Lightning Protection MCQs — Set 2

10 practice questions on air terminals and lightning rods, with answers and explanations. Work each one out before checking the answer.

Q1. Who is credited with inventing the lightning rod?

  • (a) Thomas Edison
  • (b) Nikola Tesla
  • (c) Benjamin Franklin
  • (d) Michael Faraday

Answer: (c) Benjamin Franklin — Franklin showed that a pointed metal rod connected to the earth could safely intercept a lightning strike, and the idea is still the basis of modern air terminals.

Q2. What is the main purpose of an air terminal on a building?

  • (a) To stop lightning from forming
  • (b) To provide a preferred attachment point so lightning strikes the terminal, not the building
  • (c) To store the lightning’s energy
  • (d) To measure the lightning current

Answer: (b) To provide a preferred attachment point so lightning strikes the terminal, not the building — the air terminal intercepts the strike and hands the current to the down conductor.

Q3. Which material is most commonly used for air terminals?

  • (a) Plastic
  • (b) Iron
  • (c) Copper
  • (d) Rubber

Answer: (c) Copper — copper is highly conductive, withstands the heat of a strike, and resists corrosion in the open air.

Q4. Why is the tip of an air terminal usually pointed?

  • (a) To look decorative
  • (b) To concentrate the electric field and encourage an upward streamer to start there
  • (c) To pierce the cloud
  • (d) To reduce wind resistance

Answer: (b) To concentrate the electric field and encourage an upward streamer to start there — a sharp tip strengthens the local electric field, so the streamer launches from the rod rather than from the roof below it.

Q5. Where should air terminals be placed on a building?

  • (a) At ground level, near the entrance
  • (b) Only on the south side
  • (c) At the highest points — ridges, chimneys, parapets and corners
  • (d) Inside the roof space

Answer: (c) At the highest points — ridges, chimneys, parapets and corners — these are the points lightning is most likely to attach to, so the terminals must cover them.

Q6. What is an ESE (early streamer emission) air terminal?

  • (a) A terminal that claims to launch its upward streamer earlier than a plain rod
  • (b) A terminal made only of aluminium
  • (c) A terminal that stores charge in a battery
  • (d) A terminal buried in the earth

Answer: (a) A terminal that claims to launch its upward streamer earlier than a plain rod — ESE terminals use an electronic trigger, but their claimed larger protection radius is disputed and they must still connect to down conductors and earth electrodes.

Q7. What happens if an air terminal is installed but not connected to a down conductor?

  • (a) It still protects the building
  • (b) It is useless and dangerous, because the strike has no safe path to earth
  • (c) It only protects half the building
  • (d) It works as a surge protector

Answer: (b) It is useless and dangerous, because the strike has no safe path to earth — an unconnected rod invites the strike and then lets the current find its own destructive route through the building.

Q8. Can a metal roof itself act as the air termination system?

  • (a) No, metal roofs can never be used
  • (b) Yes, if the metal is thick enough, continuous and properly bonded, it can serve as a natural air termination
  • (c) Only if the roof is painted
  • (d) Only on single-storey buildings

Answer: (b) Yes, if the metal is thick enough, continuous and properly bonded, it can serve as a natural air termination — a suitable metal roof can be used as a natural component of the lightning protection system.

Q9. Why are air terminals usually made of copper or aluminium rather than steel?

  • (a) Steel is too expensive
  • (b) Copper and aluminium combine high conductivity with good corrosion resistance
  • (c) Steel attracts more lightning
  • (d) Steel cannot be sharpened

Answer: (b) Copper and aluminium combine high conductivity with good corrosion resistance — the terminal must carry tens of kiloamperes and survive years of weather without rusting away.

Q10. What is a finial in lightning protection?

  • (a) The earth electrode at the base of the system
  • (b) The pointed rod at the top of an air terminal
  • (c) The test joint on a down conductor
  • (d) The surge protector at the main board

Answer: (b) The pointed rod at the top of an air terminal — the finial is the vertical rod whose tip is the intended strike attachment point.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics