Heating Element MCQs — Set 9
10 practice questions on advanced heating element topics — watt density, insulation, inrush current and three-phase heaters.
Q1. Watt density of a heating element means what?
- (a) The weight of the element per watt
- (b) The power in watts divided by the heated surface area
- (c) The current per watt
- (d) The voltage per centimetre of wire
Answer: (b) The power in watts divided by the heated surface area — high watt density means a hotter surface, which suits air heating but risks burnout in water or oil.
Q2. Magnesium oxide (MgO) is used inside tubular elements because it is which combination of properties?
- (a) Electrically conducting and thermally insulating
- (b) Electrically insulating and thermally conducting
- (c) Electrically and thermally insulating
- (d) Magnetic and heat resistant
Answer: (b) Electrically insulating and thermally conducting — MgO keeps the live coil away from the sheath while letting heat pass out to it.
Q3. When a cold heating element is first switched on, the current is briefly higher than normal. Why?
- (a) The supply voltage rises at switch-on
- (b) The element’s resistance is lower when cold and rises as it heats up
- (c) The thermostat is closed
- (d) The element draws extra current to start the fan
Answer: (b) The element’s resistance is lower when cold and rises as it heats up — this inrush current is brief and small in nichrome because its temperature coefficient is low.
Q4. Three identical heating elements are connected in delta across a three-phase supply, then reconnected in star at the same line voltage. How does the total power change?
- (a) It stays the same
- (b) It falls to one-third of the delta power
- (c) It triples
- (d) It falls to half
Answer: (b) It falls to one-third of the delta power — in star each element gets the phase voltage (line voltage ÷ √3), so power per element falls to one-third, and total power does the same.
Q5. Heat from a toaster coil reaches the bread mainly by which method?
- (a) Conduction through the air
- (b) Radiation — infrared rays travelling directly from the glowing coil
- (c) Convection only
- (d) Induction
Answer: (b) Radiation — infrared rays travelling directly from the glowing coil — the red-hot coil radiates heat straight onto the bread’s surface.
Q6. Why does frequent switching on and off shorten a heating element’s life?
- (a) It increases the supply voltage
- (b) Repeated heating and cooling expands and contracts the wire, causing fatigue and oxidation
- (c) It makes the resistance fall
- (d) It cools the element too much
Answer: (b) Repeated heating and cooling expands and contracts the wire, causing fatigue and oxidation — thermal cycling is a major cause of element failure.
Q7. Nichrome wire has a small positive temperature coefficient of resistance. What does this mean?
- (a) Its resistance falls as temperature rises
- (b) Its resistance rises slightly as temperature rises
- (c) Its resistance stays exactly constant
- (d) Its resistance becomes zero at high temperature
Answer: (b) Its resistance rises slightly as temperature rises — the change is small, so the element’s power stays almost stable when hot.
Q8. A heating element that is too long for its sheath sags when hot. Why is sagging a problem?
- (a) The wire may touch the sheath or a neighbouring turn, causing a short circuit or hot spot
- (b) The wire draws less current
- (c) The wire becomes magnetic
- (d) The wire stops radiating heat
Answer: (a) The wire may touch the sheath or a neighbouring turn, causing a short circuit or hot spot — elements are supported on ceramic insulators to prevent sagging.
Q9. A 1 kW element has a resistance of 52.9 Ω. If the supply voltage drops to 200 V, what power does it give out?
- (a) 1,000 W
- (b) 870 W
- (c) 756 W
- (d) 650 W
Answer: (c) 756 W — P = V² ÷ R = 200² ÷ 52.9 = 40,000 ÷ 52.9 = 756 W, so the heater runs noticeably cooler on low voltage.
Q10. How much heat energy does a 4 A current produce in a 20 Ω element in 60 seconds?
- (a) 4.8 kJ
- (b) 9.6 kJ
- (c) 19.2 kJ
- (d) 38.4 kJ
Answer: (c) 19.2 kJ — H = I²Rt = 4² × 20 × 60 = 16 × 20 × 60 = 19,200 J = 19.2 kJ.