it as a serious fault and escalate — dissimilar metals corrode at the joint, causing heat and fire risk — aluminium-to-copper joints need approved connectors and compound; a plain twist joint is dangerous.

Q7. A conduit is already at the 40% fill limit. You need to add another cable while fault-finding. What is correct?

  • (a) Force the extra cable in — the limit is only a guideline
  • (b) Do not add it — the 40% fill limit exists so cables can dissipate heat and be pulled safely; run a new route instead
  • (c) Remove the earth wire to make room
  • (d) Use a thinner fuse

Answer: (b) Do not add it — the 40% fill limit exists so cables can dissipate heat and be pulled safely; run a new route instead — overfilled conduit overheats cables and damages insulation when pulled.

Q8. During troubleshooting you receive a small electric shock from an appliance casing. What is the correct response?

  • (a) Carry on — small shocks are normal
  • (b) Stop work, isolate the appliance and the circuit, and treat it as an earth fault — a live casing means protective earthing has failed
  • (c) Wear thicker gloves and continue
  • (d) Unplug it and plug it back in

Answer: (b) Stop work, isolate the appliance and the circuit, and treat it as an earth fault — a live casing means protective earthing has failed — any shock from a casing is a serious fault, never a normal event.

Q9. Which fault finding situation always requires the supply to be isolated before testing?

  • (a) Measuring voltage at a socket
  • (b) Continuity, resistance and insulation resistance tests — these are dead tests
  • (c) Reading a clamp meter
  • (d) Pressing an RCD test button

Answer: (b) Continuity, resistance and insulation resistance tests — these are dead tests — voltage and clamp measurements are live tests; resistance, continuity and megger tests must be done with the circuit isolated and proved dead.

Q10. After fixing a fault, the circuit passes all tests but the customer reports the same symptom a week later. What does good practice require?

  • (a) Tell the customer it is their imagination
  • (b) Return, re-test under the conditions that produce the symptom, and check the original fault record for what was assumed rather than proven
  • (c) Charge for a completely new installation
  • (d) Replace the meter

Answer: (b) Return, re-test under the conditions that produce the symptom, and check the original fault record for what was assumed rather than proven — an intermittent fault may never have been present during the first test, so the diagnosis must be re-checked, not dismissed.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics