Three-Phase Motor MCQs — Set 10

10 practice questions on braking, reversing, special running effects and applications of three-phase motors, with answers.

Q1. What is plugging as a braking method for an induction motor?

  • (a) Disconnecting the motor and letting it coast to a stop
  • (b) Reversing the phase sequence so the motor develops torque against its rotation
  • (c) Applying DC to the stator
  • (d) Short-circuiting the rotor

Answer: (b) Reversing the phase sequence so the motor develops torque against its rotation — the reversed field brakes the motor quickly, but the supply must be cut at zero speed or the motor runs backwards.

Q2. What is DC injection braking?

  • (a) Feeding DC into the stator after the AC supply is removed, to hold the rotor still
  • (b) Injecting DC into the rotor bars
  • (c) Charging the motor with a battery
  • (d) Reversing two supply phases

Answer: (a) Feeding DC into the stator after the AC supply is removed, to hold the rotor still — the stationary DC field induces currents in the moving rotor that oppose its motion and bring it to a smooth stop.

Q3. What is crawling in an induction motor?

  • (a) Running at full speed
  • (b) Running steadily at a very low speed, about one-seventh of synchronous speed, due to harmonics
  • (c) Vibrating at standstill
  • (d) Overheating at no load

Answer: (b) Running steadily at a very low speed, about one-seventh of synchronous speed, due to harmonics — the 7th harmonic produces a torque that holds the motor near Ns ÷ 7, so it crawls instead of running up.

Q4. What is cogging in an induction motor?

  • (a) The motor refusing to start because stator and rotor slots align and lock magnetically
  • (b) The motor running too fast
  • (c) The motor drawing excess current at full load
  • (d) The motor reversing on its own

Answer: (a) The motor refusing to start because stator and rotor slots align and lock magnetically — when stator and rotor slot numbers are equal, magnetic locking can hold the rotor still, so slots are usually skewed to prevent it.

Q5. How is the speed of a pole-changing (Dahlander) motor changed?

  • (a) By changing the supply voltage
  • (b) By reconnecting the stator winding to give a different number of poles
  • (c) By adding rotor resistance
  • (d) By changing the rotor bars

Answer: (b) By reconnecting the stator winding to give a different number of poles — for example, a 4-pole/8-pole motor runs at 1,500 rpm or 750 rpm on 50 Hz, giving two fixed speeds.

Q6. What is inching (jogging) of a motor?

  • (a) Running the motor continuously at full load
  • (b) Starting the motor in short pulses to move the load a small distance at a time
  • (c) Reversing the motor at full speed
  • (d) Braking the motor with DC

Answer: (b) Starting the motor in short pulses to move the load a small distance at a time — jogging is used to position machinery precisely, but repeated starts heat the motor.

Q7. For a fan or pump load, how does the load torque vary with speed?

  • (a) It stays constant at all speeds
  • (b) It rises roughly with the square of speed
  • (c) It falls as speed rises
  • (d) It varies with the cube of speed

Answer: (b) It rises roughly with the square of speed — fan torque follows speed squared (power follows speed cubed), which is why VFD speed control saves so much energy on fans.

Q8. What type of load needs nearly constant torque at all speeds?

  • (a) A fan
  • (b) A conveyor belt or hoist
  • (c) A centrifugal pump
  • (d) A propeller

Answer: (b) A conveyor belt or hoist — the load torque comes mainly from friction and gravity, so it stays nearly the same whatever the speed.

Q9. Why is a flameproof (explosion-proof) motor used in hazardous areas?

  • (a) It is more efficient
  • (b) Its enclosure contains any internal explosion so it cannot ignite gas or dust outside
  • (c) It runs cooler than other motors
  • (d) It needs no maintenance

Answer: (b) Its enclosure contains any internal explosion so it cannot ignite gas or dust outside — flameproof motors are built for mines, refineries and chemical plants.

Q10. A 6-pole motor is supplied at 50 Hz and runs at 960 rpm. What is its percentage slip?

  • (a) 2%
  • (b) 4%
  • (c) 5%
  • (d) 6%

Answer: (b) 4% — Ns = 1,000 rpm, so s = (1,000 − 960) ÷ 1,000 = 40 ÷ 1,000 = 0.04 = 4%.