Electrical Maintenance MCQs — Set 1

10 practice questions on the types of electrical maintenance — preventive, corrective, predictive and breakdown — with answers and explanations.

Q1. What is preventive maintenance?

  • (a) Repairing equipment only after it has failed
  • (b) Planned work carried out at regular intervals to stop failures happening
  • (c) Replacing equipment with a newer model
  • (d) Monitoring equipment continuously with sensors

Answer: (b) Planned work carried out at regular intervals to stop failures happening — preventive maintenance is scheduled in advance, such as cleaning and tightening a panel every six months, so faults are caught before they cause a breakdown.

Q2. What is corrective maintenance?

  • (a) Maintenance done on a fixed calendar schedule
  • (b) Maintenance based on sensor readings and trends
  • (c) Repair work carried out after equipment has failed
  • (d) Maintenance done by the machine operator each shift

Answer: (c) Repair work carried out after equipment has failed — corrective maintenance restores failed equipment to working order, for example replacing a burnt-out motor contactor.

Q3. What is predictive maintenance?

  • (a) Replacing parts at fixed time intervals regardless of condition
  • (b) Using condition monitoring, such as vibration or temperature readings, to predict failure before it happens
  • (c) Repairing equipment only when it stops working
  • (d) Doing all maintenance during a yearly shutdown

Answer: (b) Using condition monitoring, such as vibration or temperature readings, to predict failure before it happens — predictive maintenance acts on the measured condition of the equipment, not on the calendar.

Q4. What does breakdown maintenance mean?

  • (a) A detailed inspection carried out every month
  • (b) Running equipment until it fails and then repairing it
  • (c) Testing insulation resistance once a year
  • (d) Lubricating bearings on a fixed schedule

Answer: (b) Running equipment until it fails and then repairing it — breakdown maintenance, also called run-to-failure, has no planned action before the failure occurs.

Q5. Which of the following is an example of predictive maintenance?

  • (a) Replacing a lamp every 6 months whether it works or not
  • (b) Carrying out a thermal (infrared) scan of a panel and acting on a hot connection
  • (c) Repairing a pump after its motor burns out
  • (d) Cleaning a distribution board on the first Monday of each month

Answer: (b) Carrying out a thermal (infrared) scan of a panel and acting on a hot connection — the scan measures the actual condition of the equipment and the repair is triggered by what it finds.

Q6. What is Total Productive Maintenance (TPM)?

  • (a) Maintenance done only by outside contractors
  • (b) A system where operators take part in routine care such as cleaning, inspection and lubrication
  • (c) Maintenance that is only done when equipment breaks down
  • (d) A method of testing insulation with a megger

Answer: (b) A system where operators take part in routine care such as cleaning, inspection and lubrication — TPM shares basic maintenance tasks with the people who run the equipment every day, so small problems are spotted early.

Q7. For a critical transformer that would shut down a whole factory if it failed, which maintenance approach is most suitable?

  • (a) Breakdown maintenance
  • (b) No maintenance at all
  • (c) Planned preventive and predictive maintenance
  • (d) Corrective maintenance only

Answer: (c) Planned preventive and predictive maintenance — for critical equipment the cost of an unexpected failure is far higher than the cost of planned inspections, testing and condition monitoring.

Q8. Breakdown (run-to-failure) maintenance is most acceptable for which item?

  • (a) The main incoming circuit breaker of a hospital
  • (b) A cheap, non-critical indicator lamp that is easy to replace
  • (c) A fire alarm panel
  • (d) An emergency lighting system

Answer: (b) A cheap, non-critical indicator lamp that is easy to replace — run-to-failure is only sensible where failure is cheap, safe and causes no serious disruption.

Q9. What triggers a task under condition-based maintenance?

  • (a) The date on the calendar
  • (b) The measured condition of the equipment, such as temperature, vibration or insulation value
  • (c) The equipment manufacturer’s warranty expiry
  • (d) A breakdown that has already happened

Answer: (b) The measured condition of the equipment, such as temperature, vibration or insulation value — the work is done when a measurement shows it is needed, not simply because a date has arrived.

Q10. What is the main disadvantage of relying only on corrective maintenance?

  • (a) It needs too many spare parts in stock
  • (b) Failures happen without warning, causing unplanned downtime and often higher repair costs
  • (c) It requires expensive test instruments
  • (d) It makes the equipment last too long

Answer: (b) Failures happen without warning, causing unplanned downtime and often higher repair costs — an unplanned failure can stop production, damage other parts and need emergency call-outs.

Also read: AFCI Breaker Keeps Tripping | All MCQ Topics