Electrical Maintenance MCQs — Set 10

10 practice questions on condition monitoring and fault diagnosis — finding problems early and deciding what to do — with answers and explanations.

Q1. What can vibration analysis detect in rotating machines?

  • (a) The colour of the paint
  • (b) Bearing wear, imbalance and misalignment before they cause failure
  • (c) The insulation resistance of the windings
  • (d) The voltage of the supply

Answer: (b) Bearing wear, imbalance and misalignment before they cause failure — a vibration sensor picks up changes in the machine’s vibration pattern long before the damage can be seen or heard.

Q2. Why is oil analysis carried out on large transformers?

  • (a) To check the colour of the oil only
  • (b) To detect overheating, contamination and arcing inside the transformer from changes in the oil
  • (c) To increase the transformer’s output
  • (d) To reduce the amount of oil needed

Answer: (b) To detect overheating, contamination and arcing inside the transformer from changes in the oil — dissolved gases and particles in the oil reveal faults developing inside a sealed transformer.

Q3. A 50 W device is left switched on for 8 hours. How much energy does it waste?

  • (a) 0.04 kWh
  • (b) 0.4 kWh
  • (c) 4 kWh
  • (d) 400 kWh

Answer: (b) 0.4 kWh — energy = power × time = 50 × 8 = 400 Wh = 0.4 kWh.

Q4. When diagnosing an electrical fault, what is the best first step?

  • (a) Replace the most expensive part immediately
  • (b) Gather the symptoms and check the simplest, most likely causes first
  • (c) Switch the supply on and off repeatedly
  • (d) Ignore the fault and hope it goes away

Answer: (b) Gather the symptoms and check the simplest, most likely causes first — a loose connection or a tripped breaker is far more common than a rare internal failure, so checking the simple things first saves time.

Q5. An intermittent fault comes and goes without a clear pattern. What should be checked first?

  • (a) Loose connections and damaged cables that move or heat up
  • (b) The colour of the equipment
  • (c) The building’s water supply
  • (d) The age of the light bulbs

Answer: (a) Loose connections and damaged cables that move or heat up — a loose terminal makes and breaks contact as it heats, cools or vibrates, which is the classic cause of a fault that comes and goes.

Q6. What is partial discharge in electrical insulation?

  • (a) A complete breakdown of the insulation
  • (b) Small electrical discharges inside voids or defects in the insulation, an early warning of insulation failure
  • (c) The normal current flowing through a cable
  • (d) A discharge of the battery

Answer: (b) Small electrical discharges inside voids or defects in the insulation, an early warning of insulation failure — partial discharge slowly erodes the insulation, so detecting it early allows planned repair before a full breakdown.

Q7. A motor’s running current is slowly rising over several weeks while its load stays the same. What does this suggest?

  • (a) The motor is becoming more efficient
  • (b) A developing fault, such as bearing wear, winding trouble or a dragging load
  • (c) The supply voltage is too high
  • (d) Nothing, current always rises with time

Answer: (b) A developing fault, such as bearing wear, winding trouble or a dragging load — a rising current trend at constant load means the motor is working harder, which points to a problem getting worse.

Q8. Why is the temperature of a motor trended (recorded regularly) rather than checked once?

  • (a) To use up the thermometer
  • (b) Because a gradual rise over time reveals a developing fault before the motor overheats and fails
  • (c) Because a single reading is always too high
  • (d) To prove the motor is cold

Answer: (b) Because a gradual rise over time reveals a developing fault before the motor overheats and fails — a trend shows change, while one reading alone cannot tell whether the temperature is normal for that motor.

Q9. When deciding between repairing an old motor and replacing it, what should be considered?

  • (a) Only the colour of the new motor
  • (b) Repair cost, the motor’s age and condition, energy efficiency and availability of parts
  • (c) Only the weight of the motor
  • (d) The repair should always be chosen, whatever the cost

Answer: (b) Repair cost, the motor’s age and condition, energy efficiency and availability of parts — a very old, inefficient motor with worn parts may cost more to keep repairing than a new, efficient replacement.

Q10. After a repair is finished, what must be done before the equipment is returned to service?

  • (a) Nothing, it can be switched on straight away
  • (b) Inspect and test it to verify the repair, then check that it runs correctly
  • (c) Paint it a different colour
  • (d) Leave it switched off for a week

Answer: (b) Inspect and test it to verify the repair, then check that it runs correctly — testing after repair proves the fault is fixed and that no new problem was introduced before the equipment goes back into use.

Also read: Power and Energy MCQs | All MCQ Topics