IEC Standards MCQs — Set 6
10 practice questions on IEC 62305, the standard for protection against lightning. Work each one out before checking the answer.
Q1. What does the IEC 62305 series cover?
- (a) Low-voltage cable sizing
- (b) Protection against lightning
- (c) EMC of household appliances
- (d) Energy efficiency of motors
Answer: (b) Protection against lightning — IEC 62305 covers risk assessment, physical protection of structures and protection of electrical systems inside them.
Q2. Which part of IEC 62305 covers risk management?
- (a) 62305-1
- (b) 62305-2
- (c) 62305-3
- (d) 62305-4
Answer: (b) 62305-2 — this part explains how to assess the risk from lightning and decide whether protection is needed and to what level.
Q3. Which part of IEC 62305 covers physical damage to structures and life hazard?
- (a) 62305-1
- (b) 62305-2
- (c) 62305-3
- (d) 62305-4
Answer: (c) 62305-3 — this part covers air-termination systems, down-conductors, earth-termination systems and separation distances.
Q4. Which part of IEC 62305 covers electrical and electronic systems within a structure?
- (a) 62305-1
- (b) 62305-2
- (c) 62305-3
- (d) 62305-4
Answer: (d) 62305-4 — this part covers protection of electrical and electronic systems inside the structure, including surge protective devices (SPDs).
Q5. In the rolling sphere method, what is the sphere radius for Lightning Protection Level I (LPL I)?
- (a) 10 m
- (b) 20 m
- (c) 30 m
- (d) 60 m
Answer: (b) 20 m — LPL I uses the smallest rolling sphere radius of 20 m, giving the highest level of protection.
Q6. In the rolling sphere method, what is the sphere radius for Lightning Protection Level II (LPL II)?
- (a) 20 m
- (b) 30 m
- (c) 45 m
- (d) 60 m
Answer: (b) 30 m — LPL II uses a 30 m rolling sphere radius, between LPL I (20 m) and LPL III (45 m).
Q7. In the rolling sphere method, what is the sphere radius for Lightning Protection Level IV (LPL IV)?
- (a) 20 m
- (b) 30 m
- (c) 45 m
- (d) 60 m
Answer: (d) 60 m — LPL IV uses the largest rolling sphere radius of 60 m, giving the lowest level of protection in the series.
Q8. What test waveform is used for a Class I surge protective device (SPD)?
- (a) 1.2/50 µs
- (b) 8/20 µs
- (c) 10/350 µs
- (d) 5/50 ns
Answer: (c) 10/350 µs — Class I SPDs are tested with the 10/350 µs impulse current waveform that represents a direct lightning strike.
Q9. What test waveform is used for a Class II surge protective device (SPD)?
- (a) 1.2/50 µs
- (b) 8/20 µs
- (c) 10/350 µs
- (d) 5/50 ns
Answer: (b) 8/20 µs — Class II SPDs are tested with the 8/20 µs impulse current waveform that represents an indirect lightning surge.
Q10. What does IEC 62305-1 cover?
- (a) Risk management calculations
- (b) General principles of protection against lightning
- (c) Surge protective device installation
- (d) Periodic inspection of lightning systems
Answer: (b) General principles of protection against lightning — Part 1 introduces the lightning threat, the protection levels and the structure of the whole 62305 series.
Also read: Electrical Safety MCQs | All MCQ Topics