Surge Protection MCQs — Set 7

10 practice questions comparing SPDs with MCBs, RCCBs and fuses — what each device protects against and why they work together, not alone.

Q1. What does an MCB protect against?

  • (a) Overload and short-circuit overcurrent
  • (b) Transient overvoltage surges
  • (c) Earth leakage current
  • (d) Loss of supply frequency

Answer: (a) Overload and short-circuit overcurrent — an MCB trips when the current exceeds its rating for too long or rises suddenly in a fault.

Q2. What does a 30 mA RCCB protect against?

  • (a) Electric shock from earth leakage current of 30 mA and above
  • (b) Lightning surges of 30 kA
  • (c) Overload currents of 30 A
  • (d) Voltage surges of 30 V

Answer: (a) Electric shock from earth leakage current of 30 mA and above — the RCCB detects current leaking to earth and trips in milliseconds.

Q3. Why can an MCB not protect equipment from a voltage surge?

  • (a) It responds to current, not voltage, and it is far too slow for a microsecond surge
  • (b) It is always switched off during a surge
  • (c) It only works on DC supplies
  • (d) It absorbs surges into its contacts

Answer: (a) It responds to current, not voltage, and it is far too slow for a microsecond surge — the surge is over before the MCB’s mechanism can move.

Q4. Why can a fuse not replace an SPD?

  • (a) A fuse only opens on excess current; it cannot clamp a high voltage that flows at low current
  • (b) A fuse always blows at 230 V
  • (c) A fuse conducts surges to earth
  • (d) A fuse is too fast to catch a surge

Answer: (a) A fuse only opens on excess current; it cannot clamp a high voltage that flows at low current — a surge can reach kilovolts while drawing little current through the fuse.

Q5. Does an SPD protect a circuit against overload?

  • (a) No — an SPD only limits transient overvoltage; overload protection is the MCB’s job
  • (b) Yes — an SPD trips on overload just like an MCB
  • (c) Yes — but only on overloads above 40 kA
  • (d) No — an SPD protects against overload only on Sundays

Answer: (a) No — an SPD only limits transient overvoltage; overload protection is the MCB’s job — each device has one job, and the SPD’s job is voltage, not current.

Q6. A lightning surge passes through a circuit protected only by an MCB. What is the likely result?

  • (a) The surge reaches the equipment undiminished, because the MCB does not clamp voltage
  • (b) The MCB clamps the surge to a safe voltage
  • (c) The MCB diverts the surge to earth
  • (d) The MCB absorbs the surge energy harmlessly

Answer: (a) The surge reaches the equipment undiminished, because the MCB does not clamp voltage — the MCB stays closed through the microsecond event and the equipment takes the full spike.

Q7. Why is a backup overcurrent device (MCB or fuse) fitted in series with an SPD?

  • (a) To disconnect a failed, short-circuited SPD from the supply safely
  • (b) To make the SPD clamp faster
  • (c) To increase the SPD’s Imax rating
  • (d) To supply power to the SPD indicator lamp

Answer: (a) To disconnect a failed, short-circuited SPD from the supply safely — if an MOV fails short, the backup device clears it before it causes a fire.

Q8. Which device trips when a person touches a live part and 30 mA leaks to earth?

  • (a) The RCCB
  • (b) The SPD
  • (c) The surge strip
  • (d) The voltmeter

Answer: (a) The RCCB — the SPD does not detect earth leakage at all; only the RCCB measures the imbalance between line and neutral currents.

Q9. Which combination gives complete protection against surges, overloads and electric shock?

  • (a) SPD + MCB + RCCB, each doing its own job
  • (b) SPD alone
  • (c) MCB alone
  • (d) RCCB alone

Answer: (a) SPD + MCB + RCCB, each doing its own job — the SPD clamps voltage, the MCB clears overcurrent, and the RCCB clears earth leakage.

Q10. A circuit has an SPD but no MCB. A short circuit occurs in the load. What happens?

  • (a) Nothing trips on overcurrent, because the SPD does not respond to short-circuit current
  • (b) The SPD trips instantly on the short circuit
  • (c) The SPD clamps the short-circuit current to 30 mA
  • (d) The SPD becomes an MCB automatically

Answer: (a) Nothing trips on overcurrent, because the SPD does not respond to short-circuit current — the fault current would flow unchecked without an MCB or fuse.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics