Power Factor Correction MCQs — Set 2
10 practice questions on lagging and leading power factor — which loads drag power factor down and why.
Q1. Which load is the most common cause of a lagging power factor in a factory?
- (a) Resistive heater
- (b) Induction motor
- (c) Incandescent lamp
- (d) LED lamp with a good driver
Answer: (b) Induction motor — induction motors draw magnetising current that lags the voltage, so they are the main cause of lagging power factor in industry.
Q2. A capacitor connected across a load draws a current that does what relative to the voltage?
- (a) Lags the voltage by 90°
- (b) Leads the voltage by 90°
- (c) Is in phase with the voltage
- (d) Lags the voltage by 180°
Answer: (b) Leads the voltage by 90° — capacitor current leads voltage, which is why capacitors cancel the lagging current of inductive loads.
Q3. Which of these loads runs at practically unity power factor?
- (a) Induction motor at full load
- (b) Arc welding set
- (c) Electric iron (resistive heating element)
- (d) Unloaded transformer
Answer: (c) Electric iron — a purely resistive load draws current in phase with voltage, so its power factor is close to 1.0.
Q4. A transformer running with no load has a very low power factor because:
- (a) It draws mainly magnetising current, which is almost purely reactive
- (b) It draws a large resistive current
- (c) Its windings are short-circuited
- (d) It delivers full-load power
Answer: (a) It draws mainly magnetising current, which is almost purely reactive — at no load the real power is tiny but the magnetising kVAR remains, so pf is very low.
Q5. In a lagging power factor load, the current:
- (a) Leads the voltage
- (b) Lags behind the voltage
- (c) Is in phase with the voltage
- (d) Is zero
Answer: (b) Lags behind the voltage — “lagging” means the current waveform reaches its peak after the voltage waveform.
Q6. Which equipment is well known for operating at a low lagging power factor?
- (a) Electric kettle
- (b) Arc welding transformer
- (c) Toaster
- (d) Incandescent bulb
Answer: (b) Arc welding transformer — welding sets use a highly inductive transformer and draw a large lagging current, so their power factor is poor.
Q7. A fluorescent lamp fitted with a magnetic choke has what kind of power factor?
- (a) Unity
- (b) Leading
- (c) Lagging, because the choke is inductive
- (d) Zero
Answer: (c) Lagging, because the choke is inductive — the ballast choke adds inductance, so the lamp current lags the voltage.
Q8. What happens to the power factor of an induction motor when it runs lightly loaded?
- (a) It improves toward unity
- (b) It falls, because the magnetising current stays almost the same while the useful current drops
- (c) It becomes leading
- (d) It stays exactly the same
Answer: (b) It falls, because the magnetising current stays almost the same while the useful current drops — lightly loaded motors are a classic cause of poor power factor.
Q9. Which device, when added to a circuit, makes the overall power factor leading?
- (a) An inductor
- (b) A resistor
- (c) A capacitor
- (d) A transformer
Answer: (c) A capacitor — capacitors supply leading reactive current, so enough capacitance turns a lagging power factor into a leading one.
Q10. Power factor is not a meaningful term for which type of supply?
- (a) Single-phase AC
- (b) Three-phase AC
- (c) Pure DC, because voltage and current do not alternate
- (d) 400 V AC
Answer: (c) Pure DC, because voltage and current do not alternate — power factor is cos φ, the phase angle in an AC circuit, and there is no phase angle in DC.
Also read: Watt Calculator | All MCQ Topics