Heating Element MCQs — Set 10
10 mixed-review questions on heating elements — fault-finding, current checks, safe loading and element care.
Q1. A heater produces no heat. Which is the correct first step in fault-finding?
- (a) Replace the element immediately
- (b) Check the supply is present at the heater terminals, then check the thermostat and the element’s continuity
- (c) Fit a larger fuse
- (d) Pour water on the element
Answer: (b) Check the supply is present at the heater terminals, then check the thermostat and the element’s continuity — work from the supply inward so you find the real fault instead of guessing.
Q2. A clamp meter around one supply lead of a working 2 kW, 230 V heater should read about what?
- (a) 2.17 A
- (b) 4.35 A
- (c) 8.70 A
- (d) 13.04 A
Answer: (c) 8.70 A — I = P ÷ V = 2,000 ÷ 230 = 8.70 A; a much lower reading points to a faulty element or low voltage.
Q3. A 3 kW electric kettle runs on a 230 V supply. What current does it draw, and why does it need a heavy-duty socket?
- (a) 13.04 A — a normal 5 A socket would overheat
- (b) 6.52 A — any socket works
- (c) 3.26 A — it needs no special socket
- (d) 13.04 A — because the voltage is too high
Answer: (a) 13.04 A — a normal 5 A socket would overheat — I = 3,000 ÷ 230 = 13.04 A, so the kettle needs a 13 A or 16 A circuit.
Q4. The coil of a toaster glows red when working. What does a coil that stays dark while the toaster is switched on mean?
- (a) The toaster is working normally
- (b) No current is flowing — a broken element, failed switch or no supply
- (c) The bread is ready
- (d) The thermostat is set too high
Answer: (b) No current is flowing — a broken element, failed switch or no supply — a healthy toaster coil glows when current passes through it.
Q5. Why are heating element coils supported on ceramic beads or insulators inside a heater?
- (a) To make the coil heavier
- (b) To keep the hot coil from touching the metal body and to stop it sagging onto itself
- (c) To increase the current
- (d) To cool the coil with water
Answer: (b) To keep the hot coil from touching the metal body and to stop it sagging onto itself — ceramic withstands the heat and insulates the live coil from the casing.
Q6. Before replacing a geyser’s heating element, what must be done first?
- (a) Switch the geyser to maximum
- (b) Switch off the supply and drain the water from the tank
- (c) Fill the tank to the top
- (d) Remove the thermostat only
Answer: (b) Switch off the supply and drain the water from the tank — the element screws into the tank, so water would flood out and the live terminals must be dead before work starts.
Q7. A 750 W heater runs for 4 hours. How much energy does it use?
- (a) 0.75 kWh
- (b) 3 kWh
- (c) 1.5 kWh
- (d) 7.5 kWh
Answer: (b) 3 kWh — energy = power × time = 0.75 kW × 4 h = 3 kWh.
Q8. A 2,000 W room heater is plugged into a 230 V, 13 A socket. A second identical heater is plugged into the same socket via an adapter. What happens?
- (a) Both run normally
- (b) Total current is 17.4 A, overloading the 13 A socket, so the fuse blows or the socket overheats
- (c) Each heater draws only 4.35 A
- (d) The voltage doubles
Answer: (b) Total current is 17.4 A, overloading the 13 A socket, so the fuse blows or the socket overheats — one heater draws 2,000 ÷ 230 = 8.70 A, so two draw 17.4 A.
Q9. Why is ordinary iron wire not used for heating elements, even though it is cheap?
- (a) Iron wire has too high a resistance
- (b) Iron wire rusts and oxidises quickly at high temperature, so it burns out fast
- (c) Iron wire cannot carry current
- (d) Iron wire melts at 3,400 °C
Answer: (b) Iron wire rusts and oxidises quickly at high temperature, so it burns out fast — nichrome’s protective oxide layer is what gives it a long life.
Q10. How much heat energy does a 1 kW heating element produce in 10 minutes?
- (a) 60 kJ
- (b) 100 kJ
- (c) 600 kJ
- (d) 6,000 kJ
Answer: (c) 600 kJ — energy = power × time = 1,000 W × 600 s = 600,000 J = 600 kJ.
Also read: Watt Calculator | All MCQ Topics