Testing and Commissioning MCQs — Set 7

10 practice questions on functional and load testing — proving the installation actually works under real operating conditions.

Q1. What does a functional test check?

  • (a) The colour of the cables
  • (b) That switches, breakers, controls and equipment actually operate as intended
  • (c) The length of the cable run
  • (d) The brand of the fittings

Answer: (b) That switches, breakers, controls and equipment actually operate as intended — functional testing means switching things on and off and confirming they do what they should.

Q2. What is a load test?

  • (a) Running the circuit at or near its normal load and checking voltage, current and heating
  • (b) Weighing the cable drum
  • (c) Counting the number of sockets
  • (d) Testing with the supply switched off

Answer: (a) Running the circuit at or near its normal load and checking voltage, current and heating — a circuit can pass dead tests yet fail under load, so it must be proven while working.

Q3. A 230 V circuit is insulation-tested at 500 V DC and reads 0.5 MΩ. What does this mean?

  • (a) The insulation is good
  • (b) The insulation is below the 1 MΩ minimum and the circuit must be investigated
  • (c) The test voltage was too low
  • (d) The circuit is ready for use

Answer: (b) The insulation is below the 1 MΩ minimum and the circuit must be investigated — insulation resistance must be above 1 MΩ at 500 V DC, so 0.5 MΩ is a fail and the fault must be found before the circuit is used.

Q4. Under the NEC 80% rule, what is the maximum safe continuous load on a 15 A, 120 V circuit?

  • (a) 1,800 W
  • (b) 1,500 W
  • (c) 1,200 W
  • (d) 1,440 W

Answer: (d) 1,440 W — the full rating is 15 × 120 = 1,800 W, and 80% of that is 1,800 × 0.8 = 1,440 W for continuous loads.

Q5. A 230 V circuit is allowed a 3% voltage drop. What is the maximum permitted drop in volts?

  • (a) 6.9 V
  • (b) 3.0 V
  • (c) 2.3 V
  • (d) 23 V

Answer: (a) 6.9 V — 3% of 230 V is 230 × 0.03 = 6.9 V, so the voltage at the load must not fall below 230 − 6.9 = 223.1 V.

Q6. What does a thermal imaging camera reveal during load testing?

  • (a) The colour of the wires
  • (b) Hot spots from loose connections or overloaded cables before they fail
  • (c) The voltage at each socket
  • (d) The age of the installation

Answer: (b) Hot spots from loose connections or overloaded cables before they fail — a loose terminal heats up under load and shows as a bright spot on the thermal image.

Q7. Why is a circuit tested under load, not just with dead tests?

  • (a) Dead tests take too long
  • (b) Load testing uses no instruments
  • (c) Some faults, such as heating at a loose joint or excessive voltage drop, only appear when current flows
  • (d) The client prefers it

Answer: (c) Some faults, such as heating at a loose joint or excessive voltage drop, only appear when current flows — dead tests cannot show how the circuit behaves while working.

Q8. When commissioning a three-phase motor, what must be checked at start-up?

  • (a) Only the paint colour of the motor
  • (b) Only the length of the cable
  • (c) Only the size of the starter box
  • (d) That it rotates in the correct direction and its running current matches the nameplate rating

Answer: (d) That it rotates in the correct direction and its running current matches the nameplate rating — wrong rotation or excess current means a wiring or load problem that must be fixed before handover.

Q9. A motor rated at 10 A full-load current draws 9.5 A when running normally. What does this indicate?

  • (a) The motor is faulty and must be replaced
  • (b) The motor is running normally, just below its full-load rating
  • (c) The supply voltage is zero
  • (d) The motor is about to burn out

Answer: (b) The motor is running normally, just below its full-load rating — a running current close to, but not above, the nameplate value is expected for a healthy motor on its normal load.

Q10. Lights flicker noticeably when a large load on the same circuit switches on. What does this most likely indicate?

  • (a) The lamps are new
  • (b) A loose connection or excessive voltage drop on that circuit
  • (c) The supply frequency has changed
  • (d) The lamps are the wrong colour

Answer: (b) A loose connection or excessive voltage drop on that circuit — a heavy load pulls the voltage down, and a loose joint makes the drop much worse; both show up as flicker.