Synchronous Motor MCQs — Set 7
10 practice questions comparing synchronous motors with induction motors — constant speed, applications and disadvantages.
Q1. How does the speed of a synchronous motor change when the load increases?
- (a) It drops by 5%
- (b) It drops slightly, like an induction motor
- (c) It stays constant at synchronous speed
- (d) It increases
Answer: (c) It stays constant at synchronous speed — the rotor stays locked to the stator field whatever the load, until pull-out torque is exceeded.
Q2. How does the speed of an induction motor change when the load increases?
- (a) It stays exactly constant
- (b) It drops slightly as the slip increases
- (c) It increases
- (d) It falls to zero
Answer: (b) It drops slightly as the slip increases — an induction motor must slip to develop torque, so more load means more slip and lower speed.
Q3. Synchronous motors are commonly used to drive which of these?
- (a) Small domestic fans
- (b) Constant-speed loads such as compressors, pumps, mills and crushers
- (c) Hand drills
- (d) Toys
Answer: (b) Constant-speed loads such as compressors, pumps, mills and crushers — their constant speed and power factor correction ability suit large industrial drives.
Q4. Which type of motor needs a DC excitation supply for its rotor?
- (a) Squirrel-cage induction motor
- (b) Synchronous motor
- (c) Slip-ring induction motor
- (d) Single-phase induction motor
Answer: (b) Synchronous motor — its rotor field winding must be fed with DC through slip rings, or from a brushless exciter.
Q5. Which motor is self-starting?
- (a) Synchronous motor
- (b) Induction motor
- (c) Neither is self-starting
- (d) Both need a pony motor
Answer: (b) Induction motor — an induction motor develops starting torque on its own, while a synchronous motor needs a starting aid.
Q6. At low speeds, how does the efficiency of a synchronous motor compare with an induction motor of the same rating?
- (a) Lower, because of the excitation losses
- (b) Higher, because there is no rotor copper loss from slip at synchronous speed
- (c) Exactly the same
- (d) Zero, because it cannot run at low speed
Answer: (b) Higher, because there is no rotor copper loss from slip at synchronous speed — this makes synchronous motors attractive for large low-speed drives.
Q7. Why are synchronous motors preferred for large low-speed drives?
- (a) They are the cheapest option
- (b) They give constant speed, higher efficiency at low speed and can correct the power factor
- (c) They need no maintenance
- (d) They run on DC supply
Answer: (b) They give constant speed, higher efficiency at low speed and can correct the power factor — these three benefits together justify their higher cost on large drives.
Q8. Which motor has no slip rings and brushes in its common squirrel-cage form?
- (a) Synchronous motor
- (b) Squirrel-cage induction motor
- (c) DC shunt motor
- (d) Wound-rotor synchronous motor
Answer: (b) Squirrel-cage induction motor — its rotor is a short-circuited cage with no external connections, unlike a synchronous motor’s field winding.
Q9. Why are small synchronous motors used in electric clocks and timing devices?
- (a) They are very powerful
- (b) They run at a speed locked exactly to the supply frequency, so they keep accurate time
- (c) They are self-starting
- (d) They need no supply at all
Answer: (b) They run at a speed locked exactly to the supply frequency, so they keep accurate time — the speed depends only on frequency and pole number, not on load.
Q10. What is the main disadvantage of a synchronous motor compared with an induction motor?
- (a) Its speed varies with load
- (b) It is not self-starting, needs a DC excitation supply and costs more
- (c) It cannot run on AC supply
- (d) It has a very low efficiency
Answer: (b) It is not self-starting, needs a DC excitation supply and costs more — these are the main reasons induction motors are used for most general drives.
Also read: Dynamo vs Alternator | All MCQ Topics