Synchronous Motor MCQs — Set 3

10 practice questions on synchronous motor excitation — V-curves, under-excitation, over-excitation and power factor.

Q1. An over-excited synchronous motor draws what kind of current from the supply?

  • (a) Lagging current
  • (b) Leading current
  • (c) Unity power factor current only
  • (d) No current at all

Answer: (b) Leading current — over-excitation makes the motor supply reactive power, so its current leads the voltage.

Q2. An under-excited synchronous motor draws what kind of current?

  • (a) Leading current
  • (b) Lagging current
  • (c) Zero current
  • (d) Direct current

Answer: (b) Lagging current — with weak field excitation the motor absorbs reactive power, so its current lags the voltage.

Q3. What does a V-curve of a synchronous motor plot?

  • (a) Speed against load
  • (b) Armature current against field current at constant load
  • (c) Torque against speed
  • (d) Power factor against load

Answer: (b) Armature current against field current at constant load — the curve is V-shaped, with minimum current at unity power factor.

Q4. At what point is the armature current of a synchronous motor at its minimum for a given load?

  • (a) At maximum excitation
  • (b) At minimum excitation
  • (c) At unity power factor
  • (d) At zero excitation

Answer: (c) At unity power factor — at unity power factor the current is purely active, so it is the smallest possible for that load.

Q5. What is “normal excitation” of a synchronous motor?

  • (a) The excitation that gives zero power factor
  • (b) The excitation that gives unity power factor
  • (c) The excitation that gives maximum current
  • (d) The excitation at no load only

Answer: (b) The excitation that gives unity power factor — this is also called critical excitation.

Q6. At constant load, if the field current is increased gradually from a low value, what happens to the power factor?

  • (a) It stays lagging throughout
  • (b) It changes from lagging to unity and then to leading
  • (c) It changes from leading to unity and then to lagging
  • (d) It stays at unity throughout

Answer: (b) It changes from lagging to unity and then to leading — under-excitation is lagging, normal excitation is unity, over-excitation is leading.

Q7. What does an inverted V-curve of a synchronous motor plot?

  • (a) Armature current against field current
  • (b) Power factor against field current at constant load
  • (c) Speed against field current
  • (d) Torque against field current

Answer: (b) Power factor against field current at constant load — the curve peaks at unity power factor at normal excitation.

Q8. What is critical excitation?

  • (a) The excitation at which the motor loses synchronism
  • (b) The excitation that gives unity power factor
  • (c) The excitation at which hunting starts
  • (d) The maximum safe field current

Answer: (b) The excitation that gives unity power factor — below it the motor is under-excited (lagging), above it over-excited (leading).

Q9. An over-excited synchronous motor running at no load behaves like what device?

  • (a) An induction motor
  • (b) A synchronous capacitor (condenser)
  • (c) A transformer
  • (d) A resistor

Answer: (b) A synchronous capacitor (condenser) — at no load with over-excitation it draws leading current and supplies reactive power, like a capacitor.

Q10. At constant load, if the excitation is increased beyond normal, what happens to the armature current?

  • (a) It keeps decreasing
  • (b) It first decreases to a minimum, then increases again
  • (c) It stays constant
  • (d) It falls to zero

Answer: (b) It first decreases to a minimum, then increases again — that minimum occurs at unity power factor; further excitation raises the leading reactive current.

Also read: Dynamo vs Alternator | All MCQ Topics