Electrical Troubleshooting MCQs — Set 1
10 practice questions on the systematic troubleshooting method — what to check first and how to narrow a fault down, with answers explained.
Q1. What is the correct FIRST step when an electrical circuit stops working?
- (a) Replace the most expensive component
- (b) Gather the symptoms and check the obvious — supply, switches, breakers and fuses
- (c) Strip all the wiring out and start again
- (d) Increase the breaker rating so it stops tripping
Answer: (b) Gather the symptoms and check the obvious — supply, switches, breakers and fuses — most faults are found by simple checks before any component is replaced.
Q2. A socket has 0 V between live and neutral, but the breaker is ON. What should you check next?
- (a) The load connected to the socket
- (b) Whether supply voltage is present at the breaker output feeding that circuit
- (c) The colour of the socket faceplate
- (d) The insulation resistance of the cable
Answer: (b) Whether supply voltage is present at the breaker output feeding that circuit — 0 V at the socket with the breaker on points to a supply-side fault, so work back toward the source.
Q3. Why should you reproduce the fault before you start testing?
- (a) To confirm exactly when and how it happens, so you test the right condition
- (b) To make the fault worse
- (c) To use up the customer’s patience
- (d) To avoid using a multimeter
Answer: (a) To confirm exactly when and how it happens, so you test the right condition — an intermittent fault that only appears under load cannot be found by testing a dead, unloaded circuit.
Q4. A fault affects only one room while the rest of the house works normally. What does this tell you?
- (a) The main supply to the house has failed
- (b) The fault is in that room’s circuit or its breaker, not the main supply
- (c) Every appliance in the house is faulty
- (d) The meter is faulty
Answer: (b) The fault is in that room’s circuit or its breaker, not the main supply — a fault limited to one circuit rules out the common supply feeding all circuits.
Q5. Which is the best order for fault-finding on a dead circuit?
- (a) Replace parts at random until it works
- (b) Supply → protection → switch → wiring → load, checking each stage in turn
- (c) Load → wiring → switch → protection → supply
- (d) Start with the most expensive part
Answer: (b) Supply → protection → switch → wiring → load, checking each stage in turn — working methodically from the source toward the load finds the first point where the expected value disappears.
Q6. A customer says “the lights flicker when the washing machine runs”. What is the most useful next question?
- (a) What colour are the walls?
- (b) Does it happen with any other heavy load, and did it start suddenly or gradually?
- (c) How old is the house paint?
- (d) What brand is the television?
Answer: (b) Does it happen with any other heavy load, and did it start suddenly or gradually? — the answer separates a loose connection or voltage-drop problem from one faulty appliance.
Q7. You measure 230 V at a socket with no load, but the voltage falls to 180 V when a 2 kW heater is plugged in. What does this indicate?
- (a) The heater is faulty
- (b) A high-resistance (loose or corroded) connection in the circuit, dropping voltage under load
- (c) The socket is wired correctly
- (d) The supply voltage is too high
Answer: (b) A high-resistance (loose or corroded) connection in the circuit, dropping voltage under load — a 2 kW heater draws 2,000 ÷ 230 = 8.7 A, and a poor joint drops far more voltage at 8.7 A than at no load.
Q8. Why is it wrong to keep resetting a breaker that trips immediately every time?
- (a) It wastes time
- (b) The fault is still present, and repeated resetting can overheat wiring and damage equipment
- (c) Breakers are designed to be reset 100 times
- (d) It makes the breaker stronger
Answer: (b) The fault is still present, and repeated resetting can overheat wiring and damage equipment — a breaker that trips instantly is reporting a fault; find and clear the fault first.
Q9. After a repair, what is the correct final step before handing the circuit back?
- (a) Leave the covers off for easy access
- (b) Test the circuit under normal load, check all functions, and record what was found and fixed
- (c) Tell the customer not to use it
- (d) Fit a larger fuse so it never trips again
Answer: (b) Test the circuit under normal load, check all functions, and record what was found and fixed — a repair is only complete when the circuit is proven working under load.
Q10. A circuit worked for years and suddenly fails after a storm. Which cause should you suspect first?
- (a) The cable has worn out from old age alone
- (b) Storm damage — water ingress, a fallen branch, or a surge affecting the supply or outdoor parts
- (c) The user changed the light bulbs
- (d) The meter reading is wrong
Answer: (b) Storm damage — water ingress, a fallen branch, or a surge affecting the supply or outdoor parts — a sudden failure linked to a recent event points to that event, not gradual wear.
Also read: GFCI Outlet Keeps Tripping | All MCQ Topics