Relay MCQs — Set 1
10 practice questions on what a relay is and how an electromagnetic relay works — coils, armature and contacts. Work each one out before checking the answer.
Q1. What is the main function of a relay in an electrical circuit?
- (a) To step voltage up or down
- (b) To switch a high-power circuit using a low-power control signal
- (c) To store electrical charge
- (d) To convert AC to DC
Answer: (b) To switch a high-power circuit using a low-power control signal — a small current in the coil switches a much larger load current through the contacts.
Q2. Which part of an electromagnetic relay creates the magnetic field that moves the armature?
- (a) The contact spring
- (b) The coil
- (c) The terminal block
- (d) The enclosure
Answer: (b) The coil — current through the coil produces the magnetic field that pulls the armature.
Q3. A relay coil is rated 12 V and has a resistance of 400 Ω. What current does it draw when energised?
- (a) 30 mA
- (b) 300 mA
- (c) 3 A
- (d) 4.8 A
Answer: (a) 30 mA — I = V ÷ R = 12 ÷ 400 = 0.03 A = 30 mA.
Q4. What does NO stand for on a relay contact?
- (a) Normally Open
- (b) No Output
- (c) Neutral Only
- (d) Normally Overloaded
Answer: (a) Normally Open — the contact is open when the coil is de-energised and closes when the coil is energised.
Q5. When a relay coil is de-energised, what happens to a normally closed (NC) contact?
- (a) It stays open
- (b) It melts
- (c) It returns to the closed position
- (d) It reverses polarity
Answer: (c) It returns to the closed position — NC contacts are closed at rest and open only while the coil is energised.
Q6. Why is a relay used instead of wiring a manual switch directly into a high-current circuit?
- (a) A relay is cheaper than any switch
- (b) The relay keeps the operator and the low-power control circuit isolated from the high-power circuit
- (c) A relay increases the supply voltage
- (d) A relay removes the need for a fuse
Answer: (b) The relay keeps the operator and the low-power control circuit isolated from the high-power circuit — the control side never carries the load current.
Q7. What is the armature in an electromagnetic relay?
- (a) The fixed terminal that holds the wiring
- (b) The moving iron part that is pulled by the magnetic field to operate the contacts
- (c) The plastic cover of the relay
- (d) The diode across the coil
Answer: (b) The moving iron part that is pulled by the magnetic field to operate the contacts — its movement opens or closes the contacts.
Q8. A relay switches a 230 V motor from a 24 V control circuit. What is this an example of?
- (a) Voltage transformation
- (b) Low-voltage control of a high-voltage load with isolation between the two circuits
- (c) Power factor correction
- (d) Frequency conversion
Answer: (b) Low-voltage control of a high-voltage load with isolation between the two circuits — the 24 V side only energises the coil.
Q9. What happens to the contacts of a relay when its coil is energised?
- (a) NO contacts close and NC contacts open
- (b) NO contacts open and NC contacts close
- (c) All contacts open
- (d) All contacts stay as they were
Answer: (a) NO contacts close and NC contacts open — the armature moves and changes the state of every contact.
Q10. Which of these is NOT a part of a standard electromagnetic relay?
- (a) Coil
- (b) Armature
- (c) Spring
- (d) Bimetallic strip
Answer: (d) Bimetallic strip — a bimetallic strip belongs to a thermal overload relay, not to an electromagnetic relay.