Single-Phase Motor MCQs — Set 2
10 practice questions on capacitor-start single-phase motors — the starting capacitor, the centrifugal switch and high starting torque — with answers and explanations.
Q1. What is the main job of the capacitor in a capacitor-start motor?
- (a) To store energy for running the motor after a power cut
- (b) To make the auxiliary-winding current lead the main-winding current by nearly 90°
- (c) To reduce the supply voltage to the main winding
- (d) To protect the motor from overload
Answer: (b) To make the auxiliary-winding current lead the main-winding current by nearly 90° — the large phase split produces a strong rotating field and high starting torque.
Q2. At about what fraction of full speed does the centrifugal switch of a capacitor-start motor open?
- (a) About 25% of full speed
- (b) About 50% of full speed
- (c) About 75% of full speed
- (d) About 100% of full speed
Answer: (c) About 75% of full speed — once the motor is up to roughly 75% of synchronous speed, the starting winding and capacitor are cut out.
Q3. Compared with a plain split-phase motor, a capacitor-start motor has what kind of starting torque?
- (a) Much lower starting torque
- (b) About the same starting torque
- (c) Much higher starting torque
- (d) Zero starting torque
Answer: (c) Much higher starting torque — the capacitor gives a near-90° phase split, so starting torque is typically 3 to 4 times full-load torque.
Q4. What happens if the starting capacitor of a capacitor-start motor is left permanently in circuit?
- (a) The motor runs more efficiently
- (b) The capacitor overheats and can fail, and the motor draws excess current
- (c) The motor reverses direction
- (d) Nothing changes at all
Answer: (b) The capacitor overheats and can fail, and the motor draws excess current — electrolytic starting capacitors are rated for short-duty starting only.
Q5. Which of these loads is a typical application for a capacitor-start motor?
- (a) A small table fan
- (b) A refrigerator compressor
- (c) A quartz wall clock
- (d) A shaver motor
Answer: (b) A refrigerator compressor — compressors need high starting torque to start against refrigerant pressure, which a capacitor-start motor provides.
Q6. In a capacitor-start motor, the starting capacitor is connected in series with which winding?
- (a) The main winding only
- (b) The auxiliary (starting) winding
- (c) The rotor winding
- (d) The shading coil
Answer: (b) The auxiliary (starting) winding — the capacitor and the centrifugal switch are in series with the starting winding, all in parallel with the main winding.
Q7. If the centrifugal switch of a capacitor-start motor sticks closed, what is the most likely result?
- (a) The motor will not start at all
- (b) The starting winding and capacitor stay in circuit, overheat and may burn out
- (c) The motor runs at double speed
- (d) The supply fuse blows instantly at switch-on
Answer: (b) The starting winding and capacitor stay in circuit, overheat and may burn out — the starting winding is not designed for continuous duty.
Q8. What is the synchronous speed of an 8-pole capacitor-start motor on a 50 Hz supply?
- (a) 3,000 rpm
- (b) 1,500 rpm
- (c) 1,000 rpm
- (d) 750 rpm
Answer: (d) 750 rpm — Ns = 120 × f ÷ P = 120 × 50 ÷ 8 = 750 rpm.
Q9. How can the direction of rotation of a capacitor-start motor be reversed?
- (a) By swapping the supply live and neutral wires
- (b) By reversing the connections of either the main winding or the auxiliary winding, but not both
- (c) By fitting a larger capacitor
- (d) By reversing the rotor end rings
Answer: (b) By reversing the connections of either the main winding or the auxiliary winding, but not both — this reverses the phase sequence of the rotating field.
Q10. A 4-pole capacitor-start motor runs at 1,470 rpm on a 50 Hz supply. What is its percentage slip?
- (a) 1%
- (b) 2%
- (c) 4%
- (d) 5%
Answer: (b) 2% — synchronous speed is 1,500 rpm, so slip = (1,500 − 1,470) ÷ 1,500 × 100 = 2%.
Also read: Washing Machine Motor Guide | All MCQ Topics