NEC Code MCQs — Set 2

10 practice questions on NEC Article 210 branch circuits — receptacle spacing, kitchen, bathroom and laundry circuits.

Q1. Under NEC 210.52, what is the maximum distance from any point along a dwelling wall to a receptacle?

  • (a) 3 ft
  • (b) 6 ft
  • (c) 10 ft
  • (d) 12 ft

Answer: (b) 6 ft — no point along the floor line of a wall may be more than 6 ft from a receptacle outlet.

Q2. What is the maximum spacing between receptacles along a dwelling wall?

  • (a) 6 ft
  • (b) 8 ft
  • (c) 12 ft
  • (d) 18 ft

Answer: (c) 12 ft — with the 6 ft rule on each side, receptacles are at most 12 ft apart along a wall.

Q3. How many 20 A small-appliance branch circuits must a dwelling kitchen have at minimum?

  • (a) One
  • (b) Two
  • (c) Three
  • (d) Four

Answer: (b) Two — NEC 210.11(C)(1) requires at least two 20 A small-appliance branch circuits serving the kitchen, dining and pantry receptacles.

Q4. What is the minimum rating of the branch circuit serving a bathroom receptacle?

  • (a) 15 A
  • (b) 20 A
  • (c) 30 A
  • (d) 40 A

Answer: (b) 20 A — NEC 210.11(C)(3) requires at least one 20 A branch circuit for bathroom receptacles.

Q5. How many dedicated 20 A laundry branch circuits does a dwelling require?

  • (a) None
  • (b) One
  • (c) Two
  • (d) One per bedroom

Answer: (b) One — NEC 210.11(C)(2) requires at least one 20 A laundry branch circuit serving the laundry receptacles.

Q6. Along a kitchen countertop, what is the maximum distance from any point to a receptacle?

  • (a) 12 in (1 ft)
  • (b) 24 in (2 ft)
  • (c) 48 in (4 ft)
  • (d) 72 in (6 ft)

Answer: (b) 24 in (2 ft) — NEC 210.52(C)(1) requires that no point along the countertop wall be more than 24 in from a receptacle, so receptacles are at most 4 ft apart.

Q7. A hallway in a dwelling is 12 ft long. How many receptacles does the NEC require in it?

  • (a) None
  • (b) One
  • (c) Two
  • (d) Three

Answer: (b) One — NEC 210.52(H) requires at least one receptacle in a hallway 10 ft or longer.

Q8. Which of these appliances normally requires its own dedicated branch circuit?

  • (a) A table lamp
  • (b) A phone charger
  • (c) An electric range
  • (d) A ceiling fan

Answer: (c) An electric range — large fixed appliances such as electric ranges, water heaters and dryers are served by their own dedicated branch circuits, while lamps, chargers and fans share general-purpose circuits.

Q9. A floor receptacle counts toward the required wall receptacles if it is within what distance of the wall?

  • (a) 6 in
  • (b) 12 in
  • (c) 18 in
  • (d) 24 in

Answer: (c) 18 in — NEC 210.52(A)(3) allows a floor receptacle within 18 in of the wall to count as a required wall receptacle.

Q10. In a multiwire branch circuit, two ungrounded conductors share one neutral. What must be true of the two ungrounded conductors?

  • (a) They must be the same phase
  • (b) They must be on opposite phases (or legs) so the neutral carries only the unbalanced current
  • (c) They must both be 15 A
  • (d) They must not have a breaker

Answer: (b) They must be on opposite phases (or legs) so the neutral carries only the unbalanced current — on the same phase the neutral would carry the sum of both currents and could overload.