IEC Standards MCQs — Set 5
10 practice questions on IEC 61000, the standard for electromagnetic compatibility (EMC). Work each one out before checking the answer.
Q1. What does the IEC 61000 series cover?
- (a) Cable current ratings
- (b) Electromagnetic compatibility (EMC)
- (c) Lightning protection of buildings
- (d) Battery charging times
Answer: (b) Electromagnetic compatibility (EMC) — IEC 61000 sets the limits and test methods so equipment neither disturbs other equipment nor is disturbed by it.
Q2. Which part of IEC 61000 sets harmonic current limits for equipment drawing up to 16 A per phase?
- (a) IEC 61000-3-2
- (b) IEC 61000-3-3
- (c) IEC 61000-4-2
- (d) IEC 61000-4-5
Answer: (a) IEC 61000-3-2 — this part limits the harmonic currents that equipment rated up to 16 A per phase may inject into the public supply.
Q3. Which part of IEC 61000 covers the electrostatic discharge (ESD) immunity test?
- (a) IEC 61000-4-2
- (b) IEC 61000-4-3
- (c) IEC 61000-4-4
- (d) IEC 61000-4-6
Answer: (a) IEC 61000-4-2 — this part tests whether equipment keeps working when an operator touches it and a static discharge occurs.
Q4. In the IEC 61000-4-2 ESD test, what is the contact discharge voltage at severity level 4?
- (a) 2 kV
- (b) 4 kV
- (c) 8 kV
- (d) 15 kV
Answer: (c) 8 kV — at level 4 the test applies an 8 kV contact discharge (and 15 kV air discharge) to the equipment.
Q5. Which part of IEC 61000 covers the surge immunity test?
- (a) IEC 61000-4-2
- (b) IEC 61000-4-4
- (c) IEC 61000-4-5
- (d) IEC 61000-4-11
Answer: (c) IEC 61000-4-5 — this part tests immunity to surges caused by lightning or switching, using a surge generator.
Q6. What is the standard voltage waveform used in the IEC 61000-4-5 surge test?
- (a) 5/50 ns
- (b) 1.2/50 µs
- (c) 8/20 µs
- (d) 10/350 µs
Answer: (b) 1.2/50 µs — the surge generator produces a 1.2/50 µs open-circuit voltage wave (with an 8/20 µs short-circuit current wave).
Q7. Which part of IEC 61000 covers electrical fast transient / burst immunity?
- (a) IEC 61000-4-2
- (b) IEC 61000-4-3
- (c) IEC 61000-4-4
- (d) IEC 61000-4-5
Answer: (c) IEC 61000-4-4 — this part tests immunity to fast bursts of short pulses caused by switching inductive loads or relay contacts.
Q8. Which part of IEC 61000 covers radiated radio-frequency electromagnetic field immunity?
- (a) IEC 61000-4-2
- (b) IEC 61000-4-3
- (c) IEC 61000-4-4
- (d) IEC 61000-4-11
Answer: (b) IEC 61000-4-3 — this part tests equipment in a radiated radio-frequency field, such as the field from a nearby transmitter or mobile phone.
Q9. Which part of IEC 61000 covers voltage dips, short interruptions and voltage variations?
- (a) IEC 61000-3-2
- (b) IEC 61000-4-3
- (c) IEC 61000-4-5
- (d) IEC 61000-4-11
Answer: (d) IEC 61000-4-11 — this part tests how equipment behaves when the supply voltage dips briefly or is interrupted for a short time.
Q10. EMC has two sides. What are they?
- (a) Voltage and current
- (b) Emission and immunity
- (c) AC and DC
- (d) Conducted and wireless
Answer: (b) Emission and immunity — equipment must limit the electromagnetic disturbance it emits and must be immune enough to keep working in its expected environment.