Sensor MCQs — Set 8

10 practice questions on sensor wiring and selection — wire colours, NPN and PNP outputs, NO/NC contacts, IP ratings and noise protection.

Q1. In a standard 3-wire DC proximity sensor, what is each wire for?

  • (a) Brown = +24 V, blue = 0 V, black = output signal
  • (b) Brown = output, blue = +24 V, black = 0 V
  • (c) All three wires carry the output signal
  • (d) Brown = earth, blue = output, black = +24 V

Answer: (a) Brown = +24 V, blue = 0 V, black = output signal — this is the standard industrial colour code for 3-wire DC sensors.

Q2. A PNP sensor output is connected to a load. When the sensor detects a target, what happens?

  • (a) The output connects the load to 0 V
  • (b) The output supplies +24 V to the load (it sources current)
  • (c) The output disconnects the power supply
  • (d) Nothing — PNP sensors have no output

Answer: (b) The output supplies +24 V to the load (it sources current) — the load is wired between the black output wire and 0 V, so it turns on when the sensor switches.

Q3. An NPN sensor output is connected to a load. When the sensor detects a target, what happens?

  • (a) The output supplies +24 V to the load
  • (b) The output connects the load to 0 V (it sinks current from the load)
  • (c) The output reverses the supply polarity
  • (d) The sensor stops working

Answer: (b) The output connects the load to 0 V (it sinks current from the load) — the load is wired between +24 V and the black output wire, so current flows through the load into the sensor when it switches.

Q4. What is the difference between a normally open (NO) and a normally closed (NC) sensor contact?

  • (a) NO is open with no target and closes on detection; NC is closed with no target and opens on detection
  • (b) NO works on AC and NC works on DC
  • (c) NO is always on and NC is always off
  • (d) There is no difference

Answer: (a) NO is open with no target and closes on detection; NC is closed with no target and opens on detection — NC contacts are often used for safety, so a broken wire fails safe by opening the circuit.

Q5. What does an IP65 rating mean for a sensor?

  • (a) It can be submerged in water indefinitely
  • (b) It is dust-tight and protected against water jets from any direction
  • (c) It is protected only against dust, not water
  • (d) It can be used in explosive atmospheres

Answer: (b) It is dust-tight and protected against water jets from any direction — the first digit 6 means dust-tight and the second digit 5 means protected against low-pressure water jets.

Q6. What does an IP67 rating mean for a sensor?

  • (a) It is dust-tight and can be immersed in water up to 1 m deep for 30 minutes
  • (b) It is dust-tight but must never get wet
  • (c) It is waterproof at any depth
  • (d) It is protected against water jets only

Answer: (a) It is dust-tight and can be immersed in water up to 1 m deep for 30 minutes — IP67 suits washdown areas and outdoor use, while IP65 covers jets but not immersion.

Q7. Why is shielded cable used for sensor signals?

  • (a) To make the cable stronger
  • (b) To reduce electrical noise and interference picked up from nearby power cables and motors
  • (c) To increase the sensor’s sensing distance
  • (d) To allow higher supply voltage

Answer: (b) To reduce electrical noise and interference picked up from nearby power cables and motors — the earthed shield blocks electromagnetic interference that would otherwise corrupt the small sensor signal.

Q8. What supply voltage is most commonly used for industrial sensors?

  • (a) 230 V AC
  • (b) 24 V DC
  • (c) 5 V AC
  • (d) 110 V DC

Answer: (b) 24 V DC — it is the standard control voltage in panels and machines, safe to work with and directly compatible with PLCs.

Q9. How is a 2-wire sensor connected?

  • (a) In parallel with the load
  • (b) In series with the load, in the same loop as the power supply
  • (c) Directly across the power supply with no load
  • (d) It needs four wires to work

Answer: (b) In series with the load, in the same loop as the power supply — the sensor and load share one current path, like a switch, and the sensor is powered by the small voltage drop across itself.

Q10. A sensor must detect a steel part passing 10 mm away. Which rating must you check first when choosing the sensor?

  • (a) The sensor’s rated sensing distance, which must be greater than 10 mm for that target material
  • (b) The colour of the sensor housing
  • (c) The length of the sensor cable
  • (d) The weight of the sensor

Answer: (a) The sensor’s rated sensing distance, which must be greater than 10 mm for that target material — rated distance is given for mild steel, so a sensor rated at 8 mm would never see the part, and a margin above the working gap is needed.

Also read: DC Motor MCQs | All MCQ Topics