Stepper Motor MCQs — Set 5

10 practice questions on stepper motor torque — holding torque, detent torque, pull-in and pull-out torque, and what happens when the load is too big.

Q1. What is holding torque in a stepper motor?

  • (a) The torque produced at maximum speed
  • (b) The torque the motor can resist at standstill while its windings are energised at rated current
  • (c) The torque with no power applied
  • (d) The torque needed to start the motor

Answer: (b) The torque the motor can resist at standstill while its windings are energised at rated current — it is the motor’s ability to hold its position against an external load.

Q2. What is detent torque in a stepper motor?

  • (a) The torque at full speed
  • (b) The small torque that holds the rotor in place when no power is applied, due to the permanent magnet
  • (c) The torque needed to overcome friction at start-up
  • (d) The torque produced by the driver

Answer: (b) The small torque that holds the rotor in place when no power is applied, due to the permanent magnet — it is why a permanent-magnet or hybrid stepper resists turning by hand even when switched off.

Q3. What is pull-out torque?

  • (a) The maximum torque the motor can deliver while running at a given speed without losing steps
  • (b) The torque at standstill
  • (c) The torque with no power
  • (d) The starting torque of an unloaded motor

Answer: (a) The maximum torque the motor can deliver while running at a given speed without losing steps — exceed it and the motor stalls or misses steps.

Q4. What is pull-in torque?

  • (a) The torque at maximum speed
  • (b) The maximum load torque from which the motor can start and synchronise without losing steps
  • (c) The torque when the motor is switched off
  • (d) The torque of the driver circuit

Answer: (b) The maximum load torque from which the motor can start and synchronise without losing steps — a motor started against a load above its pull-in torque will not start cleanly.

Q5. How does a stepper motor’s torque change as its speed increases?

  • (a) It stays constant
  • (b) It increases
  • (c) It falls, because the winding inductance limits how fast current can build up
  • (d) It falls to zero immediately

Answer: (c) It falls, because the winding inductance limits how fast current can build up — at high step rates each pulse is too short for the current to reach its full value.

Q6. If the winding current of a stepper motor is increased (within its rating), what happens to its torque?

  • (a) Torque decreases
  • (b) Torque increases, because torque is roughly proportional to current
  • (c) Torque stays the same
  • (d) The step angle changes

Answer: (b) Torque increases, because torque is roughly proportional to current — more current means a stronger magnetic field in the windings.

Q7. What happens if a stepper motor is driven with current well above its rated value?

  • (a) It runs cooler
  • (b) It overheats, and the magnets can be permanently weakened
  • (c) Its step angle becomes smaller
  • (d) Nothing changes

Answer: (b) It overheats, and the magnets can be permanently weakened — excess current causes extra I²R heating in the windings and can demagnetise the rotor.

Q8. A stepper motor is asked to move a load heavier than its pull-out torque. What will happen?

  • (a) It will move faster
  • (b) It will miss steps or stall, and its final position will be wrong
  • (c) Its step angle will double
  • (d) It will reverse direction

Answer: (b) It will miss steps or stall, and its final position will be wrong — in an open-loop system the controller does not know steps were lost, so the position error remains.

Q9. In which unit is stepper motor torque usually specified?

  • (a) Watts
  • (b) Newton-metres (N·m) or N·cm
  • (c) Revolutions per minute
  • (d) Ampere-turns

Answer: (b) Newton-metres (N·m) or N·cm — torque is a turning force, measured in newton-metres (small steppers often quote N·cm).

Q10. Which torque is larger in a hybrid stepper motor: holding torque or detent torque?

  • (a) Detent torque is larger
  • (b) Holding torque is much larger, because it is produced by the energised windings at rated current
  • (c) They are always exactly equal
  • (d) Neither exists in a hybrid motor

Answer: (b) Holding torque is much larger, because it is produced by the energised windings at rated current — detent torque comes only from the permanent magnet with no power, so it is only a small fraction of the holding torque.

Also read: DC Motor Calculator | All MCQ Topics