NEC Code MCQs — Set 8

10 practice questions on NEC GFCI and AFCI protection — where each is required, what it trips on, and how they differ.

Q1. At what ground-fault current level does a Class A GFCI trip?

  • (a) 5 mA
  • (b) 15 mA
  • (c) 30 mA
  • (d) 100 mA

Answer: (a) 5 mA — a Class A GFCI trips at 5 mA of ground-fault current, fast enough to protect people from a lethal shock.

Q2. Within what distance of a sink or other water source does the NEC require GFCI protection for receptacles?

  • (a) 3 ft
  • (b) 6 ft
  • (c) 10 ft
  • (d) 12 ft

Answer: (b) 6 ft — NEC 210.8 requires GFCI protection for receptacles within 6 ft of a sink, bathtub, shower or other water source.

Q3. Which device protects people against electric shock?

  • (a) AFCI
  • (b) GFCI
  • (c) A standard circuit breaker
  • (d) A surge protector

Answer: (b) GFCI — a GFCI detects current leaking to ground through a person and trips in milliseconds; an AFCI protects against fire-causing arcs.

Q4. In which room did the NEC first require AFCI protection for branch circuits?

  • (a) Kitchen
  • (b) Bathroom
  • (c) Bedroom
  • (d) Garage

Answer: (c) Bedroom — NEC 210.12 first required AFCI protection for bedroom branch circuits, and later editions extended it to living rooms, kitchens and laundry areas.

Q5. What kind of fault does an AFCI protect against?

  • (a) Overload
  • (b) A short circuit only
  • (c) An arcing fault that can start a fire
  • (d) A lightning strike

Answer: (c) An arcing fault that can start a fire — an AFCI detects the irregular current pattern of an arc, such as a damaged cord, and trips before the arc ignites surrounding material.

Q6. Which of these locations requires GFCI protection for its receptacles?

  • (a) A bedroom
  • (b) An outdoor receptacle
  • (c) A hallway
  • (d) A living room

Answer: (b) An outdoor receptacle — NEC 210.8 requires GFCI protection outdoors, in bathrooms, kitchens, garages, basements and crawl spaces, where shock risk is highest.

Q7. A 30 mA RCD (RCCB) is common in IEC-based installations. How does its trip level compare with a US Class A GFCI?

  • (a) They are the same
  • (b) The 30 mA device is six times less sensitive — it protects equipment and against fire, while the 5 mA GFCI protects people
  • (c) The 30 mA device is more sensitive
  • (d) The 30 mA device trips faster

Answer: (b) The 30 mA device is six times less sensitive — it protects equipment and against fire, while the 5 mA GFCI protects people — 30 ÷ 5 = 6, so the GFCI trips at one-sixth of the current.

Q8. Besides bedrooms, which area did later NEC editions add to AFCI requirements?

  • (a) The garage only
  • (b) Living rooms, kitchens and laundry areas
  • (c) The attic only
  • (d) Outdoor receptacles

Answer: (b) Living rooms, kitchens and laundry areas — NEC 210.12 now requires AFCI protection in most dwelling rooms, not just bedrooms.

Q9. How often should a GFCI receptacle be tested with its TEST button?

  • (a) Once a year
  • (b) Once a month
  • (c) Once every five years
  • (d) Never — it is self-testing

Answer: (b) Once a month — manufacturers and the NEC recommend monthly testing so a failed GFCI is found before it is needed in an emergency.

Q10. A kitchen circuit needs both GFCI and AFCI protection. What is the correct solution?

  • (a) A standard breaker is enough
  • (b) A dual-function AFCI/GFCI breaker or receptacle
  • (c) Two standard breakers in parallel
  • (d) A larger breaker

Answer: (b) A dual-function AFCI/GFCI breaker or receptacle — one device cannot replace the other, so a dual-function device provides both shock and arc-fault protection on the same circuit.