Sensor MCQs — Set 5
10 practice questions on current and voltage sensing — current transformers, Hall current sensors, shunts and voltage dividers.
Q1. A current transformer is rated 100/5 A. If the primary current is 20 A, what is the secondary current?
- (a) 5 A
- (b) 1 A
- (c) 0.5 A
- (d) 20 A
Answer: (b) 1 A — the ratio is 100 ÷ 5 = 20, so secondary current = 20 ÷ 20 = 1 A.
Q2. A current transformer is rated 200/5 A. If the primary current is 40 A, what is the secondary current?
- (a) 5 A
- (b) 2 A
- (c) 1 A
- (d) 8 A
Answer: (c) 1 A — the ratio is 200 ÷ 5 = 40, so secondary current = 40 ÷ 40 = 1 A.
Q3. A current transformer is rated 400/5 A and the primary carries 200 A. What is the secondary current?
- (a) 5 A
- (b) 2.5 A
- (c) 1 A
- (d) 40 A
Answer: (b) 2.5 A — the ratio is 400 ÷ 5 = 80, so secondary current = 200 ÷ 80 = 2.5 A.
Q4. Why must the secondary of a current transformer never be left open-circuited while current flows in the primary?
- (a) The primary will overheat and melt
- (b) A dangerously high voltage is induced in the open secondary
- (c) The meter will read zero permanently
- (d) The primary current will stop flowing
Answer: (b) A dangerously high voltage is induced in the open secondary — with no load the secondary tries to drive the full flux, producing thousands of volts that can kill and damage insulation, so an unused CT secondary must always be shorted.
Q5. What is the advantage of a Hall effect current sensor over a standard current transformer?
- (a) It can measure DC as well as AC without breaking the circuit
- (b) It needs no magnetic core
- (c) It can only measure very small currents
- (d) It works without any power supply
Answer: (a) It can measure DC as well as AC without breaking the circuit — a standard CT works on changing flux only, so it cannot measure DC, while a Hall sensor reads the steady magnetic field of a DC conductor too.
Q6. A 100 A current flows through a 1 mΩ shunt resistor. What voltage appears across the shunt?
- (a) 1 V
- (b) 100 mV
- (c) 10 mV
- (d) 10 V
Answer: (b) 100 mV — V = I × R = 100 × 0.001 = 0.1 V = 100 mV.
Q7. A 50 A current flows through a 2 mΩ shunt resistor. What voltage appears across the shunt?
- (a) 100 mV
- (b) 25 mV
- (c) 1 V
- (d) 10 mV
Answer: (a) 100 mV — V = I × R = 50 × 0.002 = 0.1 V = 100 mV.
Q8. A voltage divider uses a 9 kΩ resistor in series with a 1 kΩ resistor across a 24 V supply. What is the voltage across the 1 kΩ resistor?
- (a) 24 V
- (b) 21.6 V
- (c) 2.4 V
- (d) 12 V
Answer: (c) 2.4 V — Vout = 24 × 1 ÷ (9 + 1) = 24 ÷ 10 = 2.4 V. This is how a high voltage is scaled down for a microcontroller ADC input.
Q9. A voltage divider uses a 3 kΩ resistor in series with a 1 kΩ resistor across a 12 V supply. What is the voltage across the 1 kΩ resistor?
- (a) 9 V
- (b) 3 V
- (c) 12 V
- (d) 4 V
Answer: (b) 3 V — Vout = 12 × 1 ÷ (3 + 1) = 12 ÷ 4 = 3 V.
Q10. Can a standard current transformer measure DC current?
- (a) Yes, it measures DC and AC equally well
- (b) No, it works only on AC because it needs a changing magnetic flux
- (c) Yes, but only below 5 A
- (d) No, because DC would melt its core
Answer: (b) No, it works only on AC because it needs a changing magnetic flux — a steady DC produces no changing flux, so nothing is induced in the secondary; a Hall sensor or shunt is used for DC.