Q1. What is the purpose of the spring in an electromagnetic relay?

  • (a) To increase the coil current
  • (b) To return the armature and contacts to their normal position when the coil is de-energised
  • (c) To cool the contacts
  • (d) To step down the voltage

Answer: (b) To return the armature and contacts to their normal position when the coil is de-energised — without the spring the contacts would stay in the operated position.

Q2. What is a latching relay?

  • (a) A relay that trips only on short circuits
  • (b) A relay that stays in its last switched position after the coil supply is removed, until a reset pulse is applied
  • (c) A relay with no contacts at all
  • (d) A relay that can only switch DC loads

Answer: (b) A relay that stays in its last switched position after the coil supply is removed, until a reset pulse is applied — it needs power only for the moment of switching.

Q3. A relay contact is rated 10 A at 250 V AC. What does this rating mean?

  • (a) The coil needs 10 A at 250 V
  • (b) It is the maximum current and voltage the contact can safely switch
  • (c) It will trip at exactly 10 A
  • (d) It can only be used on 10 A circuits at any voltage

Answer: (b) It is the maximum current and voltage the contact can safely switch — exceeding either rating can weld or burn the contacts.

Q4. Why is a flyback (freewheeling) diode connected across a DC relay coil?

  • (a) To increase the coil voltage
  • (b) To suppress the high voltage spike produced when the coil is switched off
  • (c) To make the relay latch
  • (d) To reduce the coil resistance

Answer: (b) To suppress the high voltage spike produced when the coil is switched off — the collapsing magnetic field would otherwise drive a large reverse voltage into the driving circuit.

Q5. What is contact bounce in a relay?

  • (a) The contact welding shut permanently
  • (b) The contacts making and breaking rapidly several times as they close
  • (c) The coil vibrating at supply frequency
  • (d) The relay switching on and off once a day

Answer: (b) The contacts making and breaking rapidly several times as they close — the moving contact rebounds off the fixed contact before settling.

Q6. A 24 V relay coil has a resistance of 600 Ω. What current does it draw when energised?

  • (a) 40 mA
  • (b) 400 mA
  • (c) 4 A
  • (d) 14.4 A

Answer: (a) 40 mA — I = V ÷ R = 24 ÷ 600 = 0.04 A = 40 mA.

Q7. What is the main difference between a relay and a contactor?

  • (a) A contactor has no coil
  • (b) A contactor is a heavy-duty relay built to switch large currents, often for three-phase motors
  • (c) A relay can only switch AC and a contactor only DC
  • (d) A contactor works without any control signal

Answer: (b) A contactor is a heavy-duty relay built to switch large currents, often for three-phase motors — the working principle is the same, the construction is heavier.

Q8. What does the pickup voltage of a relay mean?

  • (a) The voltage at which the contacts melt
  • (b) The minimum coil voltage that reliably closes the contacts
  • (c) The maximum voltage the contacts can switch
  • (d) The supply voltage of the load circuit

Answer: (b) The minimum coil voltage that reliably closes the contacts — below this voltage the armature may not pull in fully.

Q9. Why are relay contacts often made of silver alloy?

  • (a) Silver is the cheapest metal available
  • (b) Silver alloy has low contact resistance and resists damage from arcing
  • (c) Silver makes the relay magnetic
  • (d) Silver increases the coil current

Answer: (b) Silver alloy has low contact resistance and resists damage from arcing — it keeps the contact drop small and prevents the contacts welding together.

Q10. A relay has a coil rated 5 V with a resistance of 125 Ω. What current flows through the coil when it is energised?

  • (a) 40 mA
  • (b) 625 mA
  • (c) 25 mA
  • (d) 0.4 A

Answer: (a) 40 mA — I = V ÷ R = 5 ÷ 125 = 0.04 A = 40 mA.