Three-Phase Motor MCQs — Set 9
10 practice questions on motor nameplates, testing and selection of three-phase motors, with answers.
Q1. What does the full-load current (FLC) on a motor nameplate tell you?
- (a) The starting current
- (b) The current the motor draws when delivering its rated output at rated voltage
- (c) The no-load current
- (d) The short-circuit current
Answer: (b) The current the motor draws when delivering its rated output at rated voltage — FLC is the basis for sizing cables, overloads and starters.
Q2. What does a no-load test on an induction motor mainly measure?
- (a) The full-load torque
- (b) The iron loss plus friction and windage loss
- (c) The rotor copper loss at full load
- (d) The insulation resistance
Answer: (b) The iron loss plus friction and windage loss — at no load the motor draws mainly magnetising current, so the input power covers core and mechanical losses.
Q3. What does a blocked-rotor (locked-rotor) test mainly determine?
- (a) The no-load current
- (b) The starting current, starting power factor and rotor resistance at standstill
- (c) The insulation class
- (d) The efficiency at full load
Answer: (b) The starting current, starting power factor and rotor resistance at standstill — with the rotor locked, the test reproduces starting conditions at reduced voltage.
Q4. How is the continuity of a motor winding checked in the field?
- (a) With a megger only
- (b) With a multimeter on resistance range — an open circuit shows infinite resistance
- (c) By measuring the supply voltage
- (d) By checking the frame size
Answer: (b) With a multimeter on resistance range — an open circuit shows infinite resistance — each phase winding should show a low, roughly equal resistance.
Q5. What does duty type S1 on a motor nameplate mean?
- (a) Short-time duty
- (b) Continuous running duty at constant load until thermal equilibrium
- (c) Intermittent duty
- (d) Starting duty only
Answer: (b) Continuous running duty at constant load until thermal equilibrium — S1 motors, such as fan and pump motors, run non-stop at rated load.
Q6. What does a service factor of 1.15 on a motor mean?
- (a) The motor can be overloaded by 15% continuously without damage
- (b) The motor is 15% efficient
- (c) The motor has 15% slip
- (d) The motor runs 15% faster than rated
Answer: (a) The motor can be overloaded by 15% continuously without damage — a 1.15 service factor allows 15% above rated output, though running there shortens motor life.
Q7. A motor nameplate reads 400 V delta / 690 V star. What does this mean?
- (a) It can run on either supply if connected correctly — 400 V in delta or 690 V in star
- (b) It must always be star connected
- (c) It is a single-phase motor
- (d) It needs 690 V in delta
Answer: (a) It can run on either supply if connected correctly — 400 V in delta or 690 V in star — in both cases each winding sees 400 V (690 ÷ √3 = 400 V).
Q8. Why are the resistances of the three stator windings compared during testing?
- (a) To check the paint colour
- (b) To detect a shorted turn or a bad connection — all three should be nearly equal
- (c) To measure the supply frequency
- (d) To find the number of poles
Answer: (b) To detect a shorted turn or a bad connection — all three should be nearly equal — a winding with much lower resistance may have shorted turns, and a higher one a loose joint.
Q9. Before starting a motor after a long shutdown in a damp place, what test is most important?
- (a) A speed test
- (b) An insulation-resistance test, to check the windings are dry
- (c) A torque test
- (d) A vibration test
Answer: (b) An insulation-resistance test, to check the windings are dry — damp insulation can break down to earth when voltage is applied, so it must be checked and dried first.
Q10. When selecting a motor for a load, which factor decides the required frame size?
- (a) The colour of the motor
- (b) The rated power and speed — larger power at lower speed needs a larger frame
- (c) The supply frequency only
- (d) The length of the cable
Answer: (b) The rated power and speed — larger power at lower speed needs a larger frame — frame size standardises the shaft height, mounting and overall dimensions for a given output.