Motor Starter MCQs — Set 8
10 practice questions on the rotor resistance starter for slip-ring (wound-rotor) motors — external resistance, high starting torque, and slip — with answers and explanations.
Q1. A rotor resistance starter can only be used with which type of motor?
- (a) Squirrel-cage induction motor
- (b) Wound-rotor (slip-ring) induction motor
- (c) Single-phase capacitor motor
- (d) Synchronous motor
Answer: (b) Wound-rotor (slip-ring) induction motor — only a wound rotor brings its windings out for external resistance to be connected.
Q2. Where is the extra resistance connected in a rotor resistance starter?
- (a) In series with the stator windings
- (b) In series with the rotor windings, through slip rings and brushes
- (c) Across the supply lines
- (d) In the contactor coil circuit
Answer: (b) In series with the rotor windings, through slip rings and brushes — the rotor circuit is accessible only through the slip rings.
Q3. What does adding resistance to the rotor circuit do at starting?
- (a) It increases the starting current and reduces the starting torque
- (b) It reduces the starting current and increases the starting torque
- (c) It has no effect on current or torque
- (d) It reverses the direction of rotation
Answer: (b) It reduces the starting current and increases the starting torque — the added resistance improves the rotor power factor at standstill, so more of the rotor current produces torque.
Q4. Maximum starting torque is obtained when the rotor resistance is:
- (a) Zero
- (b) Equal to the rotor reactance at standstill
- (c) Ten times the rotor reactance
- (d) Infinite
Answer: (b) Equal to the rotor reactance at standstill — at that value the rotor power factor is at its best for torque production.
Q5. What happens to the external resistance as the motor runs up to speed?
- (a) It is increased step by step
- (b) It is cut out in steps until the rotor is short-circuited
- (c) It stays in circuit for the whole run
- (d) It is transferred to the stator
Answer: (b) It is cut out in steps until the rotor is short-circuited — once running, the resistance would only waste power as heat and increase slip.
Q6. A motor has a synchronous speed of 1500 rpm and a rotor speed of 1440 rpm. What is the slip?
- (a) 2%
- (b) 4%
- (c) 6%
- (d) 10%
Answer: (b) 4% — slip = (1500 − 1440) ÷ 1500 = 60 ÷ 1500 = 0.04, or 4%.
Q7. A motor has a synchronous speed of 1500 rpm and a rotor speed of 1470 rpm. What is the slip?
- (a) 1%
- (b) 2%
- (c) 3%
- (d) 5%
Answer: (b) 2% — slip = (1500 − 1470) ÷ 1500 = 30 ÷ 1500 = 0.02, or 2%.
Q8. Which load is a rotor resistance starter best suited to?
- (a) A small fan that starts unloaded
- (b) Heavy loads needing high starting torque, such as cranes, mills and hoists
- (c) A domestic washing machine
- (d) A clock motor
Answer: (b) Heavy loads needing high starting torque, such as cranes, mills and hoists — the rotor resistance starter gives high torque with a smooth, stepped start.
Q9. What is a disadvantage of the slip-ring motor and its rotor resistance starter?
- (a) It cannot develop any starting torque
- (b) The slip rings and brushes need regular maintenance, and the set-up costs more than a cage motor with a DOL or star-delta starter
- (c) It draws more starting current than a DOL start
- (d) It can only run at synchronous speed
Answer: (b) The slip rings and brushes need regular maintenance, and the set-up costs more than a cage motor with a DOL or star-delta starter — that is why cage motors dominate where high starting torque is not needed.
Q10. At the instant of starting, the slip of an induction motor is:
- (a) 0
- (b) 0.5
- (c) 1
- (d) Negative
Answer: (c) 1 — at standstill the rotor speed is zero, so slip = (Ns − 0) ÷ Ns = 1, or 100%.
Also read: DC Motor Calculator | All MCQ Topics