Heating Element MCQs — Set 6

10 practice questions on heating element safety — earthing, RCCB protection, circuit sizing and overheat cut-outs.

Q1. Why must the metal body of a water geyser or room heater be earthed?

  • (a) To make the water heat faster
  • (b) So a fault current flows to earth and trips the breaker instead of giving a shock to anyone touching the body
  • (c) To reduce the electricity bill
  • (d) To increase the element’s resistance

Answer: (b) So a fault current flows to earth and trips the breaker instead of giving a shock to anyone touching the body — earthing gives fault current a safe low-resistance path.

Q2. An RCCB rated at 30 mA protects a heater circuit. At what leakage current will it trip?

  • (a) 30 A
  • (b) 300 mA
  • (c) 30 mA
  • (d) 3 A

Answer: (c) 30 mA — the RCCB trips when the difference between live and neutral current exceeds 30 mA, the level that protects people from shock.

Q3. A heater is marked Class II (double insulated) with a square-in-square symbol. What does this mean?

  • (a) It must be earthed
  • (b) It has two layers of insulation and needs no earth connection
  • (c) It has two heating elements
  • (d) It runs on two voltages

Answer: (b) It has two layers of insulation and needs no earth connection — double insulation replaces earthing as the shock protection.

Q4. A 2 kW room heater runs on a 230 V supply. What current does it draw?

  • (a) 4.35 A
  • (b) 8.7 A
  • (c) 17.4 A
  • (d) 2 A

Answer: (b) 8.7 A — I = P ÷ V = 2,000 ÷ 230 = 8.7 A.

Q5. A 5 kW heater runs on a 230 V supply at 0.9 power factor. What current does it draw, and what size MCB is suitable?

  • (a) 24.2 A — a 32 A MCB
  • (b) 19.6 A — a 20 A MCB
  • (c) 24.2 A — a 25 A MCB
  • (d) 21.7 A — a 16 A MCB

Answer: (a) 24.2 A — a 32 A MCB — I = P ÷ (V × pf) = 5,000 ÷ (230 × 0.9) = 24.2 A, so the next standard size above it, 32 A, is used.

Q6. A room heater has a tip-over switch. What does it do?

  • (a) It increases the heat when the heater falls over
  • (b) It switches the heater off if the heater is knocked over, preventing a fire
  • (c) It changes the thermostat setting
  • (d) It earths the heater

Answer: (b) It switches the heater off if the heater is knocked over, preventing a fire — a fallen heater could set curtains or carpet alight.

Q7. Why must an immersion heater element always be fully submerged before switching on?

  • (a) To save electricity
  • (b) Because the water carries the heat away; in air the element overheats and burns out
  • (c) Because the thermostat only works under water
  • (d) Because the element cannot glow in air

Answer: (b) Because the water carries the heat away; in air the element overheats and burns out — dry firing destroys an immersion element in seconds.

Q8. What is the danger of connecting a 230 V heating element to a 400 V supply?

  • (a) It will heat more slowly
  • (b) Power rises with the square of voltage, so the element will overheat and burn out, possibly causing a fire
  • (c) It will draw less current
  • (d) Nothing — elements work on any voltage

Answer: (b) Power rises with the square of voltage, so the element will overheat and burn out, possibly causing a fire — at 400 V the power would be (400 ÷ 230)² ≈ 3 times the rated power.

Q9. Why should flammable materials be kept away from a portable room heater?

  • (a) They reduce the heater’s efficiency
  • (b) The hot element or hot air can ignite curtains, bedding or paper
  • (c) They trip the RCCB
  • (d) They damage the thermostat

Answer: (b) The hot element or hot air can ignite curtains, bedding or paper — heaters must have clear space around them.

Q10. A heater’s overheat cut-out trips repeatedly. What is the correct action?

  • (a) Bypass the cut-out so the heater keeps running
  • (b) Find and fix the cause — blocked air vents, failed fan or faulty thermostat — before using it again
  • (c) Fit a larger fuse
  • (d) Move the heater closer to the wall

Answer: (b) Find and fix the cause — blocked air vents, failed fan or faulty thermostat — before using it again — bypassing a safety device can cause a fire.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics