Safety PPE MCQs — Set 7

10 practice questions on test-before-touch — proving testers, the live-dead-live check and proving a circuit is dead.

Q1. What does test-before-touch mean?

  • (a) Touch the conductor first, then test it
  • (b) Test the circuit with a suitable instrument to prove it is dead before touching any conductor
  • (c) Test the circuit only after the work is finished
  • (d) Touch the tester to the wall before use

Answer: (b) Test the circuit with a suitable instrument to prove it is dead before touching any conductor — never assume a circuit is dead because a switch is off.

Q2. What is the correct live-dead-live test sequence?

  • (a) Test the dead circuit, then test a known live source
  • (b) Test the tester on a known live source, test the circuit to be worked on, then re-test the tester on the known live source
  • (c) Test the circuit twice and skip the live source
  • (d) Test the tester once a week only

Answer: (b) Test the tester on a known live source, test the circuit to be worked on, then re-test the tester on the known live source — this proves the tester was working both before and after the dead test.

Q3. What is a proving unit used for?

  • (a) To charge the tester’s batteries
  • (b) To provide a known voltage source to check that a voltage tester is working
  • (c) To measure insulation resistance
  • (d) To discharge capacitors

Answer: (b) To provide a known voltage source to check that a voltage tester is working — if no live source is available, the proving unit is the known source for the live-dead-live check.

Q4. What is a key limitation of a non-contact voltage tester (voltage pen)?

  • (a) It is too accurate
  • (b) It can give a false negative, so it must not be the only test used to prove a circuit dead
  • (c) It cannot detect any voltage at all
  • (d) It only works on DC circuits

Answer: (b) It can give a false negative, so it must not be the only test used to prove a circuit dead — a contact two-pole tester should confirm the dead test.

Q5. What must a test instrument be rated for before it is used?

  • (a) Only the colour of the leads
  • (b) The voltage and category (CAT rating) of the circuit being tested
  • (c) The brand of the instrument
  • (d) The age of the instrument

Answer: (b) The voltage and category (CAT rating) of the circuit being tested — an under-rated tester can fail dangerously on a higher-energy circuit.

Q6. Why should insulated gloves be worn while testing for absence of voltage?

  • (a) To keep the hands clean
  • (b) Because the circuit may still be live, and the gloves protect against shock during the test
  • (c) Gloves make the tester more accurate
  • (d) Gloves are only needed in cold weather

Answer: (b) Because the circuit may still be live, and the gloves protect against shock during the test — until the circuit is proven dead, it must be treated as live.

Q7. What should a worker do if the tester shows voltage on a circuit that was supposed to be isolated?

  • (a) Ignore the reading and start work
  • (b) Treat the circuit as live, stop work and find out why it is still energised
  • (c) Test again with bare hands
  • (d) Remove the tester batteries

Answer: (b) Treat the circuit as live, stop work and find out why it is still energised — the isolation may be on the wrong circuit or a second supply may be present.

Q8. When proving a three-phase circuit dead, what must be tested?

  • (a) Only one phase
  • (b) Each phase to earth and each phase to each other phase
  • (c) Only the neutral
  • (d) Only the earth conductor

Answer: (b) Each phase to earth and each phase to each other phase — testing only one phase could miss another phase that is still live.

Q9. Why is a purpose-built two-pole voltage tester preferred over a general multimeter for proving dead?

  • (a) It is cheaper
  • (b) It is designed for the job, with no range switch to set wrongly and clear voltage indication
  • (c) It measures resistance as well
  • (d) It has a longer battery life

Answer: (b) It is designed for the job, with no range switch to set wrongly and clear voltage indication — a multimeter on the wrong range can show zero on a live circuit.

Q10. What does the final re-test on the known live source prove?

  • (a) That the circuit is live
  • (b) That the tester did not fail during the dead test, so the “dead” reading can be trusted
  • (c) That the batteries are new
  • (d) That the proving unit is working

Answer: (b) That the tester did not fail during the dead test, so the “dead” reading can be trusted — a tester that fails silently could show zero on a live circuit.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics