Surge Protection MCQs — Set 10

10 scenario questions on surge protection in real installations — whole-house versus point-of-use protection, solar PV, data lines and storms.

Q1. A house has expensive electronics in every room. Which approach protects them all?

  • (a) A whole-house Type 2 SPD in the main distribution board, with Type 3 SPDs at the most sensitive equipment
  • (b) A single Type 3 SPD at one television only
  • (c) A larger MCB on the main switch
  • (d) Thicker cables with no SPD at all

Answer: (a) A whole-house Type 2 SPD in the main distribution board, with Type 3 SPDs at the most sensitive equipment — the board SPD guards every circuit, and the point-of-use SPDs give the final fine clamping.

Q2. A homeowner buys a plug-in surge-protected extension strip for a computer. What kind of SPD is this?

  • (a) A Type 3 point-of-use SPD
  • (b) A Type 1 lightning-current SPD
  • (c) An MCB
  • (d) An RCCB

Answer: (a) A Type 3 point-of-use SPD — it sits at the equipment and handles only the small residual surge left after any upstream protection.

Q3. Why can a plug-in surge strip not protect a whole house on its own?

  • (a) It is rated only for small residual surges at one outlet, and other circuits have no protection at all
  • (b) It cannot be plugged into a wall socket
  • (c) It only works when the computer is switched on
  • (d) It protects the whole house automatically by itself

Answer: (a) It is rated only for small residual surges at one outlet, and other circuits have no protection at all — a strip guards its own sockets, nothing else in the building.

Q4. A building has a solar PV system. Why does its DC side also need surge protection?

  • (a) Lightning and switching surges can enter through the PV array cables and damage the inverter
  • (b) Solar panels generate surges in bright sunlight
  • (c) The inverter needs a higher voltage than the panels produce
  • (d) DC circuits can never suffer surges

Answer: (a) Lightning and switching surges can enter through the PV array cables and damage the inverter — long outdoor DC runs are exposed, so a DC-rated SPD is fitted on the PV side.

Q5. Besides the mains supply, which other incoming lines can carry a surge into a building?

  • (a) Telephone, data and antenna lines
  • (b) Only the mains supply can carry a surge
  • (c) Only the water supply can carry a surge
  • (d) Only the gas supply can carry a surge

Answer: (a) Telephone, data and antenna lines — any long conductor entering the building can pick up a transient, so data-line SPDs protect routers and telecom equipment.

Q6. A lightning rod (air terminal) is fitted on a roof. Does it remove the need for SPDs?

  • (a) No — the rod handles the direct strike, but surges still travel in on supply and data lines, so SPDs are still needed
  • (b) Yes — a lightning rod stops all surges everywhere
  • (c) Yes — but only if the rod is painted white
  • (d) No — a lightning rod attracts surges into the sockets

Answer: (a) No — the rod handles the direct strike, but surges still travel in on supply and data lines, so SPDs are still needed — external and internal lightning protection do different jobs.

Q7. During a severe thunderstorm, what is the most reliable way to protect a valuable computer?

  • (a) Unplug it from the mains and data lines, in addition to having SPDs fitted
  • (b) Leave it switched on with no SPD, because storms never damage computers
  • (c) Cover it with a blanket
  • (d) Switch it off but leave it plugged in, with no SPD

Answer: (a) Unplug it from the mains and data lines, in addition to having SPDs fitted — physical disconnection removes the surge path entirely; SPDs reduce risk but cannot guarantee protection against a direct strike.

Q8. A fridge control board keeps failing after storms while the fridge compressor survives. What is the most likely explanation?

  • (a) Surges are damaging the sensitive electronic board, while the rugged compressor motor tolerates them
  • (b) The fridge is too cold
  • (c) The compressor is generating the surges itself
  • (d) The board fails because of low voltage only

Answer: (a) Surges are damaging the sensitive electronic board, while the rugged compressor motor tolerates them — semiconductor boards break down at far lower voltages than motors.

Q9. When choosing an SPD for a 230 V home, which three ratings must match the installation?

  • (a) Uc above 230 V, a low Up, and In/Imax suited to the expected surges
  • (b) Uc below 230 V, a high Up, and the lowest possible In
  • (c) Only the colour of the SPD casing
  • (d) Only the brand name of the SPD

Answer: (a) Uc above 230 V, a low Up, and In/Imax suited to the expected surges — Uc must clear the supply, Up must be low enough to protect the equipment, and the current ratings must cover the surge size.

Q10. A new house is being wired in a lightning-prone area. What is the best surge-protection plan?

  • (a) Type 1 SPD at the service entrance, Type 2 SPD in the distribution board, and Type 3 SPDs at sensitive equipment
  • (b) A Type 3 SPD at the service entrance only
  • (c) No SPDs at all, because new wiring cannot suffer surges
  • (d) A fuse at the service entrance instead of any SPD

Answer: (a) Type 1 SPD at the service entrance, Type 2 SPD in the distribution board, and Type 3 SPDs at sensitive equipment — the staged system handles the lightning current first and refines the protection at each step.

Also read: AFCI Breaker Keeps Tripping | All MCQ Topics