Pump MCQs — Set 8
10 practice questions on pump installation and piping — suction lift, foot valves, strainers and pipe sizing — with answers and explanations.
Q1. How should a suction pipe be laid between the water source and the pump?
- (a) As long as possible, with several high points
- (b) As short as possible, sloping steadily upward toward the pump with no air pockets
- (c) Sloping downward toward the pump
- (d) With a loop above the pump level
Answer: (b) As short as possible, sloping steadily upward toward the pump with no air pockets — a short, rising suction line keeps friction low and prevents air collecting in high spots, which would break the prime.
Q2. Where is the foot valve fitted in a suction line?
- (a) At the pump outlet
- (b) At the bottom end of the suction pipe, inside the water
- (c) At the top of the overhead tank
- (d) In the middle of the delivery pipe
Answer: (b) At the bottom end of the suction pipe, inside the water — it holds the suction line full of water when the pump stops, so the pump stays primed.
Q3. What is the theoretical maximum suction lift of a pump at sea level?
- (a) About 1 m
- (b) About 5 m
- (c) About 10 m
- (d) About 30 m
Answer: (c) About 10 m — atmospheric pressure can support only about 10.3 m of water column, so no surface pump can lift water higher by suction alone; in practice the limit is about 7–8 m.
Q4. What happens if the suction pipe diameter is smaller than the pump inlet?
- (a) Flow increases
- (b) Friction losses rise and cavitation risk increases
- (c) The pump primes faster
- (d) Nothing changes
Answer: (b) Friction losses rise and cavitation risk increases — a narrow suction pipe raises water velocity and friction, dropping inlet pressure and inviting cavitation.
Q5. Where should a non-return valve be fitted in a pump installation?
- (a) On the suction side only
- (b) On the delivery side, to stop water flowing back when the pump stops
- (c) Inside the motor terminal box
- (d) At the bottom of the well
Answer: (b) On the delivery side, to stop water flowing back when the pump stops — it prevents the pumped water from returning and spinning the impeller backwards.
Q6. What is the priming plug on a centrifugal pump casing used for?
- (a) To drain oil from the motor
- (b) To pour water into the casing to prime the pump before starting
- (c) To measure the motor current
- (d) To connect the delivery pipe
Answer: (b) To pour water into the casing to prime the pump before starting — water is filled through the plug until the casing and suction pipe are full and air-free.
Q7. Why should a pump be installed on a firm, level base close to the water source?
- (a) To make the paint last longer
- (b) To keep the suction lift short and reduce vibration
- (c) To increase the delivery head
- (d) To avoid earthing the motor
Answer: (b) To keep the suction lift short and reduce vibration — a short suction line primes easily and cavitates less, and a firm base stops vibration and misalignment.
Q8. What is the purpose of a suction strainer at the end of the suction pipe?
- (a) To increase the flow rate
- (b) To stop sand, leaves and debris entering and damaging the pump
- (c) To measure the suction head
- (d) To hold the prime in the pump
Answer: (b) To stop sand, leaves and debris entering and damaging the pump — debris can jam or wear the impeller, so the strainer is fitted at the suction inlet and cleaned regularly.
Q9. Why is a gate valve fitted on the delivery side of a pump?
- (a) To prime the pump
- (b) To control the flow rate and isolate the pump for maintenance
- (c) To cool the motor
- (d) To increase the suction lift
Answer: (b) To control the flow rate and isolate the pump for maintenance — the valve throttles delivery flow and can be closed to work on the pump without draining the system.
Q10. What problem does an air pocket trapped in a high spot of the suction pipe cause?
- (a) The pump runs faster
- (b) Loss of prime and reduced or no flow
- (c) The motor draws less current
- (d) The delivery pressure rises
Answer: (b) Loss of prime and reduced or no flow — trapped air breaks the continuous water column, so the pump cannot lift water until the air is removed.
Also read: GFCI Outlet Keeps Tripping | All MCQ Topics