Servo Motor MCQs — Set 10

10 practice questions on servo motor faults and troubleshooting — with answers and explanations.

Q1. What is the most likely symptom of a failed encoder in a servo system?

  • (a) The motor runs faster than normal
  • (b) A position error alarm, erratic movement or a runaway motor
  • (c) The supply voltage increases
  • (d) The motor becomes completely silent

Answer: (b) A position error alarm, erratic movement or a runaway motor — without true position feedback the drive cannot control the motor safely.

Q2. What is the most common cause of a servo motor overheating?

  • (a) Running at too low a speed
  • (b) Continuous overload or holding high torque at standstill for too long
  • (c) Using a shielded encoder cable
  • (d) A clean, well-ventilated cabinet

Answer: (b) Continuous overload or holding high torque at standstill for too long — sustained high current heats the windings beyond their rating.

Q3. What does a “following error” alarm on a servo drive mean?

  • (a) The motor is following the command perfectly
  • (b) The actual position is lagging behind the commanded position by more than the allowed limit
  • (c) The encoder cable is disconnected
  • (d) The supply frequency is wrong

Answer: (b) The actual position is lagging behind the commanded position by more than the allowed limit — it usually means the load is too heavy, the motor is stalled, or the gains are too low.

Q4. What is a common cause of vibration in a servo-driven machine?

  • (a) Gains set too high or a mechanical resonance in the load
  • (b) A motor that is too large for the load
  • (c) A perfectly tuned loop
  • (d) A short encoder cable

Answer: (a) Gains set too high or a mechanical resonance in the load — both make the loop oscillate, and a notch filter or lower gains usually cure it.

Q5. What is a likely cause of an overcurrent trip on a servo drive?

  • (a) A shorted motor winding or a mechanically jammed load
  • (b) The motor running with no load
  • (c) The encoder resolution being too high
  • (d) The ambient temperature being too low

Answer: (a) A shorted motor winding or a mechanically jammed load — both force the drive to push excessive current into the motor.

Q6. Why must the encoder cable be shielded and kept away from motor power cables?

  • (a) To make the cable look neat
  • (b) To stop electrical noise from creating false position counts
  • (c) To increase the motor’s torque
  • (d) To reduce the cable’s weight

Answer: (b) To stop electrical noise from creating false position counts — switching noise from the power cables can corrupt the small encoder signals.

Q7. A servo motor runs but the load does not move. What should be checked first?

  • (a) The supply frequency
  • (b) The coupling between the motor shaft and the load
  • (c) The colour of the motor
  • (d) The room temperature

Answer: (b) The coupling between the motor shaft and the load — a broken or slipping coupling lets the motor spin freely while the load stays still.

Q8. What problem can regenerative energy cause in a servo drive during fast deceleration?

  • (a) The DC bus voltage rises and can trip the drive on overvoltage
  • (b) The motor speeds up on its own
  • (c) The encoder stops working
  • (d) The supply current drops to zero

Answer: (a) The DC bus voltage rises and can trip the drive on overvoltage — the motor acts as a generator while braking, and the energy must be absorbed by a braking resistor or returned to the supply.

Q9. What effect does backlash in a gearbox or coupling have on a servo system?

  • (a) It improves positioning accuracy
  • (b) It causes lost motion when the direction reverses, hurting accuracy
  • (c) It increases the motor’s torque
  • (d) It has no effect at all

Answer: (b) It causes lost motion when the direction reverses, hurting accuracy — the motor must turn through the backlash gap before the load starts moving.

Q10. A servo motor will not move at all. What is the first thing to check?

  • (a) Whether the drive is enabled, a command is present and no alarm is active
  • (b) Whether the motor needs repainting
  • (c) Whether the gearbox oil is fresh
  • (d) Whether the encoder resolution is high enough

Answer: (a) Whether the drive is enabled, a command is present and no alarm is active — most “dead servo” faults are a missing enable signal, no command, or an uncleared alarm.

Also read: DC Motor Calculator | All MCQ Topics