Pump MCQs — Set 7
10 practice questions on common pump faults — no water, low pressure, tripping, overheating, noise and leaks — with answers and explanations.
Q1. A pump motor runs but no water comes out of the delivery pipe. What should be checked first?
- (a) The motor capacitor
- (b) Whether the pump has lost its prime, the foot valve has failed, or the suction line has an air leak
- (c) The colour of the pump paint
- (d) The size of the overhead tank
Answer: (b) Whether the pump has lost its prime, the foot valve has failed, or the suction line has an air leak — a running centrifugal pump moves no water if air is in the casing or suction pipe instead of water.
Q2. A pump delivers water but at much lower pressure than before. What is a likely cause?
- (a) A worn impeller, a clogged suction strainer, or low supply voltage
- (b) A new foot valve
- (c) A larger delivery pipe
- (d) A full overhead tank
Answer: (a) A worn impeller, a clogged suction strainer, or low supply voltage — a worn impeller builds less head, a blocked strainer starves the pump, and low voltage slows the motor.
Q3. A pump trips the MCB immediately when it is switched on. What is the most likely cause?
- (a) The tank is full
- (b) A short circuit in the motor winding, a seized motor, or a failed capacitor causing a locked rotor
- (c) The foot valve is working normally
- (d) The delivery valve is partly open
Answer: (b) A short circuit in the motor winding, a seized motor, or a failed capacitor causing a locked rotor — an instant trip means a very high fault current, not a normal starting current.
Q4. A pump motor overheats after running for a short time. Which cause is most likely?
- (a) Running dry, blocked motor ventilation, or sustained overload
- (b) A full overhead tank
- (c) Cold weather
- (d) A new impeller
Answer: (a) Running dry, blocked motor ventilation, or sustained overload — dry running removes the water cooling, blocked vents trap heat, and overload draws excess current.
Q5. A pump has suddenly become very noisy and vibrates heavily. What should be suspected?
- (a) Cavitation, worn bearings, or loose mounting bolts
- (b) A clean suction strainer
- (c) Correct impeller rotation
- (d) A fully primed pump
Answer: (a) Cavitation, worn bearings, or loose mounting bolts — cavitation rattles the impeller, worn bearings rumble and vibrate, and loose bolts let the whole pump shake.
Q6. An automatic pump starts and stops every minute even though no tap is open. What is the most likely cause?
- (a) A waterlogged pressure tank or a pressure switch set with too narrow a cut-in/cut-out gap
- (b) A new non-return valve
- (c) A larger overhead tank
- (d) A clean impeller
Answer: (a) A waterlogged pressure tank or a pressure switch set with too narrow a cut-in/cut-out gap — with no air cushion in the tank, pressure falls the moment the pump stops, so it restarts immediately.
Q7. Water is leaking from the pump where the shaft enters the casing. Which part has failed?
- (a) The impeller
- (b) The mechanical seal
- (c) The capacitor
- (d) The foot valve
Answer: (b) The mechanical seal — the seal around the rotating shaft keeps water inside the casing; when it wears, water leaks out along the shaft and the seal must be replaced.
Q8. A pump delivers noticeably less water than its rated flow, although the motor speed is normal. What is the likely cause?
- (a) Impeller wear or a partial blockage in the suction or delivery pipe
- (b) A new motor bearing
- (c) A shorter suction pipe
- (d) A higher supply voltage
Answer: (a) Impeller wear or a partial blockage in the suction or delivery pipe — a worn impeller cannot build full head, and a blockage throttles the flow, even at normal speed.
Q9. A pump motor hums loudly but the shaft does not turn. What is the most likely cause?
- (a) The delivery valve is closed
- (b) A failed starting capacitor or a seized bearing locking the rotor
- (c) The overhead tank is empty
- (d) The suction pipe is too short
Answer: (b) A failed starting capacitor or a seized bearing locking the rotor — without starting torque, or with the rotor jammed, the motor hums on the spot; it must be switched off quickly before the winding burns.
Q10. A pump runs fine for 20 minutes, then the overload relay trips. After cooling it runs again and trips again. What is the likely cause?
- (a) Low supply voltage causing high current, or stiff bearings adding friction load
- (b) A full water tank
- (c) A clean suction strainer
- (d) A new capacitor
Answer: (a) Low supply voltage causing high current, or stiff bearings adding friction load — the motor draws extra current to deliver the same power, heating the overload until it trips; cooling resets it and the cycle repeats.