Home Automation MCQs — Set 2

10 practice questions on smart switches and relays — load ratings, the 80% rule, contacts, neutral wires and dimmers — with answers and explanations.

Q1. A smart relay is rated 10 A at 230 V. What is the maximum load it can switch?

  • (a) 1,150 W
  • (b) 2,300 W
  • (c) 3,680 W
  • (d) 4,600 W

Answer: (b) 2,300 W — P = V × I = 230 × 10 = 2,300 W.

Q2. A smart switch is rated 16 A at 230 V. What is its maximum load?

  • (a) 2,300 W
  • (b) 2,944 W
  • (c) 3,680 W
  • (d) 1,840 W

Answer: (c) 3,680 W — P = V × I = 230 × 16 = 3,680 W.

Q3. A small relay is rated 5 A at 230 V. What load can it safely switch at most?

  • (a) 1,150 W
  • (b) 2,300 W
  • (c) 575 W
  • (d) 3,680 W

Answer: (a) 1,150 W — P = V × I = 230 × 5 = 1,150 W, so it suits only light loads such as lamps, not heaters.

Q4. For continuous loads, the safe limit is 80% of a relay’s rating. What is the safe continuous load of a 10 A relay at 230 V?

  • (a) 2,300 W
  • (b) 1,840 W
  • (c) 1,150 W
  • (d) 2,944 W

Answer: (b) 1,840 W — 80% of 10 A is 8 A, and 230 × 8 = 1,840 W.

Q5. What is the safe continuous load of a 16 A smart switch at 230 V under the 80% rule?

  • (a) 3,680 W
  • (b) 1,840 W
  • (c) 2,944 W
  • (d) 2,300 W

Answer: (c) 2,944 W — 80% of 16 A is 12.8 A, and 230 × 12.8 = 2,944 W.

Q6. A 3,000 W water heater runs on 230 V. Which smart switch rating is suitable for it?

  • (a) A 5 A switch
  • (b) A 10 A switch
  • (c) A 16 A switch
  • (d) Any switch, ratings do not matter

Answer: (c) A 16 A switch — the heater draws I = P ÷ V = 3,000 ÷ 230 = 13.04 A, which exceeds a 10 A switch but is within a 16 A switch.

Q7. What does a “normally open” (NO) relay contact mean?

  • (a) The contact is closed when the relay is off
  • (b) The contact is open when the relay is off and closes only when the relay is energised
  • (c) The relay has no contacts at all
  • (d) The relay is always damaged

Answer: (b) The contact is open when the relay is off and closes only when the relay is energised — NO contacts keep the load off until the relay is switched on.

Q8. Why do most smart switches need a neutral wire at the switch box?

  • (a) To make the light brighter
  • (b) Because the switch’s own electronics need continuous power, which the neutral wire provides
  • (c) To increase the Wi-Fi range
  • (d) To reduce the voltage to the bulb

Answer: (b) Because the switch’s own electronics need continuous power, which the neutral wire provides — without a neutral, the smart switch cannot stay powered when the light is off.

Q9. What does a smart dimmer do?

  • (a) It changes the colour of the walls
  • (b) It varies the brightness of a light by reducing the power delivered to it
  • (c) It switches the light on only at night
  • (d) It measures the room temperature

Answer: (b) It varies the brightness of a light by reducing the power delivered to it — dimming also saves energy because a dimmed lamp uses less power.

Q10. A 2,000 W room heater is plugged into a 10 A smart plug at 230 V. Is it safe for continuous use?

  • (a) Yes, because 2,000 W is less than 2,300 W
  • (b) No, because it draws about 8.7 A, above the 8 A continuous (80%) limit of the plug
  • (c) Yes, because heaters have no current
  • (d) No, because 2,000 W needs a 5 A plug

Answer: (b) No, because it draws about 8.7 A, above the 8 A continuous (80%) limit of the plug — I = 2,000 ÷ 230 = 8.7 A; the 80% continuous limit of a 10 A plug is 8 A, so a 16 A plug is the safe choice.