Solar Inverter MCQs — Set 7

10 practice questions on inverter safety — anti-islanding, earthing, isolators and protection devices, with answers and explanations.

Q1. What does anti-islanding protection do?

  • (a) It disconnects the inverter from the grid when the grid supply fails
  • (b) It keeps the inverter running during a blackout
  • (c) It increases the inverter’s output voltage
  • (d) It charges the battery from the grid

Answer: (a) It disconnects the inverter from the grid when the grid supply fails — the inverter must not keep a dead section of grid energised.

Q2. Why is anti-islanding protection required?

  • (a) To save electricity at night
  • (b) To make the panels produce more power
  • (c) To protect line workers from live wires they believe are dead
  • (d) To reduce the inverter’s cost

Answer: (c) To protect line workers from live wires they believe are dead — an inverter feeding a “dead” grid could electrocute someone repairing it.

Q3. Which standards cover anti-islanding and grid connection of inverters?

  • (a) IEC 60364 for wiring colours only
  • (b) IEEE 1547 and UL 1741
  • (c) ISO 9001 for office quality
  • (d) IP65 for water resistance only

Answer: (b) IEEE 1547 and UL 1741 — these are the recognised standards for inverter grid connection and anti-islanding behaviour.

Q4. What trip current is used for an RCCB that protects people against electric shock?

  • (a) 100 mA
  • (b) 300 mA
  • (c) 500 mA
  • (d) 30 mA

Answer: (d) 30 mA — a 30 mA RCCB trips fast enough on a small leakage current to protect a person from a dangerous shock.

Q5. A home uses 30 kWh of electricity per day and gets 5 peak sun hours. How many 400 W solar panels are needed?

  • (a) 10 panels
  • (b) 12 panels
  • (c) 15 panels
  • (d) 20 panels

Answer: (c) 15 panels — the array must be 30 ÷ 5 = 6 kW, and 6,000 ÷ 400 = 15 panels.

Q6. What is the purpose of the DC isolator switch between the panels and the inverter?

  • (a) It increases the panel voltage
  • (b) It lets the panels be safely disconnected from the inverter for maintenance
  • (c) It converts DC to AC
  • (d) It charges the battery faster

Answer: (b) It lets the panels be safely disconnected from the inverter for maintenance — the isolator breaks the DC supply so work can be done safely.

Q7. Why must a solar inverter and its metal casing be earthed (grounded)?

  • (a) To make the inverter lighter
  • (b) To increase its power output
  • (c) To give fault current a safe path to earth and trip the protection device
  • (d) To stop the panels getting hot

Answer: (c) To give fault current a safe path to earth and trip the protection device — earthing keeps the casing from becoming live during a fault.

Q8. What is the purpose of rapid shutdown in a rooftop solar system?

  • (a) To shut the panels down every night
  • (b) To increase the system’s voltage
  • (c) To disconnect the inverter from the battery
  • (d) To de-energise the roof conductors quickly so firefighters can work safely

Answer: (d) To de-energise the roof conductors quickly so firefighters can work safely — rapid shutdown drops the DC voltage on the roof to a safe level within seconds.

Q9. The inverter shows a “grid fault” or “grid out of range” message. What should be checked first?

  • (a) Whether the grid voltage and frequency are within the allowed range
  • (b) Whether the panels are dusty
  • (c) Whether the battery water level is low
  • (d) Whether the inverter’s paint is scratched

Answer: (a) Whether the grid voltage and frequency are within the allowed range — the inverter refuses to connect when the grid is outside its limits.

Q10. What does a surge protection device (SPD) on the inverter protect against?

  • (a) Shading on the panels
  • (b) Lightning strikes and transient voltage surges
  • (c) Low sunlight in winter
  • (d) Battery over-discharge

Answer: (b) Lightning strikes and transient voltage surges — the SPD diverts sudden high-voltage spikes away from the inverter’s electronics.