Q1. What is resonance in a stepper motor?

  • (a) The motor singing at mains frequency
  • (b) Vibration that builds up when the step rate matches the motor-load system’s natural frequency, causing oscillation and missed steps
  • (c) The sound of the bearings failing
  • (d) Electrical noise from the power supply

Answer: (b) Vibration that builds up when the step rate matches the motor-load system’s natural frequency, causing oscillation and missed steps — at resonance the rotor overshoots each step and can fall out of synchronism.

Q2. Which of these reduces resonance and vibration in a stepper motor?

  • (a) Running only at full-step mode
  • (b) Microstepping, mechanical damping, or avoiding the resonant speed range
  • (c) Removing the driver
  • (d) Increasing the load suddenly

Answer: (b) Microstepping, mechanical damping, or avoiding the resonant speed range — finer steps excite the resonance less, and damping absorbs the oscillation.

Q3. What limits the maximum speed of a stepper motor?

  • (a) The number of wires
  • (b) Winding inductance and back EMF, which prevent the current reaching full value at high step rates
  • (c) The colour of the motor casing
  • (d) The length of the shaft

Answer: (b) Winding inductance and back EMF, which prevent the current reaching full value at high step rates — as pulses get shorter, less current builds up, so torque falls until the motor can no longer follow.

Q4. Why is acceleration ramping used when starting a stepper motor?

  • (a) To increase the step angle
  • (b) To let the rotor build up speed gradually so it does not lose steps by being asked to jump instantly to full speed
  • (c) To reduce the supply voltage
  • (d) To change the direction

Answer: (b) To let the rotor build up speed gradually so it does not lose steps by being asked to jump instantly to full speed — the rotor’s inertia means it cannot follow a sudden high pulse rate.

Q5. A stepper motor is started suddenly at a pulse rate above its pull-in rate. What is likely to happen?

  • (a) It will start smoothly
  • (b) It will stall or vibrate in place without rotating
  • (c) Its step angle will halve
  • (d) It will run in reverse

Answer: (b) It will stall or vibrate in place without rotating — above the pull-in rate the rotor cannot synchronise with the stepping field from a standstill.

Q6. A 200-step-per-revolution motor receives 600 pulses per second. What is its speed in rpm?

  • (a) 60 rpm
  • (b) 120 rpm
  • (c) 180 rpm
  • (d) 300 rpm

Answer: (c) 180 rpm — 600 ÷ 200 = 3 rev/s, and 3 × 60 = 180 rpm.

Q7. What is the typical step accuracy of a stepper motor?

  • (a) Exactly 0% error on every step
  • (b) About ±5% of one step, and the error does not accumulate from step to step
  • (c) About ±50% of one step
  • (d) The error doubles with every revolution

Answer: (b) About ±5% of one step, and the error does not accumulate from step to step — each step is positioned relative to the magnetic field, so small errors do not add up over many steps.

Q8. Why does a stepper motor’s position error NOT accumulate over many steps?

  • (a) Because an encoder corrects it
  • (b) Because each step position is set by the magnetic field, not added onto the previous step’s error
  • (c) Because the motor is re-homed after every step
  • (d) Because steppers never make errors

Answer: (b) Because each step position is set by the magnetic field, not added onto the previous step’s error — the rotor is pulled to the next detent position each time, so errors stay within a fraction of one step.

Q9. At which speeds is a stepper motor usually noisiest and most prone to vibration?

  • (a) At very high speeds only
  • (b) At low to medium speeds in full-step mode, especially near resonance
  • (c) Only when switched off
  • (d) At standstill with no current

Answer: (b) At low to medium speeds in full-step mode, especially near resonance — the large, jerky full steps excite mechanical oscillation most strongly in this range.

Q10. A stepper motor runs smoothly at 100 rpm but vibrates badly at 200 rpm and runs smoothly again at 300 rpm. What is the most likely cause?

  • (a) A faulty power supply
  • (b) Resonance at around 200 rpm
  • (c) The wrong step angle
  • (d) A broken rotor tooth

Answer: (b) Resonance at around 200 rpm — a narrow speed band with bad vibration, smooth on both sides of it, is the classic sign of resonance.

Also read: DC Motor Calculator | All MCQ Topics