Switchgear MCQs — Set 8

10 practice questions on switchgear protection and control — relays, DC trip circuits, interlocks, auto-reclosers and SCADA, with answers and explanations.

Q1. What is the function of a protective relay in switchgear?

  • (a) To interrupt the fault current itself
  • (b) To detect the fault and send a trip signal to the circuit breaker
  • (c) To measure the load
  • (d) To earth the busbar

Answer: (b) To detect the fault and send a trip signal to the circuit breaker — the relay senses abnormal current or voltage and orders the breaker to open.

Q2. Trip circuits in switchgear are usually supplied from:

  • (a) The AC mains only
  • (b) A DC battery
  • (c) A solar panel
  • (d) The CT secondary

Answer: (b) A DC battery — a battery-backed DC supply keeps protection working even when the AC supply fails.

Q3. Why is DC preferred for breaker trip and control circuits?

  • (a) DC is cheaper to generate
  • (b) The battery keeps protection alive during a fault or AC supply failure
  • (c) DC breakers are smaller
  • (d) Relays work only on DC

Answer: (b) The battery keeps protection alive during a fault or AC supply failure — a fault can collapse the AC voltage, but the battery still trips the breaker.

Q4. What is the purpose of an interlock in switchgear?

  • (a) To increase the fault current
  • (b) To prevent an unsafe or wrong switching sequence
  • (c) To cool the breaker
  • (d) To measure insulation resistance

Answer: (b) To prevent an unsafe or wrong switching sequence — for example, stopping an isolator from opening on load or an earthing switch from closing onto a live circuit.

Q5. What does SCADA do in a modern substation?

  • (a) Generates power
  • (b) Allows remote monitoring and control of switchgear
  • (c) Replaces the circuit breaker
  • (d) Supplies the load directly

Answer: (b) Allows remote monitoring and control of switchgear — operators can see breaker status and switch feeders from a control centre.

Q6. An overcurrent relay trips the breaker when:

  • (a) The voltage rises
  • (b) The current exceeds its set value for a set time
  • (c) The frequency falls
  • (d) The temperature falls

Answer: (b) The current exceeds its set value for a set time — the time delay lets the relay grade with downstream protection.

Q7. An earth-fault relay detects:

  • (a) Overvoltage
  • (b) Current leaking to earth
  • (c) Over-frequency
  • (d) High power factor

Answer: (b) Current leaking to earth — it senses the residual current that flows when a phase touches earth.

Q8. What does breaker-failure protection do?

  • (a) Repairs the breaker
  • (b) If a breaker fails to clear a fault, it trips the adjacent breakers
  • (c) Prevents the breaker from closing
  • (d) Increases the breaking capacity

Answer: (b) If a breaker fails to clear a fault, it trips the adjacent breakers — it is the backup that stops a stuck breaker from leaving a fault on the system.

Q9. What is an auto-recloser?

  • (a) A device that recloses a breaker automatically after a transient fault, to restore supply
  • (b) A manual isolator
  • (c) A type of CT
  • (d) A battery charger

Answer: (a) A device that recloses a breaker automatically after a transient fault, to restore supply — most overhead-line faults are temporary, such as a lightning flashover.

Q10. On a switchgear panel, the standard indication is:

  • (a) Red lamp = breaker open, green lamp = breaker closed
  • (b) Red lamp = breaker closed, green lamp = breaker open
  • (c) Red lamp = earth fault only
  • (d) Green lamp = breaker tripped

Answer: (b) Red lamp = breaker closed, green lamp = breaker open — red means the circuit is live and dangerous, green means it is open and safe.

Also read: Breaker and Protection MCQs | All MCQ Topics