Motor Starter MCQs — Set 8

10 practice questions on the rotor resistance starter for slip-ring (wound-rotor) motors — external resistance, high starting torque, and slip — with answers and explanations.

Q1. A rotor resistance starter can only be used with which type of motor?

  • (a) Squirrel-cage induction motor
  • (b) Wound-rotor (slip-ring) induction motor
  • (c) Single-phase capacitor motor
  • (d) Synchronous motor

Answer: (b) Wound-rotor (slip-ring) induction motor — only a wound rotor brings its windings out for external resistance to be connected.

Q2. Where is the extra resistance connected in a rotor resistance starter?

  • (a) In series with the stator windings
  • (b) In series with the rotor windings, through slip rings and brushes
  • (c) Across the supply lines
  • (d) In the contactor coil circuit

Answer: (b) In series with the rotor windings, through slip rings and brushes — the rotor circuit is accessible only through the slip rings.

Q3. What does adding resistance to the rotor circuit do at starting?

  • (a) It increases the starting current and reduces the starting torque
  • (b) It reduces the starting current and increases the starting torque
  • (c) It has no effect on current or torque
  • (d) It reverses the direction of rotation

Answer: (b) It reduces the starting current and increases the starting torque — the added resistance improves the rotor power factor at standstill, so more of the rotor current produces torque.

Q4. Maximum starting torque is obtained when the rotor resistance is:

  • (a) Zero
  • (b) Equal to the rotor reactance at standstill
  • (c) Ten times the rotor reactance
  • (d) Infinite

Answer: (b) Equal to the rotor reactance at standstill — at that value the rotor power factor is at its best for torque production.

Q5. What happens to the external resistance as the motor runs up to speed?

  • (a) It is increased step by step
  • (b) It is cut out in steps until the rotor is short-circuited
  • (c) It stays in circuit for the whole run
  • (d) It is transferred to the stator

Answer: (b) It is cut out in steps until the rotor is short-circuited — once running, the resistance would only waste power as heat and increase slip.

Q6. A motor has a synchronous speed of 1500 rpm and a rotor speed of 1440 rpm. What is the slip?

  • (a) 2%
  • (b) 4%
  • (c) 6%
  • (d) 10%

Answer: (b) 4% — slip = (1500 − 1440) ÷ 1500 = 60 ÷ 1500 = 0.04, or 4%.

Q7. A motor has a synchronous speed of 1500 rpm and a rotor speed of 1470 rpm. What is the slip?

  • (a) 1%
  • (b) 2%
  • (c) 3%
  • (d) 5%

Answer: (b) 2% — slip = (1500 − 1470) ÷ 1500 = 30 ÷ 1500 = 0.02, or 2%.

Q8. Which load is a rotor resistance starter best suited to?

  • (a) A small fan that starts unloaded
  • (b) Heavy loads needing high starting torque, such as cranes, mills and hoists
  • (c) A domestic washing machine
  • (d) A clock motor

Answer: (b) Heavy loads needing high starting torque, such as cranes, mills and hoists — the rotor resistance starter gives high torque with a smooth, stepped start.

Q9. What is a disadvantage of the slip-ring motor and its rotor resistance starter?

  • (a) It cannot develop any starting torque
  • (b) The slip rings and brushes need regular maintenance, and the set-up costs more than a cage motor with a DOL or star-delta starter
  • (c) It draws more starting current than a DOL start
  • (d) It can only run at synchronous speed

Answer: (b) The slip rings and brushes need regular maintenance, and the set-up costs more than a cage motor with a DOL or star-delta starter — that is why cage motors dominate where high starting torque is not needed.

Q10. At the instant of starting, the slip of an induction motor is:

  • (a) 0
  • (b) 0.5
  • (c) 1
  • (d) Negative

Answer: (c) 1 — at standstill the rotor speed is zero, so slip = (Ns − 0) ÷ Ns = 1, or 100%.