Sensor MCQs — Set 8
10 practice questions on sensor wiring and selection — wire colours, NPN and PNP outputs, NO/NC contacts, IP ratings and noise protection.
Q1. In a standard 3-wire DC proximity sensor, what is each wire for?
- (a) Brown = +24 V, blue = 0 V, black = output signal
- (b) Brown = output, blue = +24 V, black = 0 V
- (c) All three wires carry the output signal
- (d) Brown = earth, blue = output, black = +24 V
Answer: (a) Brown = +24 V, blue = 0 V, black = output signal — this is the standard industrial colour code for 3-wire DC sensors.
Q2. A PNP sensor output is connected to a load. When the sensor detects a target, what happens?
- (a) The output connects the load to 0 V
- (b) The output supplies +24 V to the load (it sources current)
- (c) The output disconnects the power supply
- (d) Nothing — PNP sensors have no output
Answer: (b) The output supplies +24 V to the load (it sources current) — the load is wired between the black output wire and 0 V, so it turns on when the sensor switches.
Q3. An NPN sensor output is connected to a load. When the sensor detects a target, what happens?
- (a) The output supplies +24 V to the load
- (b) The output connects the load to 0 V (it sinks current from the load)
- (c) The output reverses the supply polarity
- (d) The sensor stops working
Answer: (b) The output connects the load to 0 V (it sinks current from the load) — the load is wired between +24 V and the black output wire, so current flows through the load into the sensor when it switches.
Q4. What is the difference between a normally open (NO) and a normally closed (NC) sensor contact?
- (a) NO is open with no target and closes on detection; NC is closed with no target and opens on detection
- (b) NO works on AC and NC works on DC
- (c) NO is always on and NC is always off
- (d) There is no difference
Answer: (a) NO is open with no target and closes on detection; NC is closed with no target and opens on detection — NC contacts are often used for safety, so a broken wire fails safe by opening the circuit.
Q5. What does an IP65 rating mean for a sensor?
- (a) It can be submerged in water indefinitely
- (b) It is dust-tight and protected against water jets from any direction
- (c) It is protected only against dust, not water
- (d) It can be used in explosive atmospheres
Answer: (b) It is dust-tight and protected against water jets from any direction — the first digit 6 means dust-tight and the second digit 5 means protected against low-pressure water jets.
Q6. What does an IP67 rating mean for a sensor?
- (a) It is dust-tight and can be immersed in water up to 1 m deep for 30 minutes
- (b) It is dust-tight but must never get wet
- (c) It is waterproof at any depth
- (d) It is protected against water jets only
Answer: (a) It is dust-tight and can be immersed in water up to 1 m deep for 30 minutes — IP67 suits washdown areas and outdoor use, while IP65 covers jets but not immersion.
Q7. Why is shielded cable used for sensor signals?
- (a) To make the cable stronger
- (b) To reduce electrical noise and interference picked up from nearby power cables and motors
- (c) To increase the sensor’s sensing distance
- (d) To allow higher supply voltage
Answer: (b) To reduce electrical noise and interference picked up from nearby power cables and motors — the earthed shield blocks electromagnetic interference that would otherwise corrupt the small sensor signal.
Q8. What supply voltage is most commonly used for industrial sensors?
- (a) 230 V AC
- (b) 24 V DC
- (c) 5 V AC
- (d) 110 V DC
Answer: (b) 24 V DC — it is the standard control voltage in panels and machines, safe to work with and directly compatible with PLCs.
Q9. How is a 2-wire sensor connected?
- (a) In parallel with the load
- (b) In series with the load, in the same loop as the power supply
- (c) Directly across the power supply with no load
- (d) It needs four wires to work
Answer: (b) In series with the load, in the same loop as the power supply — the sensor and load share one current path, like a switch, and the sensor is powered by the small voltage drop across itself.
Q10. A sensor must detect a steel part passing 10 mm away. Which rating must you check first when choosing the sensor?
- (a) The sensor’s rated sensing distance, which must be greater than 10 mm for that target material
- (b) The colour of the sensor housing
- (c) The length of the sensor cable
- (d) The weight of the sensor
Answer: (a) The sensor’s rated sensing distance, which must be greater than 10 mm for that target material — rated distance is given for mild steel, so a sensor rated at 8 mm would never see the part, and a margin above the working gap is needed.
Also read: DC Motor MCQs | All MCQ Topics